Recent Topics
CCTV Intergration
Hello, For a new PV project is required by the customer to integrate in zenon energy edition live video streams from a CCTV system. Initially I thought to use ActiveX controls but this technology is currently obsolete. Is there any plugin / driver in
Zenon Energy Edition IEC104 driver Redundancy According Edition 2 LANGROUPS
Hi, I have a question related to redundancy according IEC60870-104 Edition 2. I'm at the moment converting a Sicam 230 program into a Zenon program. The existing configuration with Sicam 230 has following setup: - Two Redundant Sicam 230 SCADA Servers.
ICCP Configurations in Zenon 8.20
Hi, I trying to connect Zenon ICCP Server wit Triangle Microworks Iron ICCP test client. When I try to connect client is gives to me connection error. I tried this case with Triangle Microworks SCADA Data Gateway and Iron was correctly connect to SCADA
Codemeter Fehlermeldung
Lizenz mit 9 Zenon EE Clients V8.10 kann Lizenzausleihe nicht mehr beenden und die Lizenz den HW-Dongel zurückgeben. Bekomme die Fehlermeldung: a previously attached CmContainer is no loger avaibale, Error 70 Was kann ich machen um diesen Fehler zu beheben?
zenon installation fails
Hi Support, My colleague is trying to install zenon V 8.00 but receives the attached errors. He has SQL 2014 already installed on his laptop. Do you think that is the reason, sql cannot be installed? Any solution? Thank you, Shahrzad This is a migrated
61850 driver error
Running v8.0 and IEC61850. Some variables will not load due to was "not loaded because driver with ID '1032' is unknown" This is a migrated post! Originally posted on 29.09.2020 by user Geezerglide. Please be aware that information can be outdated.
Zenon 7.60 combi-element doesn't support png image
Hello. I have problem with combi-element. I have uploaded 2 files to my project. It has png and jpg formats. But when I try to use combi-element I din't see png image. I checked version 7.50 - it works well, but in 7.60 it doesn't work. What is the problem?
Web Client asks requires unlock for command
I am running v8.0 EE. I have two separate systems running the same project. Both systems have redundancy activated. On the remote HMI (Web Client) One system performs normal command dialog using 2 step confirmation. The second system requires unlock before
Create a new variable from a structured datatype in a S7 driver
Hi experts, When creating a new variable and selecting the Siemens driver it filters the datatypes that I can use. It seems that I am unable to use the type STRING inside that structure but other times not even a DWORD. I have started one by one but at
Response variable value Command Processing
Hello. I have an problem i need to change the response variable value that are 0 and 1. I have made an Command group and also a reaction matrix for my signals. The response value is an T31 dubble point information and the command is an TI46 dubbel command.
Experience on Trasformer Monitoring on Zenon
do we have any specific experience on connecting Transformer for its parameter monitoring and reporting? then kindly share some document or sample screens. Thank you in advance. This is a migrated post! Originally posted on 22.09.2020 by user Amit Bharadva.
Regular issue with VBA progress bar and RTFunction end sync
I have a problem with this type of code ' Close a image with progress bar ' I don't understand why exports don't keep up with my variable growth export status percentage How can I write code to increase the percentage variable at the end of each finished
Register OCX libraries from (Win7 - Zenon 6.51) to (Win 10 - Zenon 7.6)
Hi all, I have an application developed in Zenon 6.51 which I need to update it to Zenon 7.6 There is no issues with the Zenon update except a VBA issue with the progressBar but once I sort it out other ActiveX might also have similar problems After registering
Process Gateway - VBA
Hi all guys, it's me again. I'm struggling with the process gateway: IEC870-104. For now I am making sure that when I import the variables into the editor, via VBA, I also write the process gateway configuration xml file. I wanted to ask you if it was
CanOpen Pdo mapping Via Straton
Hi is there a simple way to set the pdo mapping of some slave via straton This is a migrated post! Originally posted on 16.09.2020 by user mos89. Please be aware that information can be outdated.
Return to Last
How to get to the list of previously opened screens? This is a migrated post! Originally posted on 11.09.2020 by user SKR. Please be aware that information can be outdated.
Historian and report generator
Hi. I want to create a archive which will save value of variables once per day at specific time e.g. at 2 pm. I have archive, but It only safe at 12am. I tried to change some settings like 'Start of Archiving', but it didnt help. This is a migrated post!
Pmi526 hmi issue
I got this message error. Error: File 'template.cmp' has version number 5.50 sp7. But project has version number 5.21 sp2. Please help. How can i transfer project Between two PMI526 HMI. This is a migrated post! Originally posted on 12.09.2020 by user
Symbol corrupted
Hi, during working around a Combi_SWITCH_01 symbol in screen, after a modification that, sincerly speaking, I do not remember, the symbol has become without circle and with a blue cross inside the square and it is disappeared from the General Symbol Library.
RDL file - archive
Hi, I need to read variable value from archive in report viewer, but everytime i start runtime and open report the value is 0 (it doesn't read current value stored in archive). How to solve this? I made report in microsoft report builder. This is a migrated
CEL does not arrange event follow timestamp automatically
Hi Engineers I'm configuring Zenon for a substation and face a problem related to CEL (Chronological Event List): If an IED send an event to Server a signal which have timestamp older than the last event was showed on CEL screen: new event should appear
Importing variables and Client IED name in IEC850 driver configuration wizard
Hello everybody, It's my first time using IEC850 driver configuration wizard (I usually configure it with online IED's) so I have a couple of questions about it: 1. I can't see any variable in the list so I can't import them. Maybe, I should import variables
Screen zoom - problem
Hi, I'm new on zenon. I have a screen bigger than the frame, because i need to zoom it. My problem is that when in runtime I open the screen, it opens zoomed in. Is it possible to make it open not zoomed in? Thanks, ER This is a migrated post! Originally
Projekt mit zwei unterschiedlichen Monitorauflösungen
Hallo, ich muss in einem Projekt dieselben Bilder auf zwei Monitoren mit unterschiedlichen Auflösungen anzeigen. Kann ich das irgendwie bewerkstelligen ohne die Bilder 2mal erstellen zu müssen? Danke This is a migrated post! Originally posted on 02.09.2020
Zoom Respone Image
Hi, again :D What is the easiest and fastest way to show a symbol, but at a certain screen zoom level, change the symbol? I had thought about using the combined element, but I don't know how to set a variable related to screen zoom Many thanks in advance
Trend Relative Time
Hello, In extended trend in screen switch I have relative time filter to 1 second as shown in Image-01. In Runtime it shows as 11 seconds as shown in attached Image-02 I had checked by setting 5seconds in that case it considered as 16 seconds. So is there
Downgrade form 7.60 to 7.20
We have working application under 7.60. Customer is requesting to have 7.20 with functionality of TIA portal driver. How to convert our application to 7.20 This is a migrated post! Originally posted on 26.08.2020 by user SKR. Please be aware that information
Disable Alarm Functions at Nighttime
Hi, We have multiple alarms with limit values and reaction matrix from different variables. And using some functions/scripts in the cases if the limit values are violated. Like sending e-mail messages and playing alarm sounds. I want to disable these
Extended Trend - Disable dragging / moving of Scale
Hi, is was not able to find an option to lock the position of Y- and X-scale in a diagram of type extended trend. We want to prevent the user from moving the scale of X and Y axis by mouse/touch control. How can this be achieved? Thanks. BR Eric This
Message Control - SMTP Gmail does not work
Hello, We are trying to configure the Message Control service in Zenon to send alerts. We are using Zenon 8.0 SP0 in demo mode. We have created a Gmail email address and configured Message Control with the following settings (see screenshot 1). Checking
Straton IEC 60870 104 Slave Timestamp
Hi All, I have problem with Straton Version 8.6 ( find attached version screenshot ) with IEC 60870 104 timestamp information. I didn't find it in the IDE of straton, can you please tell me where i can find this information, is very urgent to be able
Report Generator - the last few values of archive.
Hello, I would like to do some calculation in Report Generator based on archive values. Calculations are based on increase of the value over some time, so I want to use two last values from aggregated archive. Problem is, that when I used function archivesp(2,"value","bottom",1,0,0)
importing multiple recipes
Is there a way to import more than one recipe at a time ie from the chooser to select a bunch of the recipes and import instead of one at a time which is tedious and takes a long time if you have more than one or two recipes. This is a migrated post!
GOOSE publisher via zenon Logic
Dear support team I use zenon 7.10 for my diploma dissertation. I need to create SCADA for medium voltage system model, where I use 2 control relays (ABB REF615) as my IEC61850 IEDs. I want to control these relays (to open and close circuit breakers)
Can I use excel to read the file created by F_SAVERETAIN function?
I used F_SAVERETAIN function to save it to this path 'C:\Data\RetainVariables'. I got the file but could not open and see it in Excel. What kind of format of that file? This is a migrated post! Originally posted on 12.08.2020 by user huywartsila. Please
VBA auslagern nach VSTA
Hallo, Es gibt ja im VBA Editor das thisProject. Ich möchte gerne Teile des VBA Codes mit C# umsetzen. Weil VBA läuft im Kontext vom Zenon Hauptthread und kann diesen (bei Timeouts o. ä.) blockieren. Wie mache ich das? Muss ich dafür ein spezielles Projekt
OPC DA Disconnecting
Hey Guys I am facing an Issue with OPC DA driver. When I connect to the OPC-DA server, I am able to connect and the Data flow can be seen. But after 30-60 secs the status of all the variables are turning to "INVALID". When I restart Zenon status is "SPONT"
Function and scripts
I have a pop up Image with some pushbottoms, eachone writes a different number in the same variable A; now i need more pushbottoms (to write more numbers) so i copy the pop up with all pushbottoms changing their functions and scripts (just the value written).
RDA Variables to Configure as REAL Datatype
Hello, In one of project of ours we configured array as a DINT. Configured Timestamp in "Array[5]" as shown in attached image. But If we consider datatype of array as a REAL, how can we configure timestamp? Will you please suggest example of it. Regards,
Application SysSrvCE. EXE encountered a serious error
Hi Friends My computer is using the software Sicam 230 V 6.22 SP1 and runs in Window Embedded CE 6.0. When I launch this software, it appears that the error: "Application SysSrvCE. EXE encountered a serious error and must shut down" I did restart the