"smart object" using .vba macros
Hello, in the smart object tab I cannot edit macros as it is possible in the main project. The VBA macros tool seems to be available but no way, to import or edit it, is available. Please inform me about the way I can edit vba code in the "smart objects".
Reaktionsmatrix mit Excel (o.ä.) editieren
Hallo, ist es möglich eine Reaktionsmatrix außerhalb von zenon zu editieren? Vom Editor wird die rema.bin-Datei erzeugt. Diese möchte ich mit einem anderen Programm öffnen, editieren und auch wieder speichern. Geht das irgendwie? This is a migrated post!
60870-104
How setting 60870-104 protocol command. Command signal is dauble bit. This is a migrated post! Originally posted on 18.08.2021 by user battsooja. Please be aware that information can be outdated.
How to create enumerated data type in zLogic?
I would like to create enumerated data type like NAME INT PHASE_IDLE 0 PHASE_START 1 PHASE_IN_PROG 2 PHASE_STOP 3 But I'm not sure how to do that? This is a migrated post! Originally posted on 17.08.2021 by user milosh. Please be aware that information
Variable substitution fro context menu?
Hi all. I have one context menu with varibale set value 1 - PAR_varname 2 - PAR_varname 3 - PAR_varname Screen with parameter substitution on different button click where params can be E1, E2, T1... But it does not set the values... Does parameter substitution
Read database files on different computer
Hello, I want to pick up all database files from Zenon 8.10 machine (alarms, events, historian data...) and read them on another Zenon machine. What is the best way for this operation? Any suggestion? Best regards This is a migrated post! Originally posted
Maintenance_SO_CD_Diagnostics_XXX screens not editable?!
Hi all... I use Pharma HMI demo application set, but when I try to modify Screens with name Maintenance_SO_CD_Diagnostics_XXX it can't be done. All these screens are "read-only", no possibility to insert elements etc. How to unlock these screens for editing?
PID in zLogic?
Hi all... I would like to know, did someone use PID control in zenon logic? What is th menaning of DEADBAND_Error parameter? Here is Deadband in relation with PV an previous PV... (PVPrev-DB < PV < PVprev+DB) error stays the same as in prev. cycle? What
Bilder direkt aus dem Explorer laden und anzeigen
Hallo, Ich würde gerne mit einem SPS Signal auf einem Bild direkt eine Grafik anzeigen lassen. Mit welchen Zenon Mitteln wäre das am besten um zu setzen? Hat jemand von Euch so etwas schon mal gemacht? Vielleicht habt Ihr ja für mich ein paar Tipps. Vielen
Scada - plc reconnection
Hello All, I am using a SIEMENS S7 TCP-IP DRIVER to communicate with S7-1200 PLC (ZENON SUPERVISOR) . I am having 3 S7-1200 PLC. PLC1 has 424 tags, PLC2 has 381 tags and PLC3 has 2333 tags. I am facing an issue with the SCADA - PLC Communication Reconnection
? disable/unistall editor and keep runtime
Hi, here on our servers, zenon editor 7.60 and zenon runtime 7.60 are installed. Now I would like to disable/uninstall the editor, but keep the runtime. I would like to do this, because the SQL server sometimes produces a lot of CPU load, such that the
Can't run "subproject VBA function" from integration project.
Hello. I have integration project with 6 subprojects. One of the task is to running some subproject VBA functions from integration project main screen. For example, I use the code like this: ApplicationED.Projects.Item("SUBPROJECT_NAME").RtFunctions.Item("SUBPROJECT_FUNCTION_NAME").Start
Analyzer OEE Template Report
Hello All. Does anybody know if there is a step by step on how to use the OEE Template in Analyzer? I have been trying to use the Help, but this report seems to be tricky. This is a migrated post! Originally posted on 22.07.2021 by user ronei_candido.
I need to predefine which variable to display in the report in runtime
In my recent project I am facing some issue, Previously I am displaying a set of 50 variables in the report, I am using report builder and report viewer , now the new requirement is the customer need to select the particular variable out of the 50 variable
Filtern nach Variablen
Hallo, wir haben ein Projekt mit sehr vielen Variablen (200000+). Hier sollen zur Laufzeit einzelne Variablen mit einer bestimmten Endung in einem Addin gefiltert werden. Aktuell setzen wir dies mit einer For-Schleife um. Das benötigt sehr viel Zeit bis
rweiterter Trend Diagramm X-Y Darstellung ?.
Hello, Ich würde gerne ein Diagramm anlegen mit einer x-y Darstellung. Hierzu habe ich ein Bild erstellt mit dem Typ erweiterter Trend. Dazu dann die Bildumschaltungsfunktion, bei der ich dann auch in die Parameter eingabe komme, soweit funktioniert noch
Datentyp zuweisen
Moin, ich habe noch ein weiteres Problem. Ich weise im Zenon Editor über ein Addin, Variablen bestimmte Datentypen zu. Dies mache ich wie folgt: variable.SetDynamicProperty("ID_DataTyp", BeispielDatentyp.Id) Das funktioniert soweit auch gut und
Read group of tags "on demand"
Hello everybody, I'm trying to read around 250 tags of different types (boolen, int, string, decimal... ) for 10 different PLCs. This values only need to read it when each PLC send a boolean signal. However, it are too much tags to keep it "advice" all
ReImport Old CEL values
Hello everyone, Is it possible to reimport previously exported CEL files (CSV, SQL or XML) and analyze them in Zenon again? I didn't find any option for import files related to CEL. Thanks in advance! This is a migrated post! Originally posted on 14.07.2021
Export Wizard for zenon Analyzer 3.40
Hi All. I have been doing the Analyzer training and there is a step to use "export wizard analyzer", but I could not find any export wizard analyzer in zenon "Tools > Start Editor Wizards". Is this step not necessary for the versions I'm using it? zenon
AML and CEL exporting header
Hi, I'm working on a ZEE project that has AML and CEL implemented. I'm working on an export function and it works fine, I get the data that I want exported, but the .CSV file lacks a header line to it. Is there a way to export column names to the first
Remanent variable value changed to 0 or 1 in RT for Zenon Internal variable's automatically
Hello Team, I used Zenon internal tag (String data type) as a remanent tag and in this randomly the tag value was changed to either 0 or 1 without any manual intervention. So whatever the string value i have entered in internal variable was changed. This
Min and max set value from another varibale?
Hi all. I made two buttons, 1st button INC, increments variable value named INDEX by 1. Also there is DEC button which decrements INDEX by -1. I would like to dynamicaly change max set value limit for Index variable. Sample. Max set value should be limited
network configuration
HI COPA-DATA team I have question's about Zenon network connection, for example, if we have two pc in the same network based on DCOM, we installed in pc one OPC server (we use codesys OPC and name pc1) then in another pc (pc 2) we have Zenon, now my first
MODRTU32 Connection status
Hi all. I have app which communicate with 9 MODRTU32 devices. Variable STRING type with offset 61, and dynamic text element. Text appears like: 1:0;2:1;...9:0; From documentation format is: :;... Connection status: 0 - ok 1- failed 2 - simulated How to
VBA Complie error Invalid data format
Hello, I have this error when i lauch client zenon I haven't got the probleme the server, with the develloper and runtime application. the module structure is empty on the client The files vba are update when i launch the runtime This is a migrated post!
Write calculated variable to the PLC
Hello, I am wondering about limitation of managing variables. Simple task is to write calculated variable to the PLC. For example I want to make sum of two variables and write result to PLC variable. Any suggestions? Best regards This is a migrated post!
Modifying bit in Word
Hello! Sorry for my bad English, but I hope you will get me! Can I write/modify a bit in a whole Word variable with a Button, Combined Element or anything else? As you know, a Word variable got 16 bit (so every bit can be 0 or 1). So I would like to modify
Can i do this with RGM
Hi, I need to develop a system to test water meter accuracy where i have the following data need to be recorded & updated. Below are the scenario :- list of data :- a. serial no - String b. initial reading - Float c. final reading - Float d. temperature
How conect opc ua server for runtime zenon 8,20
Hi all we have a zenon runtime 7.10 we need get some vars from this runtime , what its the best way to get this vars, its possible get this vars for opc ua client for this job, thank a lot for your time . Ris automation This is a migrated post! Originally
Write variable from background worker
Dear Forum users! I am looking for help with the following problem. I have an application in which I have a background worker in the C# VSTA environment. In this background worker, I repeatedly report progress, which calls the ProgressChanged function
Write values to the variable on demand
Hello, I have one field to enter the numeric value of the internal integer variable. When I press the button, I want this value to be written to another PLC variable. Any recommendation how to do this? Best regards This is a migrated post! Originally
AML/CEL Message with exception
Hi, a customer gets this message when he hits the button Filter... in the screentype alarmlist: Exception in Wnd=0x028A01F0(ALARMLISTE) processing message 0x0111 IParam=0x00000000 wParam=0x00002721 Someone here with experience with this problem? Is it
Two Alarm Objects with different amount of lines
Hi ! I wanna have two alarm objects with different amount of lines: 1. An Alarm object in the main screen (main frame) 2. An alarm object in the top of the screen (in a different frame on the top) showing the 2 most recent alarms. I have tried the Alarm
Show alarm value with different text
Dear All, I need to show the status of the variable or it value with different txt, like I want to show the value not numbers (0/1) I need to make (ALARM/NORMAL)(FAULTY/NORMAL)…..etc. When I use the txt at reaction matrix only one value coming at the
Access violation OPCUA32
What is the reason for the following error in file OPCUA32.txt? It happens at the closing the runtime zenOn Version: 8.20 SP0 Build80611 Processor: x86 //----------------------------------------------------- Exception code: C0000005 ACCESS_VIOLATION Fault
Command processinng zenon edittion
Dear support team. Good working day to all of you. I just started learn about Zenon edition 8.2 32bit with a simple project. In my project, I create a standard screen named "overview" for single line Diagram. In which i Created a combined element object
Communication error
Dear sir, I have zenon 5.2 with cp5611, desktop system. I found hardware okay SG/pg utility but it is not linked with zenon 5.2 kindly help me to resolve. Os win 2000 prof. This is a migrated post! Originally posted on 18.06.2021 by user rajanpurnanand.
ZENON / B&R HMI -Help
Highest Rated Power Washers Nowadays pressure washers are very popular, and have become an indispensable household item. Not only professional services need this machine to make their work easier, but also, each family wants to equip themselves with one
ImportFromCsv Function on IVariableCollection
Hi, I'm attempting to import a batch of variables in Zenon project via the AddIn API in C#. Within the IVariableCollection the "ImportFromXml" function is available, but I cannot find the import function that works with the tab delimited "CSV" files that