7.60
zenon Editor – Color Palettes. Importing new palette with extra colors is not added proper.
Summary For the cases when importing a new color palette with more colors than the existing palettes, then the already existing color palette will be amplify with the supplementary colors until the same amount as the new imported color palette. But ...
zenon Editor – Styles. When changing the ‘Fill color’ of the ‘Fill style’, then the property ‘Gradient Color -> Automatic’ will be not updated as expected.
Summary For a static element with fill options for example like for a created rectangle with property ‘Gradient color = Automatic’ selected and changing the value of ‘Fill color’ then the value of ‘Gradient color’ changes at the same time. But, when ...
With the System Text Wizard not all parameters of the ‘User administration windows’ will be updated.
Summary If the function called ‘Change user’ (User administration -> Change user) will be executed at the zenon Runtime it may occur that the parameters ‘TRUE, NONE and FALSE’ will be not updated into the language which was chosen before. These ...
The Outlook profile in message control workspace properties might be empty in the Editor.
Summary When opening for the first time the message control e-mail message (Outlook) properties the profile may be empty. DescriptionWhen opening for the first time the message control e-mail message (Outlook) properties the profile may be empty. ...
It may be possible to move the alarm status line in the frame editor with the "use default position" property enabled.
Summary It should not be allowed to move the alarm status line in the frame editor with the "use default position" property enabled when selecting other frame and using the arrow keys on the keyboard. DescriptionIt should not be allowed to move the ...
multi-select of screen elements on properties with preview opens dialogs for each element
Summary In Editor, when more than one screen element is selected then for properties with preview (e.g. dynamic fill color) the preview opens dialog for each selected element. In addition, if in the property a variable is already linked and the ...
The logging in the diagnosis viewer of the MATHDR32 driver should provide more detailed information in case an issue occurs.
Summary The MATHDR32 driver should provide more detailed logging information in the diagnosis viewer in case an issue occurs. DescriptionThe MATHDR32 driver should provide more detailed logging information in the diagnosis viewer in case an issue ...
The defined keyboard screen for editing Recipegroup Manager recipe variable values, may not open in the runtime under specific circumstances.
Summary When a keyboard screen is linked to a recipe variable at the Recipegroup Manager in the editor, this keyboard screen may not open in the runtime when the new recipe value list is used and a multi-hierarchical project structure is used. With ...
Changing the Recipegroup Manager recipe status texts in the editor does not correctly update the detail view in the editor
Summary When the status texts for the Recipegroup Manager recipe statuses are changed in the editor, the change is taken over and displayed in the properties window however the detail view still shows the previous status text. DescriptionWhen the ...
IEC870_103 driver has on tab 'Com' useless setting 'Protocol'.
Summary IEC870_103 driver on configuration tab 'Com': “Protocol: None” is to be the only acceptable option (defined in Standard) the dialog should not list other Options. DescriptionIEC870_103 driver on configuration tab 'Com': “Protocol: None” is to ...
String commands containing non-standard ASCII characters may not be written correctly to the PLC.
Summary It may be written to a PLC an improper string (i.e. “zenon7XXsp0_build\so”) or empty characters after the last ASCII character used when a string command has non-standard ASCII characters. DescriptionIt may be written to a PLC an improper ...
The Extended Trend screen may present an unexpected behaviour when applying the “No time filter” option via the Time/Lot filter screen in the runtime.
Summary The option “No time filter” of the Time/Lot filter screen leads the Extended Trend screen to present an unexpected behaviour in the runtime as this type of time filter is not supported by the Extended Trend screen. DescriptionThe option “No ...
When starting the runtime twice the second runtime produces an unhandled exception.
Summary When starting the runtime twice the second runtime produces an unhandled exception. DescriptionWhen starting the runtime twice the second runtime produces an unhandled exception. Solution An issue has been resolved so that the second runtime ...
Under specific circumstances the visibility of screen elements does not work correctly in the runtime.
Summary When a combined element contains a project symbol with an element using the visibility property linked to a variable the respective element is always visible in the runtime. DescriptionWhen a combined element contains a project symbol with an ...
SNMPNG32 driver increases memory usage over time.
Summary The memory usage of the SNMPNG32 driver is increasing over time. DescriptionThe memory usage of the SNMPNG32 driver is increasing over time. Solution This issue has been addressed by improving the way variables are read. Issue Number: 36535 ...
Under specific circumstances the customized login screens may not pop-up in the runtime.
Summary The customized login screen for authorization with signature does not pop-up when the write set value is done directly in the element; instead it is presented the standard login screen in the runtime. DescriptionThe customized login screen ...
Under specific circumstances the gif animation does not play in the runtime.
Summary If the switch element graphics file for OFF is not animated or not present, the animated graphics file for ON will not play in the runtime. DescriptionIf the switch element graphics file for OFF is not animated or not present, the animated ...
Under specific circumstances the automatic line coloring switch input/output property is not accessible in the Editor.
Summary The switch input/output property may not be immediately available after selecting the automatic line coloring transformer or switch functions in the Editor DescriptionThe switch input/output property may not be immediately available after ...
When activating or deactivating the zenon logic function block MBSLAVETCP via the zenon logic workbench during runtime, the zenon logic runtime stops working.
Summary The zenon logic runtime stops working when activating or deactivating the zenon logic function block MBSLAVETCP via the zenon logic workbench DescriptionThe zenon logic runtime stops working when activating or deactivating the zenon logic ...
The system text: ‘The system is locked! Contact your administrator!’ cannot be translated be using keyword from system text file.
Summary When using keyword: ‘The system is locked! Contact your administrator!’ it is not possible to translate it via Language Table. This system text appears at a popup window, when a zenon Runtime User try’s frequently too login but the system is ...
Some keyboard combination of Polish diacritic signs didn’t work proper at the Language Table.
Summary It could be that some of Polish diacritic signs (alt + sign) couldn’t be written directly into Language Table via Keyboard. Diacritic signs which are concerned, regardless if upper or lower cases: Ą, Ć, Ę, Ł, Ń, Ó, Ś, Ź and Ż For example: ...
Under specific circumstances the switch element does not respond to the mouse clicking in the runtime.
Summary The switch element may stop reacting in the runtime when the momentary switch option is activated. DescriptionThe switch element may stop reacting in the runtime when the momentary switch option is activated. Solution The issue was resolved. ...
Context menu lock changes may not be transferred to client runtimes.
Summary The Server Runtime may not transfer the information about context menu lock changes in a client to other clients (including the Standby Runtime), so that only informs changes done directly on it. DescriptionThe Server Runtime may not transfer ...
The OPC UA server sends a PublishResponse with DataChangeNotification after a MonitoredItem is removed although no values have changed
Summary After an OPC UA client removes a MonitoredItem from the Subscription, the OPC UA server sends a DataChangeNotification with the current value for all remaining MonitoredItems in the subscription, even though the values or status did not ...
In IEC870_103 driver configuration the names of polling parameters are incorrect
Summary Wrong name of property in the IEC870_103 driver configuration - in ‘Timing and polling’ dialog: - it is written "Channel" it should be "Class". DescriptionWrong name of property in the IEC870_103 driver configuration - in ‘Timing and polling’ ...
While type mismatches zenon Process Gateway ICCP-TASE.2 as server is corrupting value of not mismatched variables after short connection loss.
Summary Issue in zenon Process Gateway as ICCP-server. After short connection loss with remote ICCP-client the zenPG is transferring to the Runtime wrong values of some variables configured on tab 'server'. It does it with wrong values - values of ...
While type mismatches zenon Process Gateway ICCP-TASE.2 as client on data set reception is corrupting value of not mismatched variables
Summary zenon Process Gateway ICCP TASE.2 is mismatching received values - all (or some) of zenon variables linked in ICCP-client. It transfers to the Runtime values of another received data points or random. It happens only when by one (or more) ...
The dynamic text element property "use limit value color" may not work as expected in the Runtime.
Summary The dynamic text element property "use limit value color" from variable may not work in the Runtime when executing a unit switch and the displayed text is set as "variable value". DescriptionThe dynamic text element property "use limit value ...
The WPF element Pareto Diagram may stop working in the Runtime.
Summary The WPF element Pareto Diagram does not update values from the linked variables after executing a screen switch function in the Runtime. DescriptionThe WPF element Pareto Diagram does not update values from the linked variables after ...
The time to open a screen in the Runtime might increase over time.
Summary The time required to open a screen in the Runtime might increase after reloading the project online. DescriptionThe time required to open a screen in the Runtime might increase after reloading the project online. Solution An issue has been ...
It may be shown "unexpected file format" when opening a screen in the Editor.
Summary When opening a screen in the 64 Bit Editor it may be shown "unexpected file format" . DescriptionWhen opening a screen in the 64 Bit Editor it may be shown "unexpected file format" . Solution An issue has been resolved so that screens can be ...
Under specific circumstances the extended trend screen does not display the configured font in the Runtime.
Summary When using global fonts or after removing a font from the font lists it may occur that the font configured in the extended trend screen is not used in the Runtime. DescriptionWhen using global fonts or after removing a font from the font ...
The Runtime may close unexpectedly when clicking on a combined element.
Summary The Runtime may close unexpectedly when clicking on a global symbol that contains a combined element without any variable linked and the visibility of the symbol is taken from a variable. DescriptionThe Runtime may close unexpectedly when ...
Under specific circumstances users can be deleted by any user in the Runtime.
Summary If there is a copy of the MDI button for deleting users in the "user list" screen, any user, including the SYSTEM user, can delete other users through the copy of the button in the Runtime. DescriptionIf there is a copy of the MDI button for ...
The system variable "teaching status" may not be updated in the Runtime.
Summary The system variable "teaching status" is not updated in the Runtime after reloading the project online when this is linked to a reaction matrix. DescriptionThe system variable "teaching status" is not updated in the Runtime after reloading ...
DNP3_TG: The log messages for the data link layer in the diagnosis server contain invalid characters
Summary Data link layer log messages from the DNP3_TG driver with enhanced logging enabled contain invalid characters. This issue affects the log messages only, the communication is not affected. DescriptionData link layer log messages from the ...
In specific circumstances the variable limit property "Additional information 2" cannot be changed in the Editor.
Summary The limit property “Additional information 2” cannot be set in the Editor for structure datatype variables although the properties of the variable are separated from the datatype. DescriptionThe limit property “Additional information 2” ...
The Runtime may not start after configuring the Production & Facility Scheduler module.
Summary The Runtime may not start when configuring time model groups without any shift assigned in the Production & Facility Scheduler. DescriptionThe Runtime may not start when configuring time model groups without any shift assigned in the ...
Aggregate Archive is not applied correctly to local time-zones
Summary Daily aggregate archives are not starting/stopping at 00:00 like they are configured in different time zone. DescriptionDaily aggregate archives are not starting/stopping at 00:00 like they are configured in different time zone. Solution ...
Online data does not show all available data if zoom out is used
Summary Extended Trend does not refresh data avaialble on the online chart after zoom out function DescriptionExtended Trend does not refresh data avaialble on the online chart after zoom out function Solution Whenever a zoom-out is performed, reload ...