7.10
The Weihenstephan client driver in the zenon logic stops working if for a LIST in the Weihenstephan client driver more than 256 tags are configured
Summary When in a LIST in the fieldbus configuration for the Weihenstephan client driver more than 256 tags are configured, the Weihenstephan client driver stops working in the zenon logic runtime. Description When in a LIST in the fieldbus ...
IEC61850 Server uses TPDU size 255 in the COTP connection confirmation message when connecting client does not provide TPDU size
Summary The IEC61850 Server I/0 driver in zenon Logic: when a client initiates connection and proposes a TPDU size the Server uses this provided TPDU size. But when the client does not provide the size, the Server responds in COTP connection ...
zenon Everywhere Server respectively the zenon Runtime is closing under specific circumstance with an unhandled exception.
Summary It could be possible, that the zenon Runtime is closing with an unhandled exception. Under specific circumstance e.g. when a zenon client isn't connected to its configured server and a zenon everywhere client is connected and request for ...
The holidays in the calendar of the Scheduler/Production and Facility Scheduler are not from the previously configured country.
Summary After reopening the Scheduler/Production and Facility Scheduler properties in the editor, the previously designated country to define the holidays is incorrectly selected and loaded in the calendar. Description After reopening the ...
The zenon Analyzer Wizard cannot export Production and Facility Scheduler data.
Summary The zenon Analyzer Wizard cannot export the necessary Production and Facility Scheduler information to the Analyzer database from zenon 7.11 editor because the Application Programming Interface method PFSGroup.SystemModelGroupAtIndex(0) ...
Under specific circumstances the zenon Logic runtime stops unexpectedly.
Summary The zenon Logic FTP function block causes the zenon Logic runtime to suddenly close when the ENABLE input is set to TRUE. Description The zenon Logic FTP function block causes the zenon Logic runtime to suddenly close when the ENABLE input is ...
Sometimes archive entries are lost when changing archive values via the API
Summary When changing archive values in a current open capsule/file via the API sometimes archive entries are lost/deleted entirely. Description When changing archive values in a current open capsule/file via the API sometimes archive entries are ...
When writing archives fails via API a messagebox is shown instead of return value.
Summary Messagebox regarding archive writing failure should be suppressed when the saving via the API fails. Instead a return value should be returned by the called function. Description Messagebox regarding archive writing failure should be ...
Block-Array variables are not shown in Extended Trend on Windows CE plattform
Summary Block-Array variables are not displayed in an Extended Trend with a Windows CE 6.0 Panel. Extended Trend with online variables there is no effect. On the PC there are no effects with Block-Array and online variables. Testet with Windows CE ...
It may occur that the Active Directory login takes a long time to be executed in the runtime.
Summary Under not specified circumstances the active directory user data takes a long time to be read slowing down the active directory login in the runtime. Description Under not specified circumstances the active directory user data takes a long ...
It may occur that when exporting/importing a screen via XML the position of the symbols is lost in the editor.
Summary The XML export/import of screens containing symbols in single edit mode does not copy their position causing the new screen to display the symbols in an incorrect position. Description The XML export/import of screens containing symbols in ...
Under specific circumstances the runtime warns twice the user that it does not own the required authorization level to execute a function.
Summary If a user that does not own the required authorization level clicks in the runtime a combined element linked to a variable and a function, it is shown twice the warning message box "You are not entitled to execute this function" . ...
When time synchronization command -T103 - is disabled by flag and IEC60870 Slave does not execute it but responds activation positive (missing P/N bit)
Summary The IEC60870 Slave (Process Gateway/zenon Logic) has a flag to enable/disable time synchronization commands - T103 variable. When this variable value is 0 (disabled) and a client sends activation of command T103, the Slave ignores the ...
IEC870 driver (Master): online import creates T00 variables with wrong name and COA value
Summary By online import from PLC the IEC60870 Master driver (zenon / zenon Logic) proposes to create also variables for 'connection status' - two variables of Type ID = 0 and with IOA=0 ("connection status") and IOA=1 ("status of Data Link ...
Events from COM interface are not available in Windows CE
Summary When using ActiveX controls, events provided by the COM interface are not available. Event handlers which are registered on these events in ActiveX controls are not triggered because the events are not fired properly. Description When using ...
It may occur that the border's thickness of the screen elements change after a rotation in the editor.
Summary For specific rotation angles the border's thickness of the screen elements change in the editor. Description For specific rotation angles the border's thickness of the screen elements change in the editor. Solution The scaling factor of the ...
The OPCUA process gateway may close unexpectedly under specific circumstances when reloading the runtime
Summary With an OPCUA process gateway with a larger number of variables cofigured and an OPCUA client connected to the OPCUA server having one or more subscriptions, the OPCUA server may close unexpectedly under specific timing conditions if the ...
An absolute path as a value in a string variable for the Recipegroup Manager export file name is not considered correctly
Summary When using an absolute path to a file name in a string variable value as a parameter for the Recipegroup Manager export function, the recipe or group is not exported correctly. A file "D:_export_exportGrp1.xml" is created in the export ...
Writing a variable of the OPCUA client driver in the zenon logic via externally visible does not set the value correctly
Summary With an OPCUA client driver in zenon and a variable that is set to "externally visible" writing this variable in a zenon logic program does not correctly send this value to the OPCUA server. Instead of the correct value, the value "0" may be ...
Under specific circumstances the editor does not display the original size of the graphics as configured.
Summary When a symbol containing a graphic set to be displayed with the original size is added to a screen, the graphic in the editor is scaled to the size of the symbol, but in the runtime it has the original size showing an inconsistent behaviour. ...
When the command screen does not contain the control 'lock comment', lock is impossible
Summary When you create a command screen without the control 'lock comment', then in the Runtime a valid user with a valid lock code can't lock the data point. The action 'lock' fails without any message why not locking. The workaround: place field ...
Under specific circumstances the editor suddenly closes when configuring the start screen of the project.
Summary The editor closes unexpectedly when a Keyboard screen type is created in the start screen property and it is selected as the start screen of the project. Description The editor closes unexpectedly when a Keyboard screen type is created in the ...
The editor/runtime does not start if the license serial and activation numbers are not defined.
Summary If the zenon6.ini contains an empty SERIAL7= and ACTIVATIONKEY7= entries, the editor/runtime does not start and the CPU load is at 100%. Description If the zenon6.ini contains an empty SERIAL7= and ACTIVATIONKEY7= entries, the editor/runtime ...
The automatic line coloring markers are not correctly saved when creating a project backup in the editor.
Summary Each time creating a project backup in the editor the amount of configured automatic line coloring markers is doubled in the project.ini causing the backup load in the editor and the start of the server/standby/webclient runtime to take ...
The zenon Logic runtime does not start on a specific touch panel computer.
Summary The zenon Logic runtime does not start in the TPC-31T panel running on a Windows CE 6.0 operating system. Description The zenon Logic runtime does not start in the TPC-31T panel running on a Windows CE 6.0 operating system. Solution An issue ...
If no encryption is used for POP3 server in Message Control, the runtime stops responding
Summary When no encryption is used in the configuration of SMTP mail for the POP3 server, the runtime stops responding when mails are polled the first time. Description When no encryption is used in the configuration of SMTP mail for the POP3 server, ...
Dynamic content for Message Control welcome message when using Text To Speech
Summary The Welcome message for Text To Speech is played when the operator picks up the phone. This message has been static and could not be modified or altered in any way. Description The Welcome message for Text To Speech is played when the ...
Message Control doesn't recognize messages which are sent successfully over SMS gateway
Summary If Acknowledgement required is not used for a message sent over SMS gateway, Message Control does not recognize successfully sent messages. Description If Acknowledgement required is not used for a message sent over SMS gateway, Message ...
PfsModellBreaks.CreateBreak() demands wrong argument under VSTA
Summary In VBA, the method PfsModellBreaks.CreateBreak() demands argument type string, in VSTA it demands a string array. However, if a string array is used, an exception occurs. Description In VBA, the method PfsModellBreaks.CreateBreak() demands ...
RGMRecipeGroup.AddVariable() does not accept a variable from a sub project.
Summary RGMRecipeGroup.AddVariable() does not accept a variable from a sub project. Description RGMRecipeGroup.AddVariable() does not accept a variable from a sub project. Solution The object model was extended so RGMRecipeGroup.AddVariable() now ...
Suppressing equipment model in Message Control and pressing "refresh" or reopening the Message Queue screen results in multiple entries in the suppressed equipment list
Summary Suppressing equipment model in Message Control and pressing "refresh" or reopening the Message Queue screen results in multiple entries in the suppressed equipment list. Description Suppressing equipment model in Message Control and pressing ...
Fragmented messages from SMTP server with no AUTH in the answer cause the runtime to stop responding
Summary If SMTP is used and the SMTP server uses fragmented messages to get the answer to the EHLO or HELO request, Message Control is waiting for fragments which results in an unresponsive runtime if no fragments are left to receive. Description If ...
API function Project.ParentProject(string) does not set a project as the child project properly
Summary If Project.ParentProject(string) is called, the project is not set as a child project of the project which was defined in the argument. Description If Project.ParentProject(string) is called, the project is not set as a child project of the ...
SMTP dispatcher closes connection before receiving answer to the EHLO command
Summary If a server needs longer than 100ms to answer on EHLO or is sending a single line response, Message Control is no longer waiting for supported extensions of the SMTP server and supposes that the SMTP server is not supporting SMTP AUTH. ...
In rare cases, acknowledged or timed-out messages from Message Control cause the runtime to stop working
Summary In some cases, an acknowledged message or a message which timed out cause the runtime to stop working. Description In some cases, an acknowledged message or a message which timed out cause the runtime to stop working. Solution An issue was ...
Send Message function does not send messages when triggered by limit without alarm class/group/area
Summary If a Send Message function is triggered by a limit violation which has no alarm group/class/area linked to it, the Send Message function is suppressed if another alarm group/class/area is suppressed. Description If a Send Message function is ...
Runtime ActiveX zenRuntimeCtrl.ocx control does not support hiding it
Summary The zenRuntimeCtrl.ocx does not support hiding and showing it. If the host is trying to hide it and show it a second time, the control is not shown in the host application anymore and stays invisible until the host application is restarted. ...
In some circumstances, Message Control is not showing a voice modem for selection
Summary In some circumstances, Message Control is not showing a voice modem for selection, even if the modem seems to support LINEMEDIAMODE_AUTOMATEDVOICE. Description In some circumstances, Message Control is not showing a voice modem for selection, ...
linking of non-keyboard screens to the keyboard properties in Batch control is possible
Summary The Batch Control module offers several properties where the user can link keyboard screens for improved usability on touch screens. By directly typing the name of a desired screen in the control element, it is possible to link screens of any ...
OnWorkspaceStartup and OnWorkspaceExit event are registered instead of unregistered in the MyWorkspace_Shutdown
Summary OnWorkspaceStartup and OnWorkspaceExit event are registered instead of unregistered in the MyWorkspace_Shutdown. Description OnWorkspaceStartup and OnWorkspaceExit event are registered instead of unregistered in the MyWorkspace_Shutdown. ...