Recent Topics
More than one alarm in Alarm status Line
Hello, Is it possible to show more than one alarm in Alarm Status Line? I was thinking of showing 2 lines in the alarm status line, so that it will show 2 latest alarms at a time. I've made an image just for an example ;) attached the image here. ---
Events wont Debug in the RT
Hello, I have an issue with the debugging of an event. My code works without error and the event works too when I start the runtime and the event happens. When I start the debug session in the Runtime, the events wont run anymore. When I start the debug
Get Tagname of variables at RT in all available languages
Hello, I am using zenon 7.11 and C# and here is my problem: I have a variable (A) with a Tagname with a Key Text (@AText) . I have 3 language text files (german, english and spanish) in my sql folder of the project (C:\ProgramData\COPA-DATA\SQL2012\GUID
Password Character
Morning all, I may be completely missing the obvious but is it possible to set a dynamic text element (or the string variable it is linked to) so that it will display the characters as hidden, for example "******"? Thanks David This is a migrated post!
Increase value of variables
Hello, I would like to do the next: I have 15 variables (var1...var15) with different values and later I have 2 buttons (but1, but2) to modify all the values according to another variable (var_mod). Not all the time the 15 variables are activated. Depend
Communication and CPU - Power Problems
I did the Connection with WIFI from zenon RT to EV3. If i just use the variable monitor in zenon logic - it works (but also there, every 5 to 10 s there is an interuption of the communication between Controller and PC). When i start up zenon RT and communicate
Missing Motors in FieldbusKonfig of zenon logic for EV3
By adding the EV3 Controller, i did not get the drive ports! This is how the config tree looks like: LEGO EV3 - EV3 - Buttons - Sensoren - Port 0 .. 3 There are no drive ports!!! When i add the NXT Controller, it looks like this: LEGO Mindstorm NXT 2.0
multiuser project check in not possible (SQL error)
We successfully created a multiuser project, that worked fine. But, since I am now at home, conection via VPN to the fab-network, it is not possible for me, to check in the variable module I`m able to check out and in any other module and it is also possible
Multiple copy of variables.
Hello. I need to do a copy in Zenon of many variables based on a trigger, for example If BOOLVAR = 1 Then INT1 = INT2 INT3 = INT4 INT5 = INT6 etc. The only way I can think of doing it is with multiple Allocations, but as there are over 100 copies required
Counter
Hi support team, I need again your help..How can I count the change of value.. I want to count every change of my online variable.. is it posiible? have a nice day.. This is a migrated post! Originally posted on 16.09.2014 by user fatih.oz. Please be
Dual Ethernet Port in Runtime PC
Hi Support, I am using zenon V7.11. I have zenon runtime running in PC with dual ethernet ports. Those ports are connected into the same hub. Everything is running well, but when the primary ethernet cable (primary port) is disconnected, the runtime is
Viewing of COMTRADE files in zenon Analyzer
I understand that the zenon IEC 61850 and IEC 60870 drivers support the retrieval and storage of COMTRADE files. Is it possible to retrieve and store these files in zenon Analyser and if so, is it possible to view these files in zenon Analyser using a
Dropdown Box....
Hi is it possible to chnage the dropdown box so that all entries are visible and not the selection arrows? thanks David This is a migrated post! Originally posted on 15.09.2014 by user synergyautomation. Please be aware that information can be outda
Latest AddOn for the zenon Science Package
Hello everybody, the latest AddOn for the EV3 Science Package is available. This update resolves the following issues: [INDENT]1. Wi-Fi connection problem 2. Problem with the SINT data type 3. Problem with color- and infrared sensor (an old issue is still
S7 Treiber - DiagViewer Error ReadISOFrame ReadPDU
Hallo, bei der Analyse einer DiagViewer Aufzeichung bei einem Kunden ist mir eine Fehlermeldung aufgefallen zu der ich keine Erklärung in der Hilfe gefunden habe. Error ReadISOFrame ReadPDU TCP/IP HW=0 Size=48 Was kann die Ursache für diese Meldung sein?
Style L & Style H for Alarm picture items
Hello support Team. 2 questions on zenon 7.10. 1. Is it possible to use Style values to hide scrollbars of SysListView32 element that shows alarm list on Alarm Message List picture type? 2. Is it possible to use Style values to turn off 3D-style white
Reciepes error
Hello I'm using this code to read every reciepe in zenon project VBA Code: dim zreciepe as reciepe For i = 0 To thisProject.Recipes.Count - 1 Set zreciepe = thisProject.Recipes.Item(i) next It works fine if I run it with Microsoft Visula Basic for Applications.
Folgearchive
Hallo, zenon 7.1 Benötige für eine Durchflussmessung alle angebotenen Folgearchive (Summe, Mittel, Min, Max). Ziel wäre folgendes: Immer um 00:00:01 Uhr sollten in den Folgearchiven der Max-, Min- und Mittelwerte des Vortages abgespeichert werden, sowie
Restore Deleted Project
Hi, Need a favor from you, how can I restore/retrieve project without project backup file? i've accidentally deleted project from workspace without backup, is that possible to restore the project? Urgent, thanks! :) This is a migrated post! Originally
Zenon v7.11 SP0 Build10238 32Bit to 64Bit
Hi, Can I backup project from 32bit Zenon and restore project in 64bit Zenon? Any step needed to change the configuration or settings? Any precaution? Thanks! This is a migrated post! Originally posted on 10.09.2014 by user yitlilee. Please be aware that
User Login : Case Sensitive
Is there any way of making the username case insensitive so that it is always upper case or always lower case, we find if someone leaves caps lock on then we get invalid user. We can't make user names just number. Problem is when we use an RFID tag for
Trends - Adding additional pens in runtime
Hi All, We have a 30,000+ tag system, it is possible to create a new trend or add a new trend pen from runtime without putting all the tags into a function? Cheers, Lee. This is a migrated post! Originally posted on 09.09.2014 by user cccker80. Please
Vba set unit dynamic
Hi Im using the new Unit system, but have a problem regarding dynamically changing unit on a variable. We have a page with a number of input fields that can be changed to show different variables, but if I change the Unit of the shown value, the unit
Bacnet Anbindung
Hallo, ich teste zur Zeit die Anbindung von Bacnet zu Zenon. Wir verwenden als Steuerung eine Saia PCD3. Als Treiber verwende wir den BacNetNG. Die Station wurde hier auch automatisch gefunden und die importierten Einstellungen für den Treiber wurden
Problem Zenon 7.11 Webclient zu 6.51 Server
Guten Tag Wir haben in der Firma Zenon 6.51 auf den Servern laufen und sind gerade am Umstellen auf 7.11. Also habe ich auf den Clients überall schon einmal 7.11 installiert alles funktioniert bis auf ALLE "Schablone schließen" Funktionen. Mit 6.51 Webclient
Execute function Export archive automatically
Hi all, I am trying to export archives using function export archives. I want the function to execute automatically like once daily. also i have to keep time filter at the start fix. and until to be updated daily automatically so that i get a archive
SetMemCfg & milliseconds
Hello support team. In this post http://www.copadata.com/forums/showthread.php?t=2036&highlight=dwTimestamp I found content description of online variable value for shared memory. As I can see, it has not field for milliseconds. So is it impossible to
Archive save .dbf format
Hi support team I have configured an archive. In save option, i selected saving format as database(.dbf). I am getting the database files after defined time interval. Is it possible to get a single file which will append (keep updating) the database.
Get the value of a boolean variable
Hi, For some reason the following method C# Code: this.Variables().Item("intern_rcp_Misplaced Pack Position").get_Value(0)) returns the value -2147483648? However the variable is a boolean so I would expect to see a 0 or 1. I have had this before on other
Message control using USB GSM modem
Hello, After checking the sticky topic Modems that are tested by COPA-DATA for message-control I bought the Huawei E1550 – UMTS-Modem for sending messages. Accordingly the the mentioned topic, it should work, but I think I am doing something wrong.
VBA macros to Macro list renaming in 7.x version
Hello support team. I want to discuss new 7.x version renaming. Can you comment renaming from VBA macros into Macro list in project tree Programming interfaces item? It looks like to new user it will be hard to find where VBA code is located. Additional
Changing a RGMRecipe Items value using VSTA
Hi, The method set_DynamicProperties of the RGMRecipeValue object does not seem to alter the value. I have written the following code; C# Code: public void Macro_editRecipeItem() { String newRecipeName; newRecipeName = this.Variables().Item("rcpNewRecipeName").get_Value(0).ToString();
Scan shows no value + Cant save internvar.bin
Hi We have a strange problem. We have an installation where internvar.bin is not updated when we close zenon. If I delete internvar.bin with zenon running and closes it, it will save all the changes we have made in the new file. At the same time, we are
Message Control - SMS
Hallo zusammen. Gibt es eine Möglichkeit, eine SMS (oder andere Nachricht) auszulösen, wenn ein Alarm/Störmeldung wieder zurückgesetzt wurde (geht-Stempel). Ich habe nur die Möglichkeit entdeckt, dies so zu machen, wie bei einem kommenden Alarm. (Funktion
Message control - SMTP
Hi support team, I am trying to send message through zenon 7.0 to my gmail account. I enabled the pop in my mail settings & did the configurations in zenon. created functions send message and message activate. defined user. Please find the attached snaps.
Screen with changable parametrs in RT
Hello to everyone. I'm in a very beggining level of learning Zenon but previously had an experience working with another scada. Now I faced with some difficulties working with Zenon and for me it's time to ask for your help. The task is following. There
IEC-101 serial Protocol
Dear Support Team, I am trying to configure IEC-101 protocol in zenon7.0. When I try to import the variable, it is showing the message like "General interrogation is running...(2 items recieved)" (Ref: Interrogation.jpg). This process is continuously
Zenon Installation Error
Dear All, I am trying to install Zenon7.00 in Windows XP(SP3). The installation was not completed due to the Error ("Requirements not fulfilled, installation cancelled"). I think this is due to Microsoft Power Shell is not available in the PC. This message
(Ziel-) Variablen eines verknüpften Symbols auslesen
Hallo! Lässt sich innerhalb von VSTA die Verknüpfung auf (Ziel-) Variablen eines Bildelementes (Verknüpftes Symbol) erfahren? Um das Problem genauer zu beschreiben: Ich verwende nur einen Teil eines festen Variabelstamms. Derzeit wird der komplette Stamm
Prüfung auf Vorhandensein von Symbolen
Hallo, zuerst mal ein paar Hintergrundinformationen: ich habe ein VBA-Programm geschrieben, das bei Neuerstellung eines Bildes gleich die Hintergrundgrafik und diverse Symbole einfügt, die in jedem Bild gleich sein sollen. Jetzt würde ich gerne eine Abfrage
Next Page