Recent Topics
How PLC Input and Output variables will be shared between Zenon RT and VSTA while macro is executing?
Hello, Please clarify me about how PLC Input variables will be updated between PLC --> Zenon RT --> VSTA and for output VSTA --> Zenon RT --> PLC while macro is executing? For example, i am triggering VSTA macro in RT using reaction matrix and it is started
Monitor Administration (2 monitors)
Hello everybody, I'm working on Zenon Operator 7.50 / Windows 10. I need to have 2 monitors in project (both with fullhd resolution 1920x1080). I have read Monitor Administration Zenon manual. I need to show Screen0 on monitor1 (left) and Screen1 on monitor2
Report Viewer colours
Hi, I'm looking for a way to make a colours' palette working on a chart in which I haven't series but only values and category groups. I would like to know how to set the palette also for the groups and not only for the series. Thank's for the help. This
IEC61850 Driver - Report control blocks - Communication Problem
I'm working on Zenon Operator 7.50. I have read IEC850 Zenon Driver Manual. I need to connect to a device via IEC61850 protocol. I detected 2 different working case: CASE 1: if my device doesn't include REPORT CONTROL BLOCKS -> ZENON reads variables from
compare runtime files and backup
Hi, We need to make some changes on running zenon 7.00 system with 2 servers and 2 clients. We have a backup that we restore on a development station but we are not sure if this is the final revision. So is there a way to compare runtime files on servers
Remiving a Zenon project from the Server
I have a question: How can I remove an existing ZENON project from a server machine without removing the ZENON Supervisor environment? Thanks for your attention. Stefano This is a migrated post! Originally posted on 03.10.2017 by user stepau. Please be
Zenon 7.60 mit Win10 und Office 365 Editorcrash
Hallo, Zenon 7.60 (aktuelle Build) crasht in Windows 10 wenn auf dem gleichen System auch Office 365 installiert ist. Lokaler Support wurde informiert und das Problem müsste auch an die Entwicklungsabteilung weitergeleitet worden sein. Meine Frage: bis
IEC61850 Driver - Data Type
Hello everybody, I'm working on Zenon Operator 7.50 In my project I need to connect N devices of same type. Each device is defined in Zenon like 61850 server with different net address. I'm using symbolic addressing and the import of variables from driver
Problem with Version Control
Hi, Is there anyone using Straton with SVN client? I got problem with it and find no instruction in Straton Help. After installation of Zenon 7.60 on my PC (Win7), I created a Staton project and enabled the Version Control in Project Setting. There I
Problem with Autotstart project in Straton Runtime Manager
Hi, The Autostart project (Straton Runtime Manager) does not work on some of my computers. Does anyone know if there are any registry setting in Windown 10 that prevent Staton Autostart? This is a migrated post! Originally posted on 11.10.2017 by user
Anyone using Straton with Hilcher gateway on Profinet IO?
Hi, I am trying to using Hilcher gateway NT50-DP-PN (profibus DP to Profinet IO Device) with Straton PLC. I set up and Profinet IO Controller in Straton and try to connect to Profinet IO Device (Hilcher gateway) but did not suceed. The Straton alway return
IEC61850 Timestamp
Hello Support, I am using IEC61850 protocol which supports time stapm to read data from SEL 451 relay using buffered reports, the problem is that i am receiving timestamp from the relay with wrong timestamp ( miliseconds in difference). Please advise.
How can I manipulate the elements of a GIS control Activex?
Dear How can I manipulate the elements (context menu with linked zenon function) of a GIS control Activex? For example in the attached image in the GIS control Activex I have the context menu named "SET01_O-242_5", I would like through VBA O C# to manipulate
Straton runtime not starting.
Straton is showing an error 'embedded software missing function: ICOPY'. Please help me with this, as it is causing a big issue now This is a migrated post! Originally posted on 14.10.2017 by user joelprasad. Please be aware that information can be
Mitsubishi fx-5u plc communication
CAN ANYONE KNOWS WHICH DRIVER USED FOR MITSUBISHI IQ-F (FX-5U) PLC ,AND SEND THE BACKUP OF PLC AND SCADA This is a migrated post! Originally posted on 16.10.2017 by user saikumar. Please be aware that information can be outdated.
Modbus Slaves keine Verbindung
Hallo Zenon-Team, ich habe ein Problem beim Abrufen von Prozesswerten über Siemens Energiezählers vom Typ PAC 3100 welche als Modbus Slave an einem PAC4200 als Gateway hängen. Wenn ich den Modbustreiber so konfiguriere dass das Gateway als Netzadresse
VBA Import Equipement Modeling
I don't find how i can import with VBA equipement modeling XML file This is a migrated post! Originally posted on 17.10.2017 by user johanngrimaud. Please be aware that information can be outdated.
WPF and Adorners
Hello, My task is to implement a .NET based WPF control including a more or less complex chart. The chart contains a zoom and pan functionality for zooming in, zoom out, scoll and pan within the chart area by using the left/right mouse buttons. In the
Import historischer Daten in zenon Archiv
Hallo, aktuell entwickle ich .NET Module (VSTA und WPF) für die zenon 7.60 Umgebung unter Windows 10, die Archivdaten über mehrere Monate auswertet. Der Kunde hat noch keine realen Archivdaten verfügbar (CD Kunde seit Anfang des Jahres) und wird die Lösung
IEC61850 Driver - Time Synchronization AML CEL
I'm working on Zenon Operator 7.50 In my project there are two type of 61850 IED device, both can support SNTP synchronization. In the pc where Zenon is running the changing of summer time is disabled and time zone is set +00:00. In AML and CEL Received
ALC Source
Hi I have a question for ALC for power transformer? That the ALC sources can come from each sides of transformer and change different color for each sides. I tried to use link to connection between sides but it did not work. I read the manual and tried
Connection to Codesys v.3 PLC
Hi, I'm trying to connect to a Codesys v.3 PLC (Festo CPX-CEC-C1-v3 and Festo CECC) from Zenon Supervisor 7.20 sp 0 build 18778 installed on Win 7 x64 sp1 Ultimate. Codesys 3.5 incl. Gateway, SoftPLC and everything else is installed on the computer. This
Show Array Char to String
Hi All, i'm using Zenon editor 7.60. Importing Variables from the PLC S7-1200, PLC STRING values become, in my Zenon variables, Char Array (USINT Array). Now I would like to view these Arrays in a Link Text element (such as a String), but it does not
Recipe: View Bool Variable ON/OFF mode
Hi All, I'm using a Standard Recipe in the Zenon project 7.60: Some recipe ingredients (variables) are BOOL type and are shown with 0 and 1. There is a possibility to show in the Recipe Listbox these Variables in "ON / OFF" mode? (I tried by using a Reaction
Accessing variables in Runtime wizard and service
Hello, I have been trying to migrate some of the VSTA functionality to the Add-In Framework for Visual Studio 2017 in Zenon 7.60 but I am not sure how to do this. I was looking for the same functionality as it was avaliable in the VSTA to access, read/write
List of running Addins
Hello, is it possible to access a list/container of the running RunTime AddIn's resp. a reference to the running AddIn objects. Best regards This is a migrated post! Originally posted on 18.10.2017 by user Ruebezaehler. Please be aware that information
Interlockings
Hello, I have a problem with the interlockings module. It looks like in case that one of the variables is INVALID, The interlock will not work. Also what is strange is that the INVALID statusbit is not shown in the uncollapsed list of the statusbit, but
Web Server problems
Hi. I'm using Zenon Energy Edition 7.20 and now I need to start my project application using Web Server. I have install Web Server as it is written in Zenon Web Server Manual and like it was shown on Youtube video Zenon web server (official COPA DATA
Multithreading Thread safety
Guten Tag, ich plane eine "PROJECT SERVICE EXTENSION", in welcher das Lesen von Variablen, als auch das Schreiben auf Variablen in einem anderen als dem UI-Thread geschehen soll. Koennen die GetValue/SetValue direkt benutzt werden oder muss das Lesen
Zenon 6.51 runtime in windows embedded standard 7 WES7
Hello, we have project in zenon 6.51 sp 0 and need to install runtime in an panel pc 2100 B&R with windows embedded standard 7 is it possible? what should I do? where can I get files to install in the panel? regs, martin This is a migrated post! Originally
Symbol Library
Hello all, I created a symbol in the symbol library and then used this symbol 10 times in screens. This is a button. A client asked to change the color of the button. So I changed the color of a symbol in the symbol library, but the color on the screens,
Dnp3 proccess gateway with classes
Dear support, with zenon 7.5 or 7.6 can we define class for each variabel using dnp3 proccess gateway.dose it support defining different calsses for different variables? This is a migrated post! Originally posted on 26.10.2017 by user yazan. Please be
Webserver in internet environment
I am using webserver in the internet environment. I have installed a firewall for better security and I am opening port 1102 in the firewall for webclient-webserver access. I am not able to get a good communication between webserver and webclient. While
Umbenennen von Unterprojekten
Hallo, ich versucher aktuell vergeblich bei einem Unterprojekt den Projektnamen zu ändern. Ich gehe wie folgt vor: Rechtsklick auf Projekt -> "Projekt" -> "Umbenennen..." Dabei passiert aber nichts. Wie kann ich den Namen ändern? Schöne Grüße This is
Not able to set up web client
I am not able to set up web client from the index page http://www.publishingserver.com//zenon/index.htm. The browser shows "This page can’t be displayed ". Please suggest a solution. I have tried in IE, Chrome and Firefox. I have added it to the trusted
How to change numeric display on round slider
Hello guys, I am using zenon v7.20 operator and created a CE project which has a round slider to show the angle of a press slider. I need to show the number "0/360" at the top and "180" at the bottom. However in the properties I only managed to configre
Message control
hello; we have a project where we have to use message control module option in order to send messages (alams) via SMS using GSM modem . I'm looking for any reference ( demo project) where this solution was used with examples, because we never used this
Writing status bits on Zenon Logic Global Variables
What kind of status bits are settable from Zenon Logic on Global variables? I've found that none of M1..M8, ALT_VAL are settable (or almost are not visibile from Zenon Runtime) I'm using STRATONNG driver. This is a migrated post! Originally posted on
Set M1..M8 on StratonNg variables, only via recipe?
Is not possible to set M1..M8 status bits via Api/COM interface? This is a migrated post! Originally posted on 03.11.2017 by user maurodx. Please be aware that information can be outdated.
zenon_startup.exe - System Error
Hi Zenon Community, I have Installed Zenon 7.50 Build 30617 at my Windows Server 2012 R2. Setup was successfully installed but when i tried to open Zenon Startup Tool or Editor the following error appears- "The program can't start because api-ms-win-crt-convert-i1-1-0.dll
Next Page