7.60
External Tool - Remote Desktop Service. Another instance of zenVNC is already running.
Summary It may occur that after restarting of your PC an Information-Box pop ups concerning ‘Another instance of zenVNC is already running’. The process ‘zenVNCSrv.exe’ started twice in that case. Beside the Information-Box it will also displayed at ...
zenon Editor – macro toolbar improvement.
Summary At the zenon Editor the macro toolbar does not show which of the mutually exclusive states (all macros, vba macros, vsta macros) is active. DescriptionAt the zenon Editor the macro toolbar does not show which of the mutually exclusive ...
By temporary login and value changes via keyboard screen the CEL stores entry with user SYSTEM instead the logged-in.
Summary If you change the value via the keyboard screen (property: Write Set Value -> Use screen Keyboard and Choose a screen) and use the temporary login, then as user it is SYSTEM in the CEL displayed and not the logged-in user. CEL entries about ...
CEL filtering by Alarm Areas always displays system messages.
Summary When you filter events in CEL screen and use filtering by alarm area also the system messages are displayed, despite that option ‘Always display system messages in list’ is deactivated. If you use filtering by alarm/event groups or ...
On touch-devices there is a delay in the visual response of pressed buttons by executing commands
Summary Command Processing on touch-devices: there is a delay in the visual response of pressed buttons on executing commands. DescriptionCommand Processing on touch-devices: there is a delay in the visual response of pressed buttons on executing ...
In command group configured screen is not included in XML export and cannot be set via API
Summary When you XML export a command group, the name of configured screen at the group is not included in the XML file. Only name of screens configured at the individual actions are included in the XML file. It is also not possible to set the screen ...
Changed column settings in the dialog for editing a Recipegroup Manager recipe in the editor are not saved in multi-user projects
Summary When changing the column settings in the dialog for editing a Recipegroup Manager recipe in the zenon editor, the changed column settings are not permanently saved in multi-user projects under specific circumstances DescriptionWhen changing ...
When using the Opc2Cli32 Driver in the zenon runtime and using first the Driver command "switch to Simulation mode" (with Opc2Cli32 Driver set to "Hardware" mode in the Editor) and then using the Driver command "switch to Hardware mode" the variables will become invalid and have the Status "switched off" instead of SPONT.
Summary When using the Opc2Cli32 Driver in the zenon runtime and using first the Driver command "switch to Simulation mode" (with Opc2Cli32 Driver set to "Hardware" mode in the Editor) and then using the Driver command "switch to Hardware mode" the ...
When copying a structure datatype containing structure elements in zenon logic then the corresponding structure datatype in zenon does not contain any structure elements.
Summary When in zenon logic creating a structure datatype with structure elements the corresponsing structure datatype in zenon does not contain any structure elements. DescriptionWhen in zenon logic creating a structure datatype with structure ...
In zenon logic the function block "iCOPY" contains a " " (SPACE) in it`s hardware Definition (HWDEF) and as a result causes a wrong sorting in the functionblock library of zenon logic.
Summary The function block "iCOPY" in zenon logic contains a " " (SPACE) in it`s Hardware Definition (HWDEF) and causes a wrong sorting order in the zenon logic function block library. DescriptionThe function block "iCOPY" in zenon logic contains a " ...
When using the function block DTCurDateTime in a Driver Simulation Project, the Output is GMT instead of the local time.
Summary In a Driver Simulation Project, the Output of the function block DTCurDateTime is GMT instead of the local time. DescriptionIn a Driver Simulation Project, the Output of the function block DTCurDateTime is GMT instead of the local time. ...
When using a Driver in mode "Simulation - static" and in the zenon runtime the Driver command "Switch to Hardware mode" is executed, variables of the corresponding Driver get INVALID (correct) but when then executing the Driver command "Switch to Simulation mode" the variable stays INVALID but gets also SPONT.
Summary When performing the Driver command "Switch to Hardware mode" in the zenon runtime variables of a Driver which is running in mode "Simulation - static" get INVALID (correct). When then performing the Driver command "Switch to Simulation mode" ...
Setting a value on a variable of the MATHDR32 Driver which has formula "Mean" is not performed immediately in the zenon runtime. The variable receives the value not before the configured time limit of the Interval Definition of the variable is reached.
Summary When setting a value on a variable of the MATHDR32 Driver which has formula "Mean" configured, the variable receives the value not before the configured time Limit of the Interval Definition is reached. DescriptionWhen setting a value on a ...
When creating a MODRTU32 Driver, in the "Settings" tab of the Driver when selecting "TCP/IP", the TextBox "Connection timeout" is greyed out.
Summary The TextBox "Connection timeout" under the "Settings" tab of the MODRTU32 Driver gets greyed out when selecting "TCP/IP" as Connection. DescriptionThe TextBox "Connection timeout" under the "Settings" tab of the MODRTU32 Driver gets greyed ...
A new Connection under tab "Connections" of the MODBUS_ENERGY Driver can be created with invalid characters like "{}|&~![]()"';="
Summary It is possible to create a new Connection under the "Connections" tab of the MODBUS_ENERGY Driver including invalid characters like "{}|&~![]()"';=". DescriptionIt is possible to create a new Connection under the "Connections" tab of the ...
When importing variables with BECKHNG Driver from a TPY file created with TwinCat 3.1 a few datatypes of variables are not visible and must be modified manually after import.
Summary A few datatypes of variables are not visible when importing variables with BECKHNG driver from a TPY file created with TwinCat 3.1 and must be manually modified after import. DescriptionA few datatypes of variables are not visible when ...
The zenon logic workbench stops working after deletion of a structured datatype in zenon and then closing the error message of zenon logic by clicking on the red "x" sign of the window.
Summary When creating a structured datatype in the zenon editor and then creating a zenon logic Project and opening the zenon logic workbench an error message with text "Failed to create data type "'Copy 0 of xxx'" in zenon Logic! zenon Logic does ...
The WPF element property window may display a different linkage value from the configuration dialog in the Editor.
Summary The WPF element link “Authorization/Interlocking” type may display a different linkage value in the property window from the selected value in the configuration dialog in the Editor. DescriptionThe WPF element link ...
It may happen that some standard recipes screen specific functions are not logged in the chronologic event list in the runtime.
Summary Although the actions are executed correctly, the "new recipe"/"delete recipe"/"read recipe" standard recipes screen specific functions are not logged in the chronologic event list when executed from a client runtime. DescriptionAlthough the ...
The trend screen element may show a false variable overflow in the runtime.
Summary The trend screen element shows a variable overflow despite its value is within the variable value range and the trend element curve option "apply display range from variables" is active in the Editor. DescriptionThe trend screen element shows ...
The screen switch function to a message control screen may not save the "show this dialog in the runtime" option in the Editor.
Summary It may happen that the screen switch function to a message control screen does not save the "show this dialog in the runtime" option in the Editor. DescriptionIt may happen that the screen switch function to a message control screen does not ...
Under specific circumstances the function linked to a reaction matrix state is not executed in the runtime.
Summary The function linked to a reaction matrix state may not be executed if the "call via button in screen alarm message list" option is ticked but greyed out in the Editor. DescriptionThe function linked to a reaction matrix state may not be ...
Time Control properties. Time settings - Execution type: ‘cyclic only on that day’ with the checkbox ‘Interval one month’ or ‘Interval one year’ activated, uses the interval time even though it is greyed out, at the zenon Runtime.
Summary The Time Control Execution type: ‘cyclic only on that day’, when the option ‘Interval one month’ or ‘Interval one year’ is activated: Interval property is greyed out when ‘Interval one month’ or ‘Interval one year’ is selected = OK The issue ...
zenon Runtime closes unexpectedly, when executing the function "trend comparison lot"
Summary Under specific circumstance the zenon Runtime closes unexpectedly, when executing the function " trend compare lot " was executed. DescriptionUnder specific circumstance the zenon Runtime closes unexpectedly, when executing the function " ...
SYSDRV variable ‘Alarm Message List active/inactive’ value is TRUE while AML is deactivated via zenon function.
Summary The System Driver variable ‘Alarm Message List active/inactive’ has value TRUE, also while the AML is deactivated via zenon function ‘Activate/deactivate Alarm Message List, alarm/event groups/classes’ - configured to toggle/deactivate the ...
The min./max. drag indicators of the universal slider may be displaced in the runtime.
Summary The universal slider element minimum/maximum drag indicators may be presented in a wrong position after opening a screen in the runtime. DescriptionThe universal slider element minimum/maximum drag indicators may be presented in a wrong ...
The Web Client freezes when the dialog for requesting the authorization token is moved with the mouse or a click outside the dialog occurs
Summary When network authorization is used in the project and the authorization token is requested on a computer, a dialog appears on the computer that currently possesses the token. If this computer is running a Web Client, clicking the dialog ...
SAIA2ND Driver loads SCommDll.dll instead of SCommDll52.dll
Summary SAIA delivers from PG 5.2 on only SCommDll52.dll. The Driver should use this dlls. DescriptionSAIA delivers from PG 5.2 on only SCommDll52.dll. The Driver should use this dlls. Solution the driver now loads SCommDll52.dll Issue Number: 36051 ...
Under specific circumstances the "current authorization group 1" variable is not set in the runtime.
Summary The "current authorization group 1" system variable may not be set at the first login when a user logs in in the runtime if the login screen is executed as the project start screen. DescriptionThe "current authorization group 1" system ...
Azure Process Gateway - Removing a large quantity of variables from the "Exported into MS Azure" column can take a long time or lead to unexpected behaviour.
Summary In the Azure Process Gateway, removing a large quantity of variables (~1000) from the column "Exported into MS Azure" can take a long time or lead to unexpected behaviour. DescriptionIn the Azure Process Gateway, removing a large quantity of ...
S7TIA Driver: import filter "accessible from HMI" does not work correct with array elements
Summary The array elements have set the "accessible from HMI" flag. When you import variables with zenon S7TIA driver import and set the pre filter "only show variables with this flag!", this variables are not shown. DescriptionThe array elements ...
Under specific circumstances the color palettes displayed in the Editor may come from other project in the same workspace.
Summary When editing an element the color palettes available may belong to other project in the workspace currently loaded in memory. DescriptionWhen editing an element the color palettes available may belong to other project in the workspace ...
The wizard to create a combined element does not set correctly the default state fill color.
Summary Although the wizard to create a combined element with the display type "only screen symbol" sets the default state fill color, this is not used as the "original symbol color" property is active. DescriptionAlthough the wizard to create a ...
The checkbox "non linear value adjustment with macros" should be disabled for Boolean variables in the Editor.
Summary The checkbox "non linear value adjustment with macros" should be disabled and greyed out for Boolean variables in the Editor. DescriptionThe checkbox "non linear value adjustment with macros" should be disabled and greyed out for Boolean ...
Since 7.50, in the Editor, the first Equipment Model node displays the text: "Equipment model data not available"
Summary When there is no Global project in Editor, then the first Equipment model node is displayed as: "Equipment model data not available" (instead "Equipment model"). DescriptionWhen there is no Global project in Editor, then the first Equipment ...
Since 7.50 in Equipment model the tree layout disappears while deleting some node in another window with Equipment model.
Summary The Equipment model may be opened simultaneously in two windows, e.g. from properties dialog and as general window. In that case when you delete a node in the tree opened form properties dialog then all the content in other window disappears. ...
Report viewer rdl automatic template gives error if more than one data set of the same type is used
Summary More than one data type of the same types can be used - but when the user create a new report, the automatic template (generated by zenon) will not work, as more than one item has a the same name. DescriptionMore than one data type of the ...
Combo-Box properties in the dialog view of the properties window in the zenon editor appear selected with a blue background
Summary Several properties for a zenon logic project that are available through a Combo-Box in the dialogview of the properties window in the zenon editor, are displayed selected with a blue background. The properties itself display the correct value ...
'remove selected elements' at an Equipment Model group does not remove elements from properties of RGM recipe groups
Summary In Equipment Model module, when calling 'linked elements' and 'remove selected elements', all elements are removed from lists (e.g. by screens), however equipment model groups linked at RGM groups, are not removed. DescriptionIn Equipment ...
By turning the History of Changes on or off there is strange handling of the message box to close zenon Logic Workbench
Summary When clicking on the checkbox to enable or disable the History of Changes for a project in Editor, you get a message box that changing the state will close the Workbench (if open) of zenon Logic. You can select Yes or No. In both cases, the ...