Kann VBA Koordinaten über das Touchpanel erfassen
Hallo an alle, Ich habe letztens in einem VBA Code gesehen das man über Koordinaten Bilder verschieben kann. Meine Frage ist es für Zenon auch möglich mit VBA eine Comobox oder Listbox mir an der Stelle anzuzeigen, wo ich am Touchpanel hintippe??? Damit
Windows Event Viewer Log as Alarm Bit In Zenon
Hi all, I am using Zenon Supervisor 7.60 version. There is a situation when mains power fails the PC operates on UPS supply and there is an event generated in windows event viewer. [FONT=Arial]This is regarding Reading Windows event logger. When we connect
Process gateway_iccp_configuration
Hi All, Process gateway ICCP below details were not updated in help, Can anyone clarify 1. General tab-->Server -> VMD specific, Domain Specific 2. Server Variables-->Available for ICCP-->Object type-->Device object I cannot able to get a proper documentation
Logging in the AddIn Framework
Is there a preferred method or toolset for logging when using AddIns. I am using C# with visual studio and very primitive logging ie writes to a file. Im wondering if anyone uses log4net nlog or even windows event log if anything. This is a migrated post!
Problem with VBA progress bar and RTFunction end sync
Hi guys I have a problem with this type of code Public Sub ExportAllArchive() Dim VarPercentage As Variable Set VarPercentage = thisProject.Variables.Item("VarAuxPercentage") ' VarAuxPercentage is linked to a numeric and is rapresented graphically during
Problem with VBA and RTFunction
Hi guys I have a problem with this type of code Public Sub ExportAllArchive() Dim VarPercentage As Variable Set VarPercentage = thisProject.Variables.Item("VarAuxPercentage") ' VarAuxPercentage is linked to a numeric and is rapresented graphically during
Time based recording
Hi all i have created one archive and the start and stop type is based on User Defined via Script and recording type is based on *Event triggering* For Event triggering purpose i have created a zenon logic using blink and the time defined in blink function
VSTA VB.Net not working when start from Startup tool
Dear Team, In one of our IPC VSTA(VB.Net) is not working whenever we are starting the runtime from Startup tool or Runtime short cut(not working in both 32 bit and 64 bit) But, If we start the runtime from Zenon editor VSTA is working perfectly. I would
Message control-SMTP message error
Hi, I tried to configure a gmail account in Zenon message control but could not send any message. Copadata tech support was able to send the message with my email address and also tried the sample backup provided by techsupport. I tried in two different
Additional Data Folder Created with remote pc name while running zenon From remote PC
Dear Sir, I am using Zenon Supervisor 7.60 Build 56718 while i take my IPC remote with remote desktop and run the zenon from remote pc it is creating new data folder with remote pc name so i am having 2 data folder one from my IPC name and another from
Need to provide the Engineer in Vietnam
We have demand to find the engineer for our configuration of Zenon Energy Edition in Vietnam. If anyone can provide the engineering fee, pls contact with me - Some document for the reference This is a migrated post! Originally posted on 13.09.2019 by
Hysteresis on Historian Archive
Hello Everyone, I have a question! My IEDs send to Zenon 8.00 some cyclic measurement (2s) from field and I use this data for trend graphs. To preserve data storage and archive of server (10 years average life of the plant), I would like to save the data
Archive Importieren via SQL Treiber
Hallo zusammen, ich habe archivierte Daten die ich gerne in zenon importieren würde, um dort mit Erweitertem Trend und Reporting zu arbeiten. Wichtig sind hier die in der Tabelle der Ausgangsdaten vorliegenden Zeitstempel, die dürfen nicht verloren gehen.
MODRTU32 symbolic address
Dear COPA DATA forum members, To sum up the story, I am using MODRtu32 driver, and what I have seen symbolic address is like in IEC - 61850 (please see attachment). Can somenone explain me if MODRTU32 uses symblic address for reading variables ststuse
Cyclic driver information
Hello, Update time for IEC61850 driver is set 100ms by default it cannot be change. In zenon help file i have found information regarding cyclical driver. Help file Screenshot attached. Can you please tell me list of the cyclical driver in zenon. How
Getting and Setting Values in Standard Recipes
What would be the best way to get/set values in the Standard Recipes? I have a Standard Recipe Collection which includes pipe "Size" and "Schedule" entries and if these match my target values, I want to set a "Selected" value as true. Please see the draft
Zenon 7.5 how to connect to TIA15
Can anyone provide some direction on how to connect to TIA15 Simatic s7-1500 with Zenon 7.5 build 55804 64Bit? We are not having any luck with the S7-Driver for S7-1200/1500 driver. Is there another driver we should be using? This is a migrated post!
Zenon6.INI file corruption
Hi, The configured Zenon6.ini file is corrupting or going to default configuration at the time of unexpected shutdown of PC. Please give me a solution. Thanks. This is a migrated post! Originally posted on 06.09.2019 by user Kameshwaran_Subburaj. Please
WPF elements in HTML5
Hello, I would like to know, if WPF elements, like gauges, bars etc., are supported by HTML5. Thank you in advance for your answer. This is a migrated post! Originally posted on 20.09.2019 by user grzegorz_kaczmarczyk. Please be aware that information
Zenon parameter inVBA script
How can I assing values to a parameter from a VBA funtion from a Zenon Element? I want to use a Funtion with 2 parameters when the user click in a Funttion. I This is a migrated post! Originally posted on 05.09.2019 by user q1883. Please be aware that
Convert phase to neutral value to be displayed as a 3 phase value
Hi, I have been looking at how to take a received 61850 single phase voltage value which is all the BCU that the contractor has provided and need to display on the over view the 3 phase value for the engineer. In the past substation the BCU's have always
Zenon Time Sync
Hi Guys Is there a way to sync the Time between 2 systems using Zenon? Consider I am having Zenon running on both the systems, is there any driver or procedure to configure in zenon to Sync the Time from System 1 to System 2? Also I need to sync the PLC
Licensing tool failure
Hi everyone Does anyone know what is the reason that "Licensing Tools" doesn't load? Actually i haven not any access to licensing environment, so i can just use the demo version! Although i uninstalled and reinstalled zenon version 8.00 again, still the
How to open 7.60 workspace in 8.10 editor?
Hello everyone, I'd like to ask what is the proper way to migrate the whole workspace of projects from zenon 7.60 to 8.10? Currently I have both Editor's versions installed on my machine (7.60 and 8.10), I have also prepared workspace backup in 7.60.
Reportfunktionen ( Subtrahieren)
Hallo Zusammen, gibt es ein Trick oder eine Funktion um eine Substarhieren in report zu bilden? Ich finde keine Fuktion , die die Substrahierung zwei Werte macht. Gruß Alex This is a migrated post! Originally posted on 02.09.2019 by user Alex Takam. Please
Variable Change Event vb.net Visual Studio 2015
Hallo, Ich realisiere gerade eine WebSocket Schnittstelle als ProjectServiceExtension mit dem Zenon AddIn für Visual Studio. Ich muss bei einer Wertänderung einer Statusvariable einen Befehl Richtung WebSocket Server schicken. Wie kann ich ein Variable
Pointers in Zenon
Is it possible to make indirect addressing (pointers) to PLC variables? I would like to use an internal or PLC variable which contains the address of the variable value I need to access. I cannot use the substitution functionality because I do not want
Standard recipe not exporting when configured as a Network
Hello. I am sorry if this is very basic, but I have never used recipes before. I have a standard recipe which copies variable values to a .txt for comparisons purposes. The recipe is read and exported from functions on the screen and creates a .txt in
Control IEC61850 function block
Hi sir I want to control SPC variable within zenon logic. I will use IEC61850_WRITE function. it explain that PATH STRING Path to data point (without "ServerName!") IF I set path = Bay431!BAY431System/PloGGIO1/SPCSO1/Oper.ctlVal[CO], your program said
Variable between Macro and zenon
How can I give a value for a zenon's Variable in a Macro This is a migrated post! Originally posted on 22.08.2019 by user Omarzubair. Please be aware that information can be outdated.
Zenon crashes while reloading
Hi," when ever I reload the project after editing the project its not freezing with 'Please wait-in progress" window. I tried un-reinstalling the software but no luck due to this I am not able to work on the project. Attached the log file Version 8.00
Excel report
Hi, I have used Report viewer to get the OEE data with down time reasons with three tables and report is generating as per the requirement and only issue is while exporting this report to excel most of the columns in excel is getting merged. This is very
not able to select/find database of sql
Hi, I am having a query of creating historian reports that while creating reports in the sql database ,data link properties i am not able to select/getting data base on the server, even though my server name is correct. This is a migrated post! Originally
Zenon editor crashes
Hi, My zenon editor always crashing while creating changed runtime files. Attached a snapshop also the version details are mentioned below Zenon version-Version 8.00 SP0 Build46644 32Bit Sandy This is a migrated post! Originally posted on 20.08.2019 by
Subtraction of current variable value and value of the same variable from one hour ago.
Hi, I would like to display in Numeric Value the subtraction of current variable value and the value of the same variable from one hour ago. The result will change every 10 minutes. The variable is archived in 1 second cycle time. How to implement such
Menu Bar in main project
Hi, I have used the run time menus function to navigate through the integration projects. Is it possible to customize this menu window size and all as it is appearing in very small font in runtime system. The purpose is to navigate through the sub projects
zenon 6.20 project convert to 6.22 Version
create runtime ,show :project.mdb file will be not overwritten, password.cmp file will not be overwritten This is a migrated post! Originally posted on 19.08.2019 by user ludongyuan. Please be aware that information can be outdated.
Polygon as Button or polygon shaped button.
Does anyone have an idea on how to execute a function when clicking on a polygon, or how to create a polygon shaped button? We do a lot of screen switching from floor plans and now I just put transparant buttons on top of the polygons that represent a
Cel values datag storage feedback
Hi , I have this unique request from my client where as he wants to have a feedback if possible that Cel and Aml data is being saved in the hard disk. Basically he wants to know if possible that historian data should be saved or record every time when
Can't install Zenon 8.10
Hi, do you can help me? I can't install zenon 8.10. screen - https://prnt.sc/os23zn button for install "zenon Editor" is disabled. In begin I was need to change my zenon version 7.60 to 8.10, but when I install zenon 8.10, it don't work. Don't work Demo