Recent Topics
IEC61850 Driver - Time Synchronization AML CEL
I'm working on Zenon Operator 7.50 In my project there are two type of 61850 IED device, both can support SNTP synchronization. In the pc where Zenon is running the changing of summer time is disabled and time zone is set +00:00. In AML and CEL Received
ALC Source
Hi I have a question for ALC for power transformer? That the ALC sources can come from each sides of transformer and change different color for each sides. I tried to use link to connection between sides but it did not work. I read the manual and tried
Connection to Codesys v.3 PLC
Hi, I'm trying to connect to a Codesys v.3 PLC (Festo CPX-CEC-C1-v3 and Festo CECC) from Zenon Supervisor 7.20 sp 0 build 18778 installed on Win 7 x64 sp1 Ultimate. Codesys 3.5 incl. Gateway, SoftPLC and everything else is installed on the computer. This
Show Array Char to String
Hi All, i'm using Zenon editor 7.60. Importing Variables from the PLC S7-1200, PLC STRING values become, in my Zenon variables, Char Array (USINT Array). Now I would like to view these Arrays in a Link Text element (such as a String), but it does not
Recipe: View Bool Variable ON/OFF mode
Hi All, I'm using a Standard Recipe in the Zenon project 7.60: Some recipe ingredients (variables) are BOOL type and are shown with 0 and 1. There is a possibility to show in the Recipe Listbox these Variables in "ON / OFF" mode? (I tried by using a Reaction
Accessing variables in Runtime wizard and service
Hello, I have been trying to migrate some of the VSTA functionality to the Add-In Framework for Visual Studio 2017 in Zenon 7.60 but I am not sure how to do this. I was looking for the same functionality as it was avaliable in the VSTA to access, read/write
List of running Addins
Hello, is it possible to access a list/container of the running RunTime AddIn's resp. a reference to the running AddIn objects. Best regards This is a migrated post! Originally posted on 18.10.2017 by user Ruebezaehler. Please be aware that information
Interlockings
Hello, I have a problem with the interlockings module. It looks like in case that one of the variables is INVALID, The interlock will not work. Also what is strange is that the INVALID statusbit is not shown in the uncollapsed list of the statusbit, but
Web Server problems
Hi. I'm using Zenon Energy Edition 7.20 and now I need to start my project application using Web Server. I have install Web Server as it is written in Zenon Web Server Manual and like it was shown on Youtube video Zenon web server (official COPA DATA
Multithreading Thread safety
Guten Tag, ich plane eine "PROJECT SERVICE EXTENSION", in welcher das Lesen von Variablen, als auch das Schreiben auf Variablen in einem anderen als dem UI-Thread geschehen soll. Koennen die GetValue/SetValue direkt benutzt werden oder muss das Lesen
Zenon 6.51 runtime in windows embedded standard 7 WES7
Hello, we have project in zenon 6.51 sp 0 and need to install runtime in an panel pc 2100 B&R with windows embedded standard 7 is it possible? what should I do? where can I get files to install in the panel? regs, martin This is a migrated post! Originally
Symbol Library
Hello all, I created a symbol in the symbol library and then used this symbol 10 times in screens. This is a button. A client asked to change the color of the button. So I changed the color of a symbol in the symbol library, but the color on the screens,
Dnp3 proccess gateway with classes
Dear support, with zenon 7.5 or 7.6 can we define class for each variabel using dnp3 proccess gateway.dose it support defining different calsses for different variables? This is a migrated post! Originally posted on 26.10.2017 by user yazan. Please be
Webserver in internet environment
I am using webserver in the internet environment. I have installed a firewall for better security and I am opening port 1102 in the firewall for webclient-webserver access. I am not able to get a good communication between webserver and webclient. While
Umbenennen von Unterprojekten
Hallo, ich versucher aktuell vergeblich bei einem Unterprojekt den Projektnamen zu ändern. Ich gehe wie folgt vor: Rechtsklick auf Projekt -> "Projekt" -> "Umbenennen..." Dabei passiert aber nichts. Wie kann ich den Namen ändern? Schöne Grüße This is
Not able to set up web client
I am not able to set up web client from the index page http://www.publishingserver.com//zenon/index.htm. The browser shows "This page can’t be displayed ". Please suggest a solution. I have tried in IE, Chrome and Firefox. I have added it to the trusted
How to change numeric display on round slider
Hello guys, I am using zenon v7.20 operator and created a CE project which has a round slider to show the angle of a press slider. I need to show the number "0/360" at the top and "180" at the bottom. However in the properties I only managed to configre
Message control
hello; we have a project where we have to use message control module option in order to send messages (alams) via SMS using GSM modem . I'm looking for any reference ( demo project) where this solution was used with examples, because we never used this
Writing status bits on Zenon Logic Global Variables
What kind of status bits are settable from Zenon Logic on Global variables? I've found that none of M1..M8, ALT_VAL are settable (or almost are not visibile from Zenon Runtime) I'm using STRATONNG driver. This is a migrated post! Originally posted on
Set M1..M8 on StratonNg variables, only via recipe?
Is not possible to set M1..M8 status bits via Api/COM interface? This is a migrated post! Originally posted on 03.11.2017 by user maurodx. Please be aware that information can be outdated.
zenon_startup.exe - System Error
Hi Zenon Community, I have Installed Zenon 7.50 Build 30617 at my Windows Server 2012 R2. Setup was successfully installed but when i tried to open Zenon Startup Tool or Editor the following error appears- "The program can't start because api-ms-win-crt-convert-i1-1-0.dll
Zenon 7.60 editor (32 bit or 64 bit) Build 39532 Freezes when started
Hi, I've installed Zenon 7.6 build 39532, when i tried to launch the Editor (x64 or x32) it starts showing the workspace but after that directly freezes and doesn't response at at all. Thanks for you help. This is a migrated post! Originally posted on
Graphic Compile Error
Hello all, I get error messages on my graphic files . Print Screen is attached. What does it means? In Runtime the logos do appear on screens. Olesia. This is a migrated post! Originally posted on 06.11.2017 by user Olesia. Please be aware that information
Import variables from TIA V14 to Zenon 7.60
how can i import variables from a TIA 14 project with zenon 7.60 build Build39532 since PLC. This is a migrated post! Originally posted on 07.11.2017 by user johanngrimaud. Please be aware that information can be outdated.
Get RTC Variable from zenon
hi Support, in my project the plc's (ABB PM554) dont have RTC battery so i want to take a Variable in DT type from the zenon editor to my plc and set the RTC according to that variable. Tank you This is a migrated post! Originally posted on 07.11.2017
Tausender Trenzeichen in Variablen
Hallo, gibt es eine Möglichkeit eine Variable (kWh-Wert) so zu konfigurieren, dass der angezeigte Wert besser lesbar ist? Beispiel: Aktuell wird ein Wert in kWh so angezeigt: 4366514.00 kWh Kann man es auch irgendwie machen dass der Wert so: 4.366.514,00
Beschleunigung Bildaufbau
Bei der Bildumschaltung verzögert sich der Bildaufbau bei Elementen, die eine Sichtbarkeitsvariable enthalten. Gibt es eine Möglichkeit um den Bildaufbau zu beschleunigen? This is a migrated post! Originally posted on 08.11.2017 by user carina.schlicker.
unvollständige Meldung im Ausgabefenster des Editors
Hallo zusammen, wie findet man denn heraus, wer oder was hinter folgender Meldung im Ausgabefenster steckt (beim Erzeugen geänderter Runtime-Dateien im Editor): " ist mit ungültiger Variable 5617 verknüpft" bzw. " ist mit ungültiger Variable 9001838 verknüpft"?
Driver priority within UDT
How does driver priority work with regards to variables that are actually elements of a single structure in the PLC? We're using the Logix_ODVA driver, and virtually all of our variables are structured under a single tag. i.e.: BaseTag.Group1.SubGroup1.VarName1
VSTA-VB.Net - Macro Call Delay and Execution Delay
Hello, I am facing the following delay while executing the macro from VSTA-VB.net code. After my trigger Bool variable is high, 1. Macro is calling after 2 sec and this 2 sec delay is constant for all the trials. 2. Zenon variable from Macro output is
Projekt-GUID für Runtime relevant?
Hallo zusammen, ich möchte die Projekt-GUID von einem Zenon-Projekt ändern, weil ich Probleme mit der Datenbank auf dem Projektierrechner habe. Meine Frage wäre, wenn ich die GUID ändere, ob das Auswirkungen auf die Runtime hat? Also das Zenon-Projekt
Automatically build using the STRATON development environment
Hi, I have a STRATON project (W5L and K5P files). I would like to automatically build the project so that I can check for errors. Is this possible using the automation interface or via the command line? I have the STRATON Development Environment which
How to open PDF file in zenon run time
I need to open manual (PDF file) for my instruments in Zenon screen.. Please let me know how can I do this? This is a migrated post! Originally posted on 12.11.2017 by user azamsyscom@gmail.com. Please be aware that information can be outdated.
Report Viewer Trend über mehrere Seiten anzeigen
Hallo alle zusammen, ich benutze Zenon 7.50 und den Report Builder 2.0 von Microsoft. Ich habe ein Chargenarchiv, dessen Werte ich als Trend im Report anzeigen lassen will. Das Archiv kann über ein oder mehrere Tage Daten aufzeichnen, bis es beendet wird.
Alarme verschwinden in der Alarmmeldeliste
Hallo zusammen, wir haben folgendes Problem, bei dem wir Unterstützung benötigen. Wenn wir die Zenon Runtime nach mehreren Tagen schließen gehen die Alarme seit dem letzten Start der Runtime verloren. Auch pber die historischen Daten sind die Alarme nicht
Invalid Variablen anzeigen
Kann man irgendwie eine Liste/String o.ä. mit Invalid-Variablen zur Anzeige bringen. Gruß This is a migrated post! Originally posted on 16.11.2017 by user wenzm. Please be aware that information can be outdated.
Zenon editor 8.2 install fails, due to SQL Server Rules Check code (-1)
Brand new to Zenon software. The Zenon 8.20 software refuses to install. Its hanging on SQL Server install rules check. I’ve tried Win7 (before I found out Win7 can't run the editor!), and also a brand new Win10 Enterprise vm box with no other softwares
Too many I/O variables declared ERROR
I have around 1,50,000 variables in Straton. out of which 80,000 variables are Global variables. My licence is of unlimited tags but still, I am facing the above-mentioned Error while compiling the Straton Project. Please suggest what could be the problem.
Question newbie straton Msql server 2012
Hello, I just downloaded the evaluation version your straton software, being used with codesys, I find it is even easier to use, I managed in less than 5 minutes to make a communication with a modbus rfid reader without scpecifique library.I would like
zenon driver für OTPP Protokoll - Cars charging station
Hallo, können sie mich informieren ob dieser "Standart" bei Stromladung für E-Autos bei Copadata entwickelt wird ? Danke. This is a migrated post! Originally posted on 20.11.2017 by user Jusufs. Please be aware that information can be outdated.