7.10
The OPCUA server in the process gateway stops updating variable values from the runtime under specific circumstances
Summary When the runtime is reloaded following changes to the driver configuration, while the OPCUA server in the process gateway is running and a OPCUA client is connected, subcribing to value changes (Data Access) for variables (nodes) in the OPCUA ...
Copy & Paste of a variable of the OPCUA client driver does not take over the browse name in the copy
Summary After Copy & paste of a variable of the OPCUA client driver, the browse name property of the copied variable is empty and communication in the runtime does not work. Description After Copy & paste of a variable of the OPCUA client driver, the ...
It is not possible to pre-define a time filter for the Industrial Performance analyzer (IPA) in the editor
Summary In the project properties for the IP it is possible to pre-define time filters. There exists however, an issue where under special circumstances the dialog for defining the time filter would not open. Description In the project properties for ...
assigning a database connection to the Industrial Performance Analyzer (IPA) is not possible
Summary The Industrial Performance Analyzer (IP) requires linking a database in which the alarm information will be stored. The connection string to this database has to be stored in a property. To import a connection string, it is possible to select ...
It may occur that the curve list columns of the extended trend screen cannot be changed in the webclient runtime.
Summary The name and title columns of the curve list in the extended trend screen cannot be changed in the webclient runtime. Description The name and title columns of the curve list in the extended trend screen cannot be changed in the webclient ...
Some DynProperties of the Combo-/Listbox element are missing when exporting a screen in the editor.
Summary The DynProperties for the entries created dynamically of the Combo-/Listbox element are not included when exporting a screen to XML from the editor. Description The DynProperties for the entries created dynamically of the Combo-/Listbox ...
Under specific circumstances the change of parameters in functions it is not logged in the editor.
Summary The history of changes log in the editor does not record the change of a parameter of the close frame function created from changing the function type of a previously defined screen switch function. Description The history of changes log in ...
The history of changes adds an incorrect line when a new language file is created the editor.
Summary The history of changes logs an extra line recording that a previous existing language file has been changed when a new language file is created in the editor. Description The history of changes logs an extra line recording that a previous ...
Under specific circumstances the palette colors are not used in the runtime.
Summary The highlight frame surrounding color configured from a palette in the editor is not used when runtime starts and after executing the switch palette function. Description The highlight frame surrounding color configured from a palette in the ...
3S_V3 Driver toggle a bool variable takes 10 seconds to transmit to the PLC and back
Summary When writing a value to a bool variable with the set value function it takes 10 seconds to write and read back the value. Set a value via element works fast. Description When writing a value to a bool variable with the set value function it ...
The runtime may close unexpectedly when the automatic line coloring is used.
Summary The automatic line coloring algorithm may cause the runtime to close sporadically. Description The automatic line coloring algorithm may cause the runtime to close sporadically. Solution An issue has been addressed so that the runtime no ...
The detailed view of the variable list may display an incorrect sorting in the editor.
Summary When the variable list is grouped by drivers, every time it is reduced and expanded a driver node, while the rest of the nodes are collapsed, the variable list is sorted descending, although the column is set to ascending sort. Description ...
The CEL filer is blocked when "Search for" text has several space characters in a row
Summary The search for filter text which contains two or more space characters in a row like "a b" or just " " blocks the Runtime (RT does not react on user operations). Description The search for filter text which contains two or more space ...
LM (former EMS): misleading information when user manually enters wrong min/max switching times.
Summary Issue in Load Management when then user edits the switch-on/off time and makes min value bigger max value: no warning message during compilation of project. In the Runtime wrong configured component is treated like switchable and comes along ...
Not possible to switch language for column headers of MDI element "List display: switching operations preview" in Load Management screen
Summary In Load Management (former EMS) screen there is MDI element "List display: switching operations preview" (ID 53650). This element does not change column headings by language switch in the Runtime. Description In Load Management (former EMS) ...
"System ID" was incorrectly used for "System Number" in the SAP interface
Summary In the SAP interface there exists a property called "System ID" which actually refers to the SAP "System Number". Description In the SAP interface there exists a property called "System ID" which actually refers to the SAP "System Number". ...
Omron Hostlink driver (OMRON32) the driver doesn't convert BCD values for UDINT variables when the value is bigger then 9999
Summary The variable is configured with the driver object type DM-Area BCD and the data type is UDINT. The value is right until 9999 but then the automaticaly convertion doesn't work and for example the value 10000 is then visualized as 65536. ...
The webclient is misplaced in the Firefox.
Summary The webclient is displaced in Firefox so that it is shown a white strip at the top and it is cut-off at the bottom. Description The webclient is displaced in Firefox so that it is shown a white strip at the top and it is cut-off at the ...
Opening existing files in the System Information Collector (SIC) is not possible
Summary Opening files which have been created with an older version of the System Information Collector were can not be opened in the current version any more. Either no information is displayed, or a message box pops up with the information that ...
It may occur that a function linked to a combined element does not work in the runtime.
Summary When clicking a combined element with a function associated in the runtime the function is not executed. Description When clicking a combined element with a function associated in the runtime the function is not executed. Solution An issue ...
It may occur that the faceplate project filter is not applied in the runtime.
Summary The faceplate project filter defined in the editor is lost in the runtime when executing a screen switch function to a faceplate screen located in a higher level project. Description The faceplate project filter defined in the editor is lost ...
Under specific circumstances the bar display element shows incorrect values in the runtime.
Summary The scale of the bar display element is incorrectly set and displayed in the runtime when the display range is set dynamically and the linked variable has defined a linear value adjustment. Description The scale of the bar display element is ...
In integration project when opening an AML screen from a subproject the filter acts on wrong default project
Summary In an integration project when opening an AML screen (or faceplate) from a subproject the filter behaves incorrectly: it can display alarms from another subprojects or not display alarms when it should. Description In an integration project ...
From time to time, at 000ms, zenon Process Gateway sends values with incorrect timestamp.
Summary From time to time and only when variable timestamp has 000ms, the zenon Process Gateway (e.g. IEC870 Slave) sends incorrect timestamps with 1 second back in time. Description From time to time and only when variable timestamp has 000ms, the ...
iec850 driver configuration: list of objects for dynamic data set is empty when driver is configured to use symbolic address and variables are renamed to not use ObjectReference.
Summary The IEC61850 (Client) driver: in the driver configuration the list of objects for dynamic data set is empty when driver is configured to use symbolic address and variables are already renamed. Description The IEC61850 (Client) driver: in the ...
It is not possible to use the zenon logic I/O driver Ethernet/IP Adapter in combination with the Logic to SCADA connection driver.
Summary It is not possible to use the zenon logic driver Ethernet/IP Adapter in combination with the Logic to SCADA connection driver. When starting the runtime following message appears: "Opening bus driver"T5EIPS" for cold resp. warm start ...
Memory usage for KUKA32 driver increases when reading variables which does not exist in PLC
Summary When you define zenon variables which does not exist in the PLC program and use them in screen the driver allocates more and more memory in the runtime. This memory is never released. Description When you define zenon variables which does not ...
Profinet Device Malformed Packet on ReadModuleDiffBlock
Summary In Logic fieldbus driver profinetIO Device on a request from controler 'ReadModuleDiffBlock' the Profinet Device return a malformed message (Invalid size). Description In Logic fieldbus driver profinetIO Device on a request from controler ...
ETM: Export displayed trend data doesn't work correctly with following archive
Summary If you use the "export displayed trend data" function in the runtime with a normal archive, all informations are exported correctly in the .txt file. If you export a following archive the identification and the unit are missing in the .txt ...
MELSECA driver: String variables show the value of the 1st (offset) string variable if displayed on the same screen
Summary MELSECA driver: If string variables with consecutive addressing (offsets) are displayed on the same screen they all show the value of the 1st addressed (offset variable). On different screens the variables display the correct and respective ...
Allen DF1 driver seem to have a delay when reading variables
Summary The driver has a delay when reading Variables. It seem it does wait before sending the response telegram. Description The driver has a delay when reading Variables. It seem it does wait before sending the response telegram. Solution Fix ...
Problems during the import of an XML file in zenon logic if ther is a parameter without value
Summary there is a problem with the XmlParseDocFile Function Block. When there is a parameter without value (parameter="") then the FB returns that there is a "Invalid XML file or XML syntax error" Description there is a problem with the ...
It may occur that a scheduler defined time cannot be activated/deactivated in the runtime.
Summary In Windows CE the scheduler checkboxes in the times dialog to activate/deactivate a defined time are not shown in the runtime. Description In Windows CE the scheduler checkboxes in the times dialog to activate/deactivate a defined time are ...
Under specific circumstances the multi-touch pan gesture is not recognized in the webclient.
Summary The pan gesture is not recognized in the webclient runtime when the multi-touch recognition mode is set to Windows 7. Description The pan gesture is not recognized in the webclient runtime when the multi-touch recognition mode is set to ...
Under specific circumstances the editor suddenly closes when compiling a project.
Summary The combo-/listbox element can cause the editor to close unexpectedly when compiling the runtime files. Description The combo-/listbox element can cause the editor to close unexpectedly when compiling the runtime files. Solution An issue has ...
Under specific circumstances a new time cannot be created in the Production & Facility Scheduler in the editor and runtime.
Summary When creating a new time in the Production & Facility Scheduler in the editor or runtime, the new absolute time point cannot be created if the same set time was used before when configuring a relative point of time. Description When creating ...
A variable in the element Combo/Listbox for create entries dynamicall wasn't replaced at the screen switch function. Also the visibility variable without a dynamically entry couldn't be replaced correctly.
Summary If you use a Combo/Listbox using dynamically entries with variable, that variable wasn't replaced correctly by substitution and also not if you use "replace indices". The visibility variable of the individual state also without using of ...
It may occur at the zenon function "Alarms: acknowledge flashing" with the selected option "All alarms in frame" that no parameter will be shown at the properties.
Summary If a new zenon project was created and a function called "Alarms: acknowledge flashing" was established. Choose "All alarms in frame" and select one of the proposed Frame selections. After saving the parameters the function list shows "???" ...
Under specific circumstances the 64 Bit runtime produces an unhandled exception after opening a chronologic event list screen.
Summary The chronologic event list screen element may cause the 64 Bit runtime to sundenly close in a Windows Server 2012 R2 operating system. Description The chronologic event list screen element may cause the 64 Bit runtime to sundenly close in a ...
On closing the runtime on the server, the runtime on the standby server closes unexpectedly with an unhandled exception under specific circumstances
Summary Under specific circumstances and timing conditions closing the runtime on the server may result in an unhandled exception on the standby server and unexpected closing of the runtime on the standby server. Description Under specific ...
Next page