Security Vulnerabilities in the CodeMeter User Runtime software versions 7.00 and lower
Summary We were informed by our supplier Wibu-Systems about six severe and critical Security Issues within their product the "CodeMeter User Runtime" software. A new version 7.10a of the CodeMeter User Runtime software is available from Wibu Systems ...
Not possible to set a negative value in combielement to decrement the value of an unsigned variable; wrong input check of editor
Summary Negative set value deltas now also work for unsigned variables . Description Negative set value deltas now also work for unsigned variables . Issue Number: 224690 Fixed on Date: 18.8.2020 Versions: 8.10 0 BUILD 67751 | 8.20 0 BUILD 67700
SNMPNG32 driver crashes when mode gets switched in runtime
Summary SNMPNG32 driver crashes when mode gets switched in runtime Description SNMPNG32 driver crashes when mode gets switched in runtime Issue Number: 224121 Fixed on Date: 13.8.2020 Versions: 8.10 0 BUILD 67751 | 8.20 0 BUILD 67700
Biffi DCM2: Router data cannot be retrieved
Summary - Description - Issue Number: 224021 Fixed on Date: 12.8.2020 Versions: 8.10 0 BUILD 67751 | 8.20 0 BUILD 67700
Service Grid causes endless number of files in folder C:\ProgramData\Microsoft\Crypto\SystemKeys
Summary Deployment: New ServiceGrid Files in Buildupdate from Analyzer 3.30 and 3.40 Description Deployment: New ServiceGrid Files in Buildupdate from Analyzer 3.30 and 3.40 Information Regarding the linked blogentry in comments one can not just ...
The use of copied user groups the usergroups are changed if login on a runtime client
Summary Copied user groups have duplicate IDs causing synchronization issues in network. Description Copied user groups have duplicate IDs causing synchronization issues in network. Information after copy a user Group in the editor export all user ...
Web Engine: symbol linking rule is not applied to nested symbols
Summary Variable and function substitution is now applied recursively in the web engine. Description Variable and function substitution is now applied recursively in the web engine. Information Do not use nested symbols in Web Engine projects. Issue ...
IEC60870-5-103 disturbance file timestamp
Summary Microseconds are misformatted in Comtrade configuration file. Description Microseconds are misformatted in Comtrade configuration file. Information Manually add microseconds in *.cfg file. Issue Number: 223112 Fixed on Date: 27.7.2020 ...
Generic NET Driver: Stopping and Starting the driver using zenon DriverCommand" functions results in "Loading assembly failed""
Summary .Net assembly is not loaded any more after stopping and re-starting driver Description .Net assembly is not loaded any more after stopping and re-starting driver Information In order to get the Driver Extension loaded again by the Generic NET ...
Set value via Ingress Connector - User and computer name not set correctly
Summary Username and computername are now taken from the Service Grid request and handed over to the set variable value mechanism which inserts them into the CEL (if CEL entries for setting values are enabled). Description Username and computername ...
Gantt Chart displayed in future as long as there is chart on Y axis
Summary When an extended trend screen is using archive data and you scroll into the future, all curves - including Gantt - end at the moment the screen was refreshed. Description When an extended trend screen is using archive data and you scroll into ...
Black Text on Black Background in RGM List View by using color palettes
Summary The color settings will be translated correctly . Description The color settings will be translated correctly . Information Use colors, not palettes. But this workaround is for the customer not acceptable, because they work with templates ...
TIA driver Unable to see variable name / address when wrong symbolic address is set
Summary Columns "Database no." and "Datapoint no." are empty in different log messages . Description Columns "Database no." and "Datapoint no." are empty in different log messages . Issue Number: 227039 Fixed on Date: 29.9.2020 Versions: 7.60 0 BUILD ...
Simotion driver uses only less than 240 Byte PDU Size
Summary The Simotion does not use the Optimum Telegram length. It is limited to ~240 Byte. Description The Simotion does not use the Optimum Telegram length. It is limited to ~240 Byte. Issue Number: 226704 Fixed on Date: 28.9.2020 Versions: 7.60 0 ...
SNMP Driver Configuration, Offline MIB list: Column 'Name' shows OIDs instead of translated names from MIB-file
Summary SNMP Driver Configuration, Offline MIB list: Column 'Name' shows OIDs instead of translated names from MIB-file Description SNMP Driver Configuration, Offline MIB list: Column 'Name' shows OIDs instead of translated names from MIB-file ...
Switching to an IMM screen blocks Runtime for 30 secs
Summary Variables that are no longer found in the project will no longer slow down the opening of the IMM screen. Description Variables that are no longer found in the project will no longer slow down the opening of the IMM screen. Issue Number: ...
Process Gateway DNP3 SG: Select fails with status code A_STATUSCODE_ALREADYACTIVE
Summary Process Gateway DNP3 SG: Select fails with status code A_STATUSCODE_ALREADYACTIVE Description Process Gateway DNP3 SG: Select fails with status code A_STATUSCODE_ALREADYACTIVE Issue Number: 227124 Fixed on Date: 24.9.2020 Versions: 8.10 0 ...
Message Control SMTP Encrypted sending type not robust against laggy network connection
Summary When the SYN-ACK is received with a delay higher than 100ms, openSSL reports "connecting failed - no more retries". Added a logical retry loop: in this case wait 1 second and then retry (max 3 attempts) to resolve this. Verified by debugging: ...
Message Control SMTP sending type: Not robust against lagging SMTP connection
Summary The message control engine tried to send the EHLO before the received server greeting was fully received (due to lagging connection - there was just one receive attempt without timeout). Now, the engine uses a 10 second timeout for completely ...
Execution of any zenon function in HTML5 Webclient by manipulating frontend JS code
Summary The security issue that resulted in arbitrary function execution from the WebEngine frontend to the backend is now fixed. Now only functions that are linked to available screen elements are possible to execute. Description The security issue ...
External Reference Entry in Editor is lost after Synchro (Multi-User)
Summary Some screen properties are not saved correctly if check in is done immediately after modification without details view loosing focus in between. Description Some screen properties are not saved correctly if check in is done immediately after ...
zenon6.ini should be created using Unicode encoding format by zenon setup ISO
Summary Changed Default Encoding of zenon6.ini to UTF-16 for 8.10, 8.20, 10.00 Description Changed Default Encoding of zenon6.ini to UTF-16 for 8.10, 8.20, 10.00 Information To save the zenon6.ini file in Unicode format manually in Notepad. Issue ...
IEC870 and SPRECON870 set same internal timestamp for different received telegrams
Summary Maxmimum Resolution of internal timestamps limited to about 10 ms in worst case. Description Maxmimum Resolution of internal timestamps limited to about 10 ms in worst case. Issue Number: 222380 Fixed on Date: 26.8.2020 Versions: 8.10 0 BUILD ...
BeckhNG: Some data points are missing when importing a specific .TPY file
Summary When datatype declaration and usage of that data type doesn't have the same case the type could not be found. Description When datatype declaration and usage of that data type doesn't have the same case the type could not be found. ...
Message Control: E-mail subject does not show correctly Japanese characters
Summary From now on - SMTP mail subjects does support UNICODE . Also zenon6.ini must be saved as UNICODE . Description From now on - SMTP mail subjects does support UNICODE . Also zenon6.ini must be saved as UNICODE . Information Please save your ...
Scaling of symbols in web engine is different from runtime
Summary The offset property of the segment of circle element now get correctly scaled in the web engine. Description The offset property of the segment of circle element now get correctly scaled in the web engine. Issue Number: 226425 Fixed on Date: ...
Runtime crash when executing a SAP function
Summary Runtime crashes on reception of string values via SAP interface Description Runtime crashes on reception of string values via SAP interface Issue Number: 227706 Fixed on Date: 7.10.2020 Versions: 8.20 0 BUILD 68579
IEC60870 104 Slave - Driver does not start on a Linux VM if the application is compiled with an old version of the Editor
Summary -. Description -. Information T5Master870SlSt.h file must be modified: class CT5Master870SlStProps : public CT5BDPropsEx { public: CT5Master870SlStProps() {} virtual ~CT5Master870SlStProps()A_OVERRIDE = default; virtual T5_BOOL Build (T5_WORD ...
Released properties on symbols inside a smart object template do not get updated correctly
Summary Update of the SOT should work correctly also for symbols and released properties in symbols Description Update of the SOT should work correctly also for symbols and released properties in symbols Issue Number: 226418 Fixed on Date: 15.9.2020 ...
Interchanged functionality of CEL comments and AML comments protocolling in CEL properties
Summary Settings for CEL entry on modification of CEL comments and AML comments are interchanged Description Settings for CEL entry on modification of CEL comments and AML comments are interchanged Issue Number: 226727 Fixed on Date: 10.9.2020 ...
Incompatible file creation between x64 and x86 for batch module
Summary An Unique-file hash will be handled as 64-bit dump . Description An Unique-file hash will be handled as 64-bit dump . Issue Number: 225759 Fixed on Date: 1.9.2020 Versions: 8.20 0 BUILD 68579
zenonLogic wrong code creation inside UDFB
Summary The udfb variables were had a zenon variable id linked. So it exchanged the names of the udfb variables with the name of zenon variables. Now it ignores the zenon variables for udfb and creates names as expected. Description The udfb ...
License Only one single process screen": Integration projects start screen disappears after reloading sub project "
Summary with license "Only one single process screen" after reload of a project open screens from other projects aren't restored Description with license "Only one single process screen" after reload of a project open screens from other projects ...
Conversion of a symbol that contains embedded symbols takes minutes with Editor 8.20
Summary Linked symbol converting to an elements group will be processed without the redrawing inside . Description Linked symbol converting to an elements group will be processed without the redrawing inside . Issue Number: 224905 Fixed on Date: ...
STRATONNG driver: Alternate value is overwritten with hardware values
Summary Alternate value is kept in even if a new value is received at the driver from the hardware. Description Alternate value is kept in even if a new value is received at the driver from the hardware. Issue Number: 224160 Fixed on Date: 26.8.2020 ...
Can I use the EUROMAP63 driver in combination with machines that are limited to file and directory naming scheme in the DOS 8.3 format?
Summary I have generation MC4 and MC5 machines that support file naming and directory naming only in the 8.3 naming format. Description I have generation MC4 and MC5 machines that support file naming and directory naming only in the 8.3 naming ...
column for variable for tag value" cannot be configured but still appears in the list"
Summary The column will be presented at the list configuration also in ED . Description The column will be presented at the list configuration also in ED . Issue Number: 182023 Fixed on Date: 22.10.2020 Versions: 8.10 0 BUILD 69252 | 8.20 0 BUILD ...
strange start time of the Runtime with equipment model
Summary Startup of runtime takes a long time if a lot of variables are linked to equipment groups and equipment model is very large. Description Startup of runtime takes a long time if a lot of variables are linked to equipment groups and equipment ...
Runtime freezes while scrolling in IMM List
Summary Runtime freezes while scrolling in IMM maintenance list if maintenance status variables are used and column "Status" is displayed. Description Runtime freezes while scrolling in IMM maintenance list if maintenance status variables are used ...
zenon keeps scrolling in List-Elements(CEL/AML etc.) even if you remove mouse/finger from scroll-arrow
Summary Scroll bars in list controls do not recognise mouse button up event if mouse has moved outside the scroll bar. Description Scroll bars in list controls do not recognise mouse button up event if mouse has moved outside the scroll bar. ...