10
Editor Crashes by using cross referenz list with Symbols
Summary Sometimes deleting a symbol causes subsequent crashes when refreshing cross-refrence list or editing screens Description Sometimes deleting a symbol causes subsequent crashes when refreshing cross-refrence list or editing screens Issue ...
It should be possible to specify bounds for the cycle time
Summary Issue Number: 241961 Fixed on Date: 30.6.2021 Versions: 8.20 0 BUILD 85568 | 10 0 BUILD 85877 | zenon Analyzer 3.40 0 BUILD 87645
EUROMAP63: improve behavior for empty files
Summary EUROMAP63 - high CPU load with many connections Description EUROMAP63 - high CPU load with many connections Issue Number: 240933 Fixed on Date: 24.6.2021 Versions: 8.20 0 BUILD 85568 | 10 0 BUILD 85877 | zenon Analyzer 3.40 0 BUILD 87645 | ...
IEC870 Master Redundancy according to Ed. 2.0 - send only TestFR Act/Con between Master and Slave
Summary Master doesn't recognize connection loss, if both redundant connections fail simultaneously. Thus no general interrogation is requested and further no spontaneous value changes are transmitted. Description Master doesn't recognize connection ...
IEC60870-5-104 drivers (master and slave) are loosing redundant connection because of errors in START/STOP procedure implementations
Summary When triggering a manual redundancy switch the IEC60870-5-104 master acknowledges outstanding dl-frames after sending STOPDT. This may cause the slave to ignore the ack or even close the master connection. Description When triggering a manual ...
GDI Leak: Batch Control Recipe Editor
Summary Each time Batch Control Recipe Editor is opened 6 GDI objects are leaked Description Each time Batch Control Recipe Editor is opened 6 GDI objects are leaked Issue Number: 242796 Fixed on Date: 15.7.2021 Versions: 8.20 0 BUILD 86192 | 8.00 0 ...
SPRECON870 driver is crashing if more than 22 IOA are communicated in a Reverse Direction Telegram
Summary - Description - Issue Number: 242750 Fixed on Date: 15.7.2021 Versions: 8.20 0 BUILD 86192 | 8.00 0 BUILD 86400 | zenon Analyzer 3.40 0 BUILD 87645 | 8.10 0 BUILD 86641 | 10 0 BUILD 87728 | 7.60 0 BUILD 95308 | 8.10 0 BUILD 95414 | 8.00 0 ...
GDI Leak: Modal dialog & Highlight frame settings leads to a GDI leak after closing the frame
Summary Opening a modal dialog with highlighting screen causes a GDI leak Description Opening a modal dialog with highlighting screen causes a GDI leak Issue Number: 243041 Fixed on Date: 23.7.2021 Versions: 8.00 0 BUILD 86400 | 8.20 0 BUILD 87225 | ...
S7TIA: Variables cannot be imported from TIA project when CPU name contains dots (.)
Summary All Version do not resolve dots (.) as part of CPU-name properly. This leads to problem with importing variables from TIA-projects or pre-compiled projects. With the current bugfix CPU-names containing dots are quoted to recognise it and to ...
RGM: Runtime may crash when variables in a recipe are linked to a visibility variable
Summary Runtime crashes if RGM visbility changes while a set-value keyboard is open Description Runtime crashes if RGM visbility changes while a set-value keyboard is open Issue Number: 242794 Fixed on Date: 21.7.2021 Versions: 8.00 0 BUILD 86400 | ...
S7TIA: improved communication performance
Summary Issue Number: 214306 Fixed on Date: 7.7.2021 Versions: 8.00 0 BUILD 86400 | 10 0 BUILD 85877 | zenon Analyzer 3.40 0 BUILD 87645 | 8.10 0 BUILD 86641 | 7.60 0 BUILD 88730
Systemtext wizard doesn't create 43 systemtexts in different languages
Summary The separator for strings used was "space %d space" this was making wrong string splits. It was fixed by using "%d" as string separators. Description The separator for strings used was "space %d space" this was making wrong string splits. It ...
User duplication is not verified in Customised Edit user screen.
Summary Fixed, i.e. in MDI user screen a user cannot be added twice any more. Description Fixed, i.e. in MDI user screen a user cannot be added twice any more. Information Using PWD_Validate password API function, we have checked list of users and ...
EthernetIP Scanner overloads logic runtime when no connections are established
Summary Ethernet IP Scanner with lost Connection leads to a cycle time increase until the Connection is reastablished. Description Ethernet IP Scanner with lost Connection leads to a cycle time increase until the Connection is reastablished. ...
Crash happens when deleting more than one graphic file in a SOT
Summary Now user is able to delete multiple files from graphics, help, mutlimedia.. etc. of File Manager. Crash is resolved now. Description Now user is able to delete multiple files from graphics, help, mutlimedia.. etc. of File Manager. Crash is ...
Merge Abstraction Layer to zenon 10
Summary Issue Number: 241022 Fixed on Date: 0.0.0 Versions: 10 0 BUILD 85877
T5Bus870Slave - Incorrect response if information in Select and Execute is different
Summary - Description - Issue Number: 214031 Fixed on Date: 0.0.0 Versions: 10 0 BUILD 85877
Wrong SOT version number displayed after update
Summary SOT version number will be persisted after the SOT update, and after closing and reopening the engineering studio it should still be the same as after the update Description SOT version number will be persisted after the SOT update, and after ...
snmp32 driver does not work in version 10
Summary SNMP32 driver does not work in version 10. Description SNMP32 driver does not work in version 10. Information no workaround Issue Number: 242073 Fixed on Date: 0.0.0 Versions: 10 0 BUILD 85877
Sigmatek Lasal Driver cannot read data in zenon 10
Summary Sigmatek Lasal Driver not working in version 10. Description Sigmatek Lasal Driver not working in version 10. Information / Issue Number: 241474 Fixed on Date: 0.0.0 Versions: 10 0 BUILD 85877
Smart Object Update causes unhandeld exception when exiting the Engineering Studio
Summary Crash is not happening anymore when closing the engineering studio after updating a SOT Description Crash is not happening anymore when closing the engineering studio after updating a SOT Information No Workaround found. Issue Number: 241750 ...
AML: Comment for Alarm disappears in Data Storage
Summary The reason for the disappearing comments (and also alarm causes) was that the ringbuffer was not correctly synchronized with historic data when binary files were disabled. Also acknowleding and confirming acknowledge was not correctly ...
Sporadic crash in Service Engine when Identity Service user administration is combined with alarm management via Web Engine
Summary The crash has been fixed by reducing the lock time. Now, the generation of the alarm update via service hub (calls user administration to retrieve the full user name) is done outside the lock. Description The crash has been fixed by reducing ...
Changing Alarms/Events via ServiceGrid API fails if the alarm/event is no longer available in binary files
Summary The read-back-single-item-mechanism was repaired for external storage of AML and CEL. Setting comments on alarms and events, setting alarm causes and acknowleding alarms works now as expected when only external storage is active (except for ...
Data Storage evacuation stops working and won't fix itself once the connection to the Data Storage gets interrupted
Summary Retry to write meta data after loss of connection did not work and was now implemented to fix this bug. Description Retry to write meta data after loss of connection did not work and was now implemented to fix this bug. Information Restart ...
Archive data display bug when using Data Storage for archive evacuation
Summary Reading back data storage evacuated variables set some meta information the ETM consumes incorrectly. Now this information is set correctly and the data is displayed as expected. Description Reading back data storage evacuated variables set ...
Ensure maintainability between Supervisor/Analyzer and Service Grid due to different life cycles
Summary Issue Number: 228072 Fixed on Date: 0.0.0 Versions: 10 0 BUILD 85877
SG Ingress Connector: reload issue - consumer receives no values until timeout
Summary The contents of the Service Grid Ingress Connector started up before the connection to the Data Hub was entirely established. Thus, not all objects were correctly connected and the Web Engine request for advising variables was rejected. Now, ...
Usage of time filter with ETM screen should not start the refresh again if refresh is deactivated/stopped before the filter screen is used to show historic data
Summary Applying a filter with refresh reate > 0 re-starts ETM refresh Description Applying a filter with refresh reate > 0 re-starts ETM refresh Information You can use 2 different ETM screens. One is with an refresh rate, and one is used with a ...
Sporadic Timeout of the Metadata-Synchronizer
Summary The timeout for metadata synchronization can now be configured in zenon6.ini: [MetadataSynchronizer] TimeoutMilliseconds=<> Details for the ini setting values: default = 10000 minimum = 200 maximum = 180000 violating values will be clamped to ...
Sporadic exception executing AddIn Wizard in Engineering Studio which modifies SystemModel
Summary Sometimes accessing equipment model via API causes an exception after equipment model has been imported via XML Description Sometimes accessing equipment model via API causes an exception after equipment model has been imported via XML Issue ...
Beckhoff NG driver: if driver is set in simulation mode and afterwards in hardware mode, then change of variable value via set value function trigger in plc is not possible ; not recognized via plc ; general error 6
Summary - Description - Issue Number: 241839 Fixed on Date: 5.8.2021 Versions: 8.20 0 BUILD 87225 | zenon Analyzer 3.40 0 BUILD 87645 | 10 0 BUILD 87728 | 8.00 0 BUILD 88189 | 8.10 0 BUILD 88647 | 7.60 0 BUILD 88730
3D Configurator: no possibility to replace a 3D model / variable + function references are lost
Summary Re-importing STEP file deletes existing variable and function references. Description Re-importing STEP file deletes existing variable and function references. Information no workaround exists... What has been tried so far: A renaming of the ...
Primary Key setting in Metadatabase cannot handle 2 values in the same Timestamp
Summary The second fractions were cut away inside the main stored procedures of the reports. The connectors themselves have always supported second fractions. All report templates in these themes now support second fractions: Custom Formula Analysis ...
AML entries with dynamic alarm text are not represented in 8.10 Webclient correctly when the Server is using 7.11 (Incompatibility)
Summary Client cannot display alarm messages containing extended dynamic limit text from server 7.11 or earlier Description Client cannot display alarm messages containing extended dynamic limit text from server 7.11 or earlier Issue Number: 243233 ...
The OPC UA Driver cannot reconnect to zenProcGateway
Summary Upon timeout, the list of advised variables was emptied. This is no longer done at that point. Description Upon timeout, the list of advised variables was emptied. This is no longer done at that point. Issue Number: 242938 Fixed on Date: ...
LON_32: When there are multiple driver instances, some of the driver-variables do not show status and values in the runtime
Summary Depending on the configuration of a LON-Project, the driver is able to open a connection if the setting is OK. If a single connection fails on opening an exception is thrown but not shown as a message in the diagnose-window, because the ...
AML export to SQL consumes very much memory leading to service engine crash
Summary AML and CEL export to SQL consumes very much memory Description AML and CEL export to SQL consumes very much memory Issue Number: 243744 Fixed on Date: 18.8.2021 Versions: zenon Analyzer 3.40 0 BUILD 87645 | 10 0 BUILD 87728 | 8.20 0 BUILD ...
AccessOPCUA.dll: Gateway generates duplicated MonitoredItemNotifications
Summary The AccessOPCUA server no longer sends duplicate MonitoredItemNotifications in one responce. Description The zenon OPC UA Process Gateway generates duplicate notifications for Monitored Items for a single value change of a variable. This ...
Columns flags changed in ScreenSwitch functions after zenon project conversion
Summary Configured AML/CEL columns in screen switch function get lost if project from version below 10 is converted Description Configured AML/CEL columns in screen switch function get lost if project from version below 10 is converted Issue Number: ...
Next page