Recent Topics
Error during license update
Hello Team, I am facing an error when I am trying to update my license from 1 year to lifetime using Wibucmrau file. I have attached the screenshot below. Please suggest. This is a migrated post! Originally posted on 08.09.2018 by user joelprasad. Please
Maximum Number of bytes will be polled (Read) by zenon in S7TCP driver - Profinet network for each priority (Normal, high, higher, highest) variables
Hello Team, I want to calculate the variable update (read) time by zenon based on priority set for more than 1000 variables. i.e. how much time it will take to update the variable value in zenon for variables which are prioritized as Normal, high, higher,
Project wizard extension in eigenem Thread ausführbar?
Hallo, Ich nutze VS2017 um ein "project wizard extension" zu erstellen. Im wesentlichen führe ich eine Bildumschaltefunktion aus und mache anschließend einen Screenshot. Im debug-Modus aus VS2017 heraus funktioniert alles einwandfrei, weil scheinbar das
F_DELETE false
How to figurout why file wont delete? Image attached. This is a migrated post! Originally posted on 06.09.2018 by user klasik. Please be aware that information can be outdated.
Alarm-Quittiervariable absetzen nach Verbindungsverlust SPS-Treiber Open Modbus TCP
Hallo, über die Alarmverwaltung von Zenon (v7.60 Build 49005) quittiere ich, mit Hilfe der steuernden Quittiervariable eines Alarms (Quittierwert 1), eine auf TRUE / 1 gesetzte Störungvariable in einer SPS (ABB AC500 PM583-ETH) wieder zurück auf FALSE
Webserver with Zenon Operator
Hello Team, Does Zenon Webserver works with Zenon Operator? This is a migrated post! Originally posted on 01.09.2018 by user joelprasad. Please be aware that information can be outdated.
Workspace restore error
Hi, I was trying to restore a workspace backup but getting the error always. I have tried this in another laptop but same situation any one can help? Sandy This is a migrated post! Originally posted on 30.08.2018 by user sandeep2018. Please be aware that
Zenon operator station
Hi, I would like to know how to create a zenon operator in my project. I am planning to use 15'' IPC with I3 for the operator station any guidance for this would be appreciated Regards Sandy This is a migrated post! Originally posted on 28.08.2018 by
Error while giving open command ti the RTU IEC 608710 104 Protocol
Hello Team, I am not able to send open command to the RTU in IEC 60870 protocol from the SCADA. I am able to send the close command though. I tried the same thing using a IEC 104 simulator and I was able to send both the commands open and close. While
Oee
Hi, I would like to know if there is any templates for OEE calculation in Zenon copadata Regards Sandy This is a migrated post! Originally posted on 26.08.2018 by user sandeep2018. Please be aware that information can be outdated.
Modbus Process Gateway Error
We are using Modbus Process Gateway to transmit values to the DCS system. The DCS can receive information from Gateway, but once the DCS sends command to Gateway, Gateway terminated with error: Exception code: E06D7363 Fault address: 74A74598 01:00013598
Driver Mode Switching recommendation?
Dear Team, I'm using Zenon 7.50 Build 49034 and multi-project structure with Three different drivers. I want to stop communication when no communication from controller kindly suggest Driver Mode switching Functions 1.For starting Driver ----> a) Driver
Siemens PLC to Zenon - Variable update time delay in S7TCP driver - Profinet network
Hello, In my project i am using Siemens CPU 319 and in zenon S7TCP driver was used to communicate with PLC in Profinet network. Total 4200 PLC variables are created in Zenon. Out of 4200 variables 1200 variables are used as permanently read variable.
Permanently read variable
Hello Team, If a variable is enabled for permanently read variable how is that variable polled by Zenon. (Time interval)? This is a migrated post! Originally posted on 24.08.2018 by user joelprasad. Please be aware that information can be outdated.
Error while importing cfg file in comtrade viewer
Hello Team, I am facing an error while I import the .cfg file in the Comtrade viewer. I have attached the screenshot below. Please suggest a possible solution. It happens when I click on open button and select the .cfg file from the extraction folder.
Unsolicited DNP3 Communication with Zenon 8.0
Dear Support, I am getting the unsolicited messages when my RTU connected to in ASE Tool as Master. However, I am unable to get the Unsolicited message frm same RTU in Zenon runtime v8.0 . I am attaching the Zenon DNP3.0_TG Driver setting i did, for your
Default Function "Display unused variables" have problem
Dear Team, I'm using Zenon 7.50 Build 49034 and multi-project structure. When I active 1st project and select default Function "Display unused variables" it will not show all the filters within the project. Next if i active 2nd project and select default
Recipe combobox not refreshing after create
Hi, I'm trying to modify an existing recipe name from code-behind and also create a new recipe. The changes seems to update after i switch back to the standard recipe page. But the recipe page does not update its content (like the combobox) while the
SQL export
Hi I use the SQL export function in zenon 7.6 but I have 2 question : + When zenon automatic export archive to SQL by cycle or change values or should has function to export archive to SQL + The table are created in SQL by Editor different than the table
Alarm Sound bei Störmeldung
Hallo, ich bin auf der suche nach verschiedenen Alarm Tönen? Bietet Zenon da keine eigenen Sounds? This is a migrated post! Originally posted on 16.08.2018 by user crz. Please be aware that information can be outdated.
Runtime Hangs when pressing Button
Hi everyone, I am currently evaluating Zenon 8.00 since our company is looking for a new HMI that can be used in our electric industry. I am very new to Zenon 8.00 and I am currently going through the firststeps PDF provided with the software. I have
S71200 error
Hi, I have created a sample project in TIA V13 and tried to communicate with Zenon 8.0 but no communication. Attached the diag viewer This is a migrated post! Originally posted on 13.09.2018 by user sandeep2018. Please be aware that information can be
Iec60870 104 slave driver process gateway
Hello Team, I am using IEC60870 104 fieldbus in zenon logic as slave as a process gateway. I have added certain no. of IEC61850 double point information to the gateway. Now in the client side of the gateway I am getting readings like shown below: For
Edit formula of MATH Variables
Dear Support Please suggest and provide a sample code on how to edit the formula section of the Math variables. I want to add Variable, select Formula definition and add actual Formula by vba. Best Regards Sarfaraz This is a migrated post! Originally
Communication with AB PLC
Hi, i have three PLC's to be interfaced with Zenon Copadata. Please advice the best option for this 1.Allen Bradley-Compact Logix L35E 2.Allen Bradley-SLC 5/04 3.Allen Bradley-Micrologix 1500 Regards Sandeep This is a migrated post! Originally posted
SNMP Driver memory issue
Hello Support, I have one doubt for SNMP driver, How many IED we can add in single SNMP driver ? A large memory (CPU & memory) used by this driver. I want to minimize it. For Example, I have 16 switch, so how many driver i have to create so that system
Comtrade viewer issue
Hello Team, Even after licensing using energy license it shows this message'No energy edition license found' on the comtrade viewer. I have attached the screenshot. Please suggest This is a migrated post! Originally posted on 08.08.2018 by user joelprasad.
Funktion ruft Script nicht auf
Hallo, Wir haben VBA Scripte die Werte in eine Text-Datei schreiben. Diese Scripte werden durch eine Funktion aufgerufen. Die Funktion wiederum wird durch den Grenzwert 1 der Variabel aufgerufen. Mit ein paar Anpassungen habe ich das als Vorlage für ein
Zenon Remote Runtime Driver Issue
Dear Team, i have been trying to communicate to low version to High version and vice-versa. Having more problem in Zenon 7.50 ,7.60, 8 version After multiple trails then communication is being establishing. Provide solution as soon as possible Regards
zenDBSrv.exe is not responding
I have been using zenon versions 7.50 and 7.60 . facing issue in standard of version . I have been forcibly stopping zenDBSrv.exe and then my version is being standard kindly provide me solution as soon as possible Regards Diana John This is a migrated
Zenon New Build Numbers 7.50, 7.60
Dear Team, I have been using Zenon from long time. Its great to see support team is additional helping all the engineers using forum. I wish to know the latest Build number of Zenon Versions 7.50 and 7.60 . Kindly share me the link as soon as possible
Error message popup from windows everytime I open and close Zenon energy runtime
Hello Team, I am facing an error every time I open and close Zenon Runtime. Although it does not affect the functionality of the runtime. In the beginning when the error comes, I close the dialog box and the runtime works perfectly. Any suggestions why
Screen selection
Hi, I am new to zenon scada and trying to learn about the software. I created two screens ie Main screen and Menu bar with different frame but when I run application only main screen displays and Menu bar not visible. How can i combine this ? Regards
Shift Management: Unexpected crash on IShifts.GetItem
Hi guys, I'm having big troubles with shift management. In my app I have these few lines that reads informations from the Calendar in order to keep track of "today" shifts. _shiftsToday = shiftFilter.GetShifts();
if (_shiftsToday != null)
{
IShift
Communication with IEC 61850 edition 1 and edition 2 simultaneously
Hello team, While communicating with IED Devices of both IEC 61850 Edition 1 and edition 2 simultaneously, is there any prerequisites/necessary settings that needs to be taken care off? Can both the Edition devices communicate with the same IEC 61850
Zenon to Siemens PLC Tag writing delay
Hello, In my project i have used Siemens CPU 319 and it is connected with Zenon Supervisor. With PLC i have connected many devices via profinet and Zenon supervisor too. Total no of PLC tags is 4500. Here i have recipe (RGM) and datalogging to MSSQL using
Copy Extended Trend between clients
Hi Support, I created filters in my extended trends screen (see picture attached, for example: G3_YUNCAN) in my client computer. Now i want to copy these filters to another client computer (I donÂ't want do it again, because there are a lot of filters),
Lot filter interaction
Dear all, I am trying to perform a combination of a lot filter, trend and report viewer in the same screen (currently using 7.20 version) They work well individually but I do not know how to get the name of the selected lot in the filter. Once I get it
Service - memory leak
Hello, Our service reads some data from archive each minute (using Thread). But when this service is running, Runtime memory increases continuously. Could someone help me to detect, what is wrong with this part of code: public class ServiceExtension :
VBA funktioniert nicht im WebClient
Hallo, wir haben das Probelm, dass in unserem Webclient kein VBA Code ausgeführt wird. Wir nutzen Zenon 8 (64Bit) auf einem WindowsServer 2016 Standard und zur Anzeige des WebClient den WebClientStarter auf Windows 10 (64Bit) PC's. In der zenon6.ini ist