Recent Topics
IEC101 error
Hi Could you give me some idea that I use 101 master connect to Process gateway, but after connected , I receive old value ( display with previous time tag), and after few minute , it disconnected. My log file has comment : The previous frame was resend
Waterfall WPF online diagram configuration
Hello, I would like to generate a online Waterfall diagram at the Zenon Editor but i am unable to generate the configuration via the Wizard I am using "Wizards.pdf" / "3.1.5 Meaning and Waterfall Chart Wizard" documentation. The settings are "Define Waterfall
Importing of values from text file to Runtime
Hi Guys I am taking few data from the IED through FTP. The Data are present in the the Text file. I want to read the values from that Text file into the Runtime and store in our historian. Is there any solution or suggestion?? This is a migrated post!
Report-Visual Studio
I’m new in Zenon and I’m using the Report Viewer (Repor-Visual Studio) tool in Zenon Supervisor. I have a dataset with some variables and I’m trying to make a chart. I’m writing in the expression the code to visualize the value, but it only shows
Error with function structure member.
Hello, Iam programming with the IDE Straton. Iam trying to use 2 structure parameter, one 'IN' and one 'OUT'. The types of the structures are the same ACCE_QUALITY. ACCE_QUALITY : - validity : BYTE - detailQual : ACCE_DETAIL_Q - source : BYTE - test :
Problem with ICCP Gateway
Hello, I can't find the Transport Selectors (TSEL) value in the zenProcGateway.INI. Where can adjust that value? This is a migrated post! Originally posted on 31.08.2017 by user glopez. Please be aware that information can be outdated.
Installation Interrupted and closed (Zenon EE 6.11 SP0)
Dear Support, While trying to install Zenon EE 6.11 SP0 on Windows 7, the SQL installation finishes successfully but immediately after that the installation window displays the message "Installation was interrupted and will close.". (Screen shot is attached,
DBF Dateien nochmals Auslagern
Hallo zusammen, ist es möglich, ausgelagerte Archivdateien im Format DBF nachträglich (nochmals) auszulagern und zwar diesmal als CSV-Datei? Hintergrund: In den DBF-Dateien ist die Zeichenanzahl pro Spalte begrenzt (so um die 32), so dass es mir die Variablennamen
Reportin-Alarms
Hi, I'm looking for a solution to report some alarm variables. I have lots of variables in my project setted as alarms (not in the historian, only in the variables section), if there is something wrong even here, please tell me. I'm trying to make some
Alarm storing
Hi, I'm trying to report all the alarms in a plant. The AML is working well and I'm reporting in Report-viewer the alarms. I can only report alarms in the buffer ring, so as soos as someone resets the alarm, the data about that alarm is lost and it isn't
Multi Monitor
Hello everybody, I'm working on Zenon Operator 7.50. I have 3 monitosr (M1[FULL-HD]: 1920x1080, M2[FULL-HD]: 1920x1080, M3[16:10]: 1920x1200). The monitors will show different pages. I have read Monitor Administration Zenon Manual. My question is: case
Schriften in globalen Symbolen (v7.60)
Hallo, ich bin gerade auf ein Problem bei der Konvertierung eines 7.0 Projektes in v7.60 gestossen. Allgemein werden ja eingebettete Schriften in v7.60 nicht mehr unterstützt. In Bildern und Symbolen, die zu einer Projekt-Symbolbibliothek gehören ist
COPA-DATA Developer Tools für Visal Studio 2017?
Hallo! Ich wollte hier mal kurz nachfragen ob es schon einen Aussicht für die Nutzung von COPA-DATA Developer Tools unter Visual Studio 2017 gibt? Da ich nur Visual Studio 2017 auf dem Rechner habe bin ich momentan etwas ausgebremst, da ich mich eigentlich
IEC61850 Driver - Connection State
I'm working on Zenon Operator 7.50. I have define IEC 61850 Driver with 4 server (ref to fig). Everything is working fine. My question is: where can I find the connection state of each server? in which variable? Thank you, Andrea This is a migrated post!
ConnectionState
Hello, I try to visualize the state of the 61850 connection by means of a dynamic text symbol. The text symbol is set to present the limit text of the value of the connectionstate variable. The connectionstate variable has the rema "IEC 61850 Connection
File transfer in zenon-7.5 with IEC_61850
Hello Copadata support, I am trying file transfer between an IEC-61850 device and Zenon 7.5. Could anyone support? Thanks in advance This is a migrated post! Originally posted on 13.10.2017 by user saravanan1985. Please be aware that information can be
Driver Simulation Project - 61850 variables
Hi, I have a Zenon project in which there is a 61850 driver, with its own variables (variables name according to the standard). I want to use Driver Simulation Project, so in driver property I activated Mode: Simulation - Programmed. Problem appears in
MouserOver on button
Hi, I want to add a mouseOver effect on buttons using VBA. So far my code goes as follows : VBA Code: Public Sub MouseOver_Color(obElem As Element, vPosX As Variant, vPosY As Variant) obElem.BackColor = RGB(246, 152, 4) obElem.ForeColor = RGB(255, 255,
Alarms dynamic change
Hello, I was wondering is there a way to add / remove alarms while the zenon runtime is active. For now every time I need to change a variable with alarm attribute I need to stop and start the runtime.... This is a migrated post! Originally posted on
Custom filter
Hi, I'd like to make a filter for my reports. I always used templates to do my filters. Now I need something more "home-made", I can't figure out how to make a proper one. I need a filter with a selection of the date that I desire and then I also need
Ascending CEL problem
In 7.60 build 39532. Presenting events ascending (last event under) does not work as in previous versions. So in case the event list is full and a new event comes. It wil not appear on the last line but you have to scroll down to get the event in the
How PLC Input and Output variables will be shared between Zenon RT and VSTA while macro is executing?
Hello, Please clarify me about how PLC Input variables will be updated between PLC --> Zenon RT --> VSTA and for output VSTA --> Zenon RT --> PLC while macro is executing? For example, i am triggering VSTA macro in RT using reaction matrix and it is started
Monitor Administration (2 monitors)
Hello everybody, I'm working on Zenon Operator 7.50 / Windows 10. I need to have 2 monitors in project (both with fullhd resolution 1920x1080). I have read Monitor Administration Zenon manual. I need to show Screen0 on monitor1 (left) and Screen1 on monitor2
Report Viewer colours
Hi, I'm looking for a way to make a colours' palette working on a chart in which I haven't series but only values and category groups. I would like to know how to set the palette also for the groups and not only for the series. Thank's for the help. This
IEC61850 Driver - Report control blocks - Communication Problem
I'm working on Zenon Operator 7.50. I have read IEC850 Zenon Driver Manual. I need to connect to a device via IEC61850 protocol. I detected 2 different working case: CASE 1: if my device doesn't include REPORT CONTROL BLOCKS -> ZENON reads variables from
compare runtime files and backup
Hi, We need to make some changes on running zenon 7.00 system with 2 servers and 2 clients. We have a backup that we restore on a development station but we are not sure if this is the final revision. So is there a way to compare runtime files on servers
Remiving a Zenon project from the Server
I have a question: How can I remove an existing ZENON project from a server machine without removing the ZENON Supervisor environment? Thanks for your attention. Stefano This is a migrated post! Originally posted on 03.10.2017 by user stepau. Please be
Zenon 7.60 mit Win10 und Office 365 Editorcrash
Hallo, Zenon 7.60 (aktuelle Build) crasht in Windows 10 wenn auf dem gleichen System auch Office 365 installiert ist. Lokaler Support wurde informiert und das Problem müsste auch an die Entwicklungsabteilung weitergeleitet worden sein. Meine Frage: bis
IEC61850 Driver - Data Type
Hello everybody, I'm working on Zenon Operator 7.50 In my project I need to connect N devices of same type. Each device is defined in Zenon like 61850 server with different net address. I'm using symbolic addressing and the import of variables from driver
Problem with Version Control
Hi, Is there anyone using Straton with SVN client? I got problem with it and find no instruction in Straton Help. After installation of Zenon 7.60 on my PC (Win7), I created a Staton project and enabled the Version Control in Project Setting. There I
Problem with Autotstart project in Straton Runtime Manager
Hi, The Autostart project (Straton Runtime Manager) does not work on some of my computers. Does anyone know if there are any registry setting in Windown 10 that prevent Staton Autostart? This is a migrated post! Originally posted on 11.10.2017 by user
Anyone using Straton with Hilcher gateway on Profinet IO?
Hi, I am trying to using Hilcher gateway NT50-DP-PN (profibus DP to Profinet IO Device) with Straton PLC. I set up and Profinet IO Controller in Straton and try to connect to Profinet IO Device (Hilcher gateway) but did not suceed. The Straton alway return
IEC61850 Timestamp
Hello Support, I am using IEC61850 protocol which supports time stapm to read data from SEL 451 relay using buffered reports, the problem is that i am receiving timestamp from the relay with wrong timestamp ( miliseconds in difference). Please advise.
How can I manipulate the elements of a GIS control Activex?
Dear How can I manipulate the elements (context menu with linked zenon function) of a GIS control Activex? For example in the attached image in the GIS control Activex I have the context menu named "SET01_O-242_5", I would like through VBA O C# to manipulate
Straton runtime not starting.
Straton is showing an error 'embedded software missing function: ICOPY'. Please help me with this, as it is causing a big issue now This is a migrated post! Originally posted on 14.10.2017 by user joelprasad. Please be aware that information can be
Mitsubishi fx-5u plc communication
CAN ANYONE KNOWS WHICH DRIVER USED FOR MITSUBISHI IQ-F (FX-5U) PLC ,AND SEND THE BACKUP OF PLC AND SCADA This is a migrated post! Originally posted on 16.10.2017 by user saikumar. Please be aware that information can be outdated.
Modbus Slaves keine Verbindung
Hallo Zenon-Team, ich habe ein Problem beim Abrufen von Prozesswerten über Siemens Energiezählers vom Typ PAC 3100 welche als Modbus Slave an einem PAC4200 als Gateway hängen. Wenn ich den Modbustreiber so konfiguriere dass das Gateway als Netzadresse
VBA Import Equipement Modeling
I don't find how i can import with VBA equipement modeling XML file This is a migrated post! Originally posted on 17.10.2017 by user johanngrimaud. Please be aware that information can be outdated.
WPF and Adorners
Hello, My task is to implement a .NET based WPF control including a more or less complex chart. The chart contains a zoom and pan functionality for zooming in, zoom out, scoll and pan within the chart area by using the left/right mouse buttons. In the
Import historischer Daten in zenon Archiv
Hallo, aktuell entwickle ich .NET Module (VSTA und WPF) für die zenon 7.60 Umgebung unter Windows 10, die Archivdaten über mehrere Monate auswertet. Der Kunde hat noch keine realen Archivdaten verfügbar (CD Kunde seit Anfang des Jahres) und wird die Lösung