Service engine crashes when removing columns in AML or CEL
Description If in the Service Engine in the AML or CEL screen columns are removed from the list while the filter row is active, the Service Engine is closed unexpectedly. This bug has been fixed. Columns can be removed from AML and CEL again as ...
straton Workbench / Logic Studio: Password can not be set/reset anymore on UDFB
Description In Logic Studio, the password can no longer be configured for programs of type "UDBF". It is no longer possible to open the "Security" tab in the "Properties" dialog for these programs. An error message indicates that this name is already ...
Straton Workbench TLS settings are not correct stored
Description When creating a fieldbus configuration in zenon Logic, the settings for TLS are not saved correctly under certain conditions. When the configuration is reopened after saving, the configured settings have disappeared or no longer ...
Zenon Logic: OEM specific blocks and functions are marked as not supported after coverting a project from zenon 12 to zenon 14
Description When converting from zenon 12 to zenon 14, OEM specific functions and blocks for zenon Logic are marked as "not supported". This is due to a name change in the "Select" tab of the "Target System Configuration" dialog. "Logic Runtime for ...
Unicode - Bad handling of accents in folder names
Description In zenon Logic, the character "é" is not displayed correctly in Unicode in folder names. This bug has been fixed. All characters are displayed correctly in Unicode again. To benefit from this fix: Update your zenon Software Platform to ...
Logic Monitoring closes unexpected when opening k5m files
Description When trying to open a k5m file with the Logic Monitoring tool, Logic Monitoring closes unexpectedly. This error has been fixed. k5m files can be opened in Logic Monitoring again as expected. To benefit from this fix: Update your zenon ...
LINT limits badly checked when forced
Description The permitted values for LINT variables are between -9 223 372 036 854 775 808 and 9 223 372 036 854 775 807. If an attempt is made in zenon Logic to force the lower limit value -9223372036854775808 for a LINT variable, the error message ...
Embedded HMI: bitmap paths with accents are not displayed in the editor
Description In the Embedded HMI for zenon Logic, paths for bitmaps are not displayed if they contain accents. This behavior has been changed. Paths with an accent in the name are displayed correctly. To benefit from this fix: Update your zenon ...
LD: confusion between FB input and global variable
Summary In zenon Logic, the global variable is used instead of the local parameter in certain constellations in the Ladder Diagram (LD). This has been fixed. Description In zenon Logic, a user-defined function block has an input parameter. This has ...
The columns in the Listcontrol of Alarm Message List and Chronological Event List cannot be arranged if the runtime files are created for 7.20
Summary The column headers of configurable lists in the Alarm Message List and the Chronological Event List cannot be configured in the Service Engine under certain conditions. This bug has been fixed. Description In AML and CEL, the columns of ...
History of changes/Smart objects: A change in a property of the SOT (e.g. variable name) causes a change in all properties in the corresponding instances.
Description Changing a property of a Smart Object Template (SOT) causes an entry to be made in the “History of Changes“ for all properties in the corresponding instances. This leads to a rapidly growing database with a lot of superfluous information. ...
Deleting of an Referenced Smart Object Template causes Zenon to Crash
Summary Deleting a referenced Smart Object Template (SOT) causes zenon to exit unexpectedly. This error has been fixed. Description A SOT contains a zenon Logic project and a variable that is externally visible for zenon Logic. This SOT is referenced ...
Copying an SOT containing a frame results in project corruption
Description If a Smart Object Template (SOT), which contains a frame, is copied, the zenon project will be corrupted. The next time the Engineering Studio is opened, the SOT cannot be loaded and the project cannot be activated. An error message ...
Compiler crashes when parsing a LD program
Description zenon Logic is terminated unexpectedly when building an LD program. The cause is the handover of a two-dimensional array to a UDFB that expects a one-dimensional array as input. This cannot work and leads to an error. It is expected that ...
Defect V14 - straton editor does not display accents correctly when the editor is in French
Description zenon Logic Studio does not always display accents correctly in French. This has been fixed. Accents are used correctly again. To benefit from this fix: Update your zenon Software Platform to the latest build of zenon 14 or higher. Item ...
[3D Integration] Triggering limit values don't always led to correspondent highlighting on 3D models present in multiple zenon screens
Description In 3D Integration, the violation of limit values is not always indicated in the corresponding 3D models if they are used in several zenon screens. This bug has been fixed. Limit value violations are displayed in all linked models. To ...
WVS: Combined element with formula that considerates X01.not acknowleged cause crash
Description If a combined element containing a formula with "not acknowledged" is opened in a screen in the Web Visualization Service (WVS), this leads to an unexpected termination of the WVS. This bug has been fixed. To benefit from this fix: Update ...
Buttons configured as pushbuttons never reset after holding time, keeping the on-value set.
Summary In the Service Engine pushbuttons are not reset after the holding time. This has been fixed Description In the Service Engine, buttons that are configured as pushbuttons are not reset after the holding time. They retain the switch-on value. ...
[3D Integration] Limit-violations are not reflected in the 3D Model
Summary In 3D Integration, limit violations in the 3D model are not taken into account. This has been fixed. Description Limit violations are not displayed in the 3D model if they occurred before the screen with the affected model was opened. The ...
File Inspector: It cannot open specific ARX files (healthy)
Description In version zenon 14, the File Inspector generates a parsing error when trying to open properly saved ARX files. This bug has been fixed. ARX files are opened successfully again. To benefit from this fix: Update your zenon Software ...
IEC870 driver: does not call function "OnReceiveFrame()" in the IEC870OEM.DLL since a certain Build update
Description The IEC870 driver no longer calls the "OnReceiveFrame()" function from the optional IEC870OEM.dll. This bug has been fixed. The call is executed as expected again. To benefit from this fix: Update your zenon Software Platform to the ...
Active directory: Password never expires wrong interpreted when eSignature is used
Summary Active Directory configured with a password that never expires prevents the use of eSignature. This bug has been fixed. Description If a password is set to never expire in Active Directory in the group password policies or in the user account ...
[MSI Interface] Parameter values from order parameter messages are not written to variables
Description In the MSI Interface, parameter values from "order parameter messages" are not written to variables as expected. The LOG file refers to: "System.Collections.Generic.KeyNotFoundException: The specified key was not present in the ...
OPCUA Process gateway is crashing after reloading
Description If the Service Engine is reloaded when alarms are pending, the Process Gateway is sometimes terminated unexpectedly. This bug has been fixed. To benefit from this fix: Update your zenon Software Platform to the latest build of zenon 14 or ...
[SAP Interface] Values of export parameters of SAP function are not assigned to variables
Summary Two bugs occur in the SAP Interface: In the Service Engine, zenon variables are not updated correctly. And in the Engineering Studio, import/export parameters are swapped when importing RFC function configurations. These two bugs occur ...
Acknowledgement of alarms limited to equipment groups does not work if the user data comes from an external identity provider (AD, Identity Service)
Summary The acknowledgement of alarms that are restricted to system groups does not work if the user data originates from an external identity provider such as Active Directory or Identity Service. This error has been fixed. Description In AML, the ...
Historian RDA: Some samples are misdirected into +/-1h files (data source: SQLDRV)
Description When using the RDA functionality in the Historian, entries are incorrectly saved in files +/- 1 hour to the expected file. The cause lies in the handling of daylight saving time and standard time. When determining whether a time is ...
Setpoint input for Keyboard screen doesn’t work in Batch Control
Description In Batch Control, the setpoint input in a screen of type keyboard does not work as expected. When entering a value via a button that is linked to the function "Setpoint input for keyboard screen", the input is not executed correctly. The ...
S7TCP driver and others : No red square on variables if the hardware communication is not established.
Description If the S7TCP driver cannot establish communication with the hardware, the red square that is supposed to indicate this is not displayed in the Service Engine. The status display is also empty. This occurs in zenon 12 with build versions ...
History of changes: Released symbol properties creating a lot of history of changes events
Description In History of changes, released symbols generate a very high number of unneeded entries when Service Engine files are created. With many symbols and many screens, this can lead to impairments. This behavior has been modified. In the ...
BuRPVI: Sporadically some datapoints do not receive status (SPONT) or receive INVALID when starting service Engine
Description Sporadically some variables from the BuR-PVI driver with the driver object type "PLC marker" do not receive a status (SPONT or INVALID) when the Service Engine is started. No PVI events are sent initially for these datapoints. This error ...
Control Recipe import with (and without) unit placeholder doesn’t work
Summary In Batch Control, the import of a control recipe that was previously validated without errors fails. This error has been fixed. Description In Batch Control, a control recipe with or without a unit placeholder is validated and exported ...
zenon logic: 1 gain FB with LD can't assign a structure to a structure
Description In zenon Logic it was not possible to add a structure to a structure in LD. However, this is possible in ST and FDB. As a workaround, you can activate the "LD optimizations" option in the project settings in LD. This behavior has been ...
HTML screen: Opening PDF files with extra arguments does not works
Description If additional parameters are specified when opening PDF files via a screen of type HTML, the PDF is not opened when using WebView2. Instead, a "File not found" error is displayed. The use of additional parameters and outputs via WebView2 ...
Double Cursor present wrong value "1" even the 1st/2nd cursor's var value is "0" when time difference is "0"
Description In Extended Trend, the double cursor shows the wrong average value “-nan(ind)” when using numeric variables, even if the value of the 1st and 2nd cursor is “any”. The problem occurres when the double cursor’s time difference second is set ...
Project in zenon Logic takes long time to Build external POUS when added manually
Description zenon Logic projects take a long time to load external POUs manually. This behavior has been modified. The loading times of POUs have been significantly reduced. To benefit from this fix: Update your zenon Software Platform to the latest ...
Cached credentials don't work when a domain set in project settings
Summary Cached credentials for Active Directory login do not work with zenon Service Engine if a domain has been set in the project settings. This has been fixed. Description The project properties "Active Directory domain" and "User group for Active ...
Structured Datatype don't update in zenonLogic after being edited
Description In zenon Logic, structured data types are not updated after editing a property of a structure element in zenon. This occurs in particular with distributed engineering. As a workaround, the "Logic to SCADA connection" can be deleted in the ...
File inspector cannot open .CEL files
Description When trying to open a file of *.CEL format in File Inspector, the error message "Directory not found" is displayed. The issue has been addressed and the behavior is now as expected. To benefit from this fix: Update your zenon Software ...