8.20
Profinet IO configurator is unable to load latest Siemens ET200S GSDML (GSDML-V2.35-Siemens-ET200SP-20200130)
Summary Profinet IO configurator is unable to load latest Siemens ET200S GSDML (GSDML-V2.35-Siemens-ET200SP-20200130) Description Profinet IO configurator is unable to load latest Siemens ET200S GSDML (GSDML-V2.35-Siemens-ET200SP-20200130) ...
Time Filter: Weekdays in the Time Period filter" are displaced to the timezone"
Summary The control should display everything according to ISO 8601 which was not working correctly. Therefore sometimes week numbers were not correct day numbers did not fit to the days name first week of the year was not correct These things are ...
Multi-user client project: It is not possible to create new variables & datatypes in a project created in an earlier zenon version and the OS uses Istanbul timezone
Summary Variable cannot be created in Istanbul time zome under special cicumstances Description Variable cannot be created in Istanbul time zome under special cicumstances Information To use a different timezone when possible. Issue Number: 217912 ...
IEC870_10332: support for private ASDUs
Summary The IEC870_10332 driver has been extended to support private ASDUs for a specific device: ASDU 33 - switchgear position with mapping to zenon values (0 for off, 1 for on, 2 for intermediate and 3 for failure) ASDU 36 - like ASDU 4 with ...
Service grid gateway does not send initial values to web engine after broker and web engine restart
Summary - Description - Issue Number: 217654 Fixed on Date: 20.5.2020 Versions: 8.20 0 BUILD 66111
wrong batch filter when executing a report without screen switching function
Summary - Description - Information no workaround Issue Number: 217164 Fixed on Date: 19.5.2020 Versions: 8.20 0 BUILD 66111
Web Engine Deployment Tool does not update used certificate bundle when changing an existing instance
Summary When the configured Client Certificate Bundle does not exist, a default CCB (first) is selected The "Next" button on the ServiceGrid Connector page is only active, when a CCB is selected (i.e. there are CCBs available) and it is valid (not ...
The sorting of the column Drivers in the variable list in the editor doesn't work anymore
Summary Sorting by driver in variable list doesn't work Description Sorting by driver in variable list doesn't work Issue Number: 216544 Fixed on Date: 12.5.2020 Versions: 8.20 0 BUILD 66111
Trend curves are not displyed in the WebClient with the compatibility mode
Summary Client cannot request historian data from Server below 8.20 Description Client cannot request historian data from Server below 8.20 Issue Number: 215639 Fixed on Date: 28.4.2020 Versions: 8.20 0 BUILD 66111
S7TIA: precompiled file with build >63788 doesn't communicate
Summary S7TIA: precompiled file with build >63788 doesn't comunicate Description S7TIA: precompiled file with build >63788 doesn't comunicate Issue Number: 217647 Fixed on Date: 17.6.2020 Versions: 7.60 0 BUILD 66634 | 8.00 0 BUILD 66598 | 8.10 0 ...
LWORD doens't work between zenon and zenon logic
Summary For integrated projects with drivers which support LWORD (straton32, stratonNG, shared Memory), the workbench allows the usage of LWORD as datatype for variables. Description For integrated projects with drivers which support LWORD ...
OPC UA driver crashes during Runtime reloading
Summary OPC UA driver crashes during Runtime reloading Description OPC UA driver crashes during Runtime reloading Issue Number: 218438 Fixed on Date: 18.6.2020 Versions: 8.00 0 BUILD 66598 | 8.10 0 BUILD 66840 | 8.20 0 BUILD 66627
Extended Trend-> Export displayed data": the ID of the variable is not exported correctly by using language file."
Summary "Export displayed data" function in Extended Trend does not translate variable identification and unit Description "Export displayed data" function in Extended Trend does not translate variable identification and unit Issue Number: 220209 ...
Screen Switch in Web Engine takes very long when multiple scripts/functions are used
Summary A performance improvement was implemented that boosts the central logic unit of screen switches to screens that contain lots of functions and scripts. The performance boost factor depends upon the number of available functions (recursively ...
IEC61850 Server: data inconsistency in reports when timestamp is from variable for t-attribute
Summary When t-attribute of a data object is managed manually in the zenon Logic project, a report may have been generated with the previous timestamp of the value change. Description When t-attribute of a data object is managed manually in the zenon ...
STRATONNG: Diagnosis viewer logs Expanding complex type for symbol 'xxx' failed. CT-type defintion corrupted.""
Summary STRATONNG Driver - If projects containing a lot of structure types some structure variables/arrays are not working (i-bit set). Diagnosis viewer contains an error message "Expanding complex type for symbol 'xxx' failed. CT-type defintion ...
3D example file cannot be read in the zenon 3D Tool 8.10 and 8.20
Summary Finding structure of common string-prefixes sometimes runs into endless recursion Description Finding structure of common string-prefixes sometimes runs into endless recursion Issue Number: 219314 Fixed on Date: 16.6.2020 Versions: 8.10 0 ...
ServiceNode in RT does not search for bundles in the correct path in docker
Summary The system path will be read from the registry now. Description The system path will be read from the registry now. Information Manually copying the created bundle to the "original" directory (C:\ProgramData\COPA-DATA\...) solves the problem. ...
Web Engine - CEL screens is not updated automatically for manual changes for the Service Grid Gateway, when these changes are not linked to an Alarm status
Summary The reason for system CEL events is set correctly in the ServiceGrid Gateway Description The reason for system CEL events is set correctly in the ServiceGrid Gateway Issue Number: 218665 Fixed on Date: 17.6.2020 Versions: 8.20 0 BUILD 66627
Web Engine exception on the compiler when deleted variables are still in use somewhere
Summary ETM curves with deleted variables are not shown in the WebEngine, no exceptions are thrown, when an ETM curve uses a deleted variable (other curves are still shown). In 10.00 a warning message is written to the compiler log. Description ETM ...
SmartObjects: Released properties of symbols are set to default values
Summary After a Smartobject Template update the values of the released properties which were set previously are still kept Description After a Smartobject Template update the values of the released properties which were set previously are still kept ...
Conversion to 8.20: Released properties of signature are not set properly
Summary Value for exported symbol property "Signature required" is lost for Symbols created in 8.10 and earlier Description Value for exported symbol property "Signature required" is lost for Symbols created in 8.10 and earlier Information None Issue ...
Command Processing screen is created multiple times if coming from reference
Summary The fix provided only works for new created references but will not fix the issue with existing references. in this case the reference has to be removed, the smart object template stored, and then the reference needs to be added again. ...
Meaning and Waterfall Chart Wizard not operable with 4k Monitor
Summary Reorganize anchor and dock behaviour for the controls Description Reorganize anchor and dock behaviour for the controls Issue Number: 218026 Fixed on Date: 3.6.2020 Versions: 8.20 0 BUILD 66627
Smart Objects: Releasing a property of a symbol leads to renaming of zLo variables in SO-instances and therefore break of links
Summary at update of a smart object template that has zenon logic variables the name of the variables at the instances are adapted correctly like at creation of an instance and not do not use the original name from the template. this is also true if ...
The OPCUA server does not correctly handle limit texts (conditionname) with unicode characters
Summary The OPCUA server does not correctly handle limit texts (conditionname) with unicode characters Description The OPCUA server does not correctly handle limit texts (conditionname) with unicode characters Issue Number: 93838 Fixed on Date: ...
PROFINET IO Controller in zenon Logic sends value 0x00 instead of configured value in zL workbench for specific output to Keyence SR-1000 barcode scanner
Summary PROFINET IO controller variables with a configured offset of 4 do not work Description PROFINET IO controller variables with a configured offset of 4 do not work Issue Number: 221033 Fixed on Date: 6.7.2020 Versions: 8.00 0 BUILD 67015 | 8.10 ...
Compiler Error: Property GIF animation" leads to error, even when "Available in Web" is disabled. .webx file not created, webengine cannot be deployed."
Summary The property for the GIF animation variable is no longer validated for screens that are not used by the web engine. Description The property for the GIF animation variable is no longer validated for screens that are not used by the web ...
Dynamic position movement of pixels setting to 0 after import
Summary The dynamic values will be calculated correctly . Description The dynamic values will be calculated correctly . Issue Number: 222344 Fixed on Date: 16.7.2020 Versions: 8.00 0 BUILD 67513 | 8.10 0 BUILD 67223 | 8.20 0 BUILD 67231 | 7.60 0 ...
S7TIA: using in the driver the symbols form precompiled file with the TIA 15.1 extention the import of variables doesn't work
Summary using in the driver the symbols form precompiled file with the TIA 15.1 extention the import of variables doesn't work Description using in the driver the symbols form precompiled file with the TIA 15.1 extention the import of variables ...
ALC: option dashed" leads to wrong display of ALC lines in the RT"
Summary fully transparent ALC lines are drawn opaque under special circumstances Description fully transparent ALC lines are drawn opaque under special circumstances Information using transparency 99% Issue Number: 221591 Fixed on Date: 14.7.2020 ...
AccessDNP3_SG: the DNP3 outstation does not re-order value changes based on the timestamp in the event buffer
Summary The AccessDNP3_SG process gateway has been enhanced with an option to configure the event ordering. Either chronologic ordering or ordering in the order of observed occurrence (default) can be configured. The order of occurrence is in ...
Editor crashes when clicking on Show unused symbols" in the General Symbol Library"
Summary The symbols usage will be discovered correctly . Description The symbols usage will be discovered correctly . Issue Number: 221427 Fixed on Date: 10.7.2020 Versions: 8.10 0 BUILD 67223 | 8.20 0 BUILD 67231
IEC850 Driver Configuration wizard: List nodes cannot be expanded or miss information
Summary IEC850 Driver Configuration wizard: List nodes cannot be expanded or miss information Description IEC850 Driver Configuration wizard: List nodes cannot be expanded or miss information Issue Number: 217458 Fixed on Date: 20.7.2020 Versions: ...
MELSECA: When primary server comes back online (dominant) the MELSECA driver on the standby server is not stopped (keeps the TCP connection alive) and the MELSECA driver on primary can no longer connect to the PLC and therefore the variable gets invalid
Summary TCP Connections are not closed on Driver stop Description TCP Connections are not closed on Driver stop Issue Number: 221250 Fixed on Date: 8.7.2020 Versions: 8.10 0 BUILD 67223 | 8.20 0 BUILD 67231
History of changes: Menus- no entries logged if the changes are made via tree - instead of property window
Summary The change entries will be created . Description The change entries will be created . Issue Number: 221300 Fixed on Date: 13.7.2020 Versions: 8.20 0 BUILD 67231
History of changes: Change of a script is logged as 'New' - also log as 'Changed'
Summary Implemented: Action = "Changed", New value = "New"/"Deleted" . Description Implemented: Action = "Changed", New value = "New"/"Deleted" . Issue Number: 221289 Fixed on Date: 9.7.2020 Versions: 8.20 0 BUILD 67231
History of changes: Recipe changes are only logged if you use the prop. window - It doesn't log if you rename via tree-view
Summary The change entries will be created . Description The change entries will be created . Issue Number: 221298 Fixed on Date: 9.7.2020 Versions: 8.20 0 BUILD 67231
History of changes: Interlocking - no entries logged if the changes are made via tree - instead of property window
Summary The change entries will be created . Description The change entries will be created . Issue Number: 221299 Fixed on Date: 9.7.2020 Versions: 8.20 0 BUILD 67231
Buttons contained in symbols from symbol library are always display in black if symbol is used in combined element
Summary Buttons contained in symbols from symbol library are always display in black if symbol is used in combined element Description Buttons contained in symbols from symbol library are always display in black if symbol is used in combined element ...
Next page