MITSUBISHI internal relay
Hi, I have problem with Mitsubishi internal relay M (Adress MIT), for example M65 or M100, adress on Mitsu. is Hex on Zenon is Dec, 65H->101D, 100H->256D and which is the value on Zenon adress offset or bit? I havenÂ't problem input(X) or output(Y). I
Metric / English Unit Conversion HMI
In the PLC all calculations are done in metric units and at the HMI the user will have the option of Metric or English units. This means that if English is selected the raw value from the PLC must be multiplied by 1/25.4 before being displayed on the
Can't repeat WPF#1 blog examlpe
V6.51SP5 On the last stage (PassDataDirect VBA function) I give error before use of obElement.WPFProperty. Public Sub PassDataDirect() On Error GoTo Exit_Proc MsgBox thisProject.DynPictures.Item("Screen 0").Elements.Item("WPF").Top Dim obElement As Element
VBA Wizard Zuordnungen
Hallo ist es möglich Zuordnungen(Assign) die in einer XML.Daatei gespeichert wurden über einen Wizard in ein anderes Projekt zu importieren Und wenn wie heißt der Befehl Ich verwende Zenon 6.22B17 Grüße This is a migrated post! Originally posted on 14.07.2011
Save Alternate Value?
Hi to all In Runtime I Have to Switch to alternate value and Modify alternate value. But when reload the Runtime variable Switch to spontaneous value. How can I save alternate value after reload the Runtime? This is a migrated post! Originally posted
More efficient way of doing thing
Hi, i am thinking of a more efficient way of doing this. Maybe you can lend me a hand in this. I have this scenario. When i try to disconnect my notebook from my network. I noticed my SNMP-Variable becomes unavailable and i get a small red dot on the
Coloring Entries in Object List of WorldView Navigation
Hi Support, We can define text in the property 'Name for Object List' in order for it to appear in the "Object List" for World View Navigation purpose. Assuming I have more than 1 Entry in the Object List, can I assign different colors to them and make
Alignment of Column Headings in CEL and AML
Hi Support, The column headings and their corresponding entries in CEL and AML are aligned left (by default). How can I align them in the centre? Thanks in advance. This is a migrated post! Originally posted on 13.07.2011 by user shikra. Please be aware
Charting in Zenon
Hi, the standard Chart - Control in the Modul "Erweiterter Trend" is not realy nice to view / navigate and it is really hard to make a good overview about a pool of data. Is there new functionality planed in the upcoming Versions? Is it possible to use
Auto Logoff
Hello, How to make the HMI go back to the first screen (login screen) automatically after a certain time, i mean automatic log out function. i have logine screen as a start screen , and after log in i have main screen, heading screen and bar button screen
Many questions about IEC 60870-104
Hi there. I need some informations about IEC 60870-104 protocol. 1. In order information I see that driver is SLAVE(IEC 60870 Slave ZGW-IEC60870SL), but I need the MASTER. Is there a MASTER IEC60870? 2. We use substitute of circuit breaker, disconnector
Calculating average and standard deviation on batch
Hello, For a customer we need to be able to execute the following function for every batch : CPK = (UpperToleranceLimit - Average(Values))/(3*Standard Deviation(Values)) We need to do this for several values withing a batchbased archive. Is this possible
A few queries that need your help
Hi, There are a few things that i need your help :) 1) I was trying to create a min/max function in a frame/Screen but in the detailed properties the min/max check box was disabled. How to enable it? 2) I read the online help, searched the forum but was
Question about license
My project have more than 34000 variables, but my license is XXXXXXX.XXXXX.X.-1024(support 16384 variables). I feel this license can not be used in my project. But the actual situation is this license working very well in my project. I do not know why.
Opening Help
Hi, How come i was unable to open help (*.chm) using the Function->Application->Open Help and call it using a button? When i clicked the button, no response from the button, help file was not opened. Warmest Regards Whitetaru This is a migrated post!
Home URL setting for HTML
Hi, May i know where do i set the home page URL for html browser ? Warmest Regards Whitetaru This is a migrated post! Originally posted on 06.07.2011 by user whitetaru. Please be aware that information can be outdated.
Main Menu VS Context Menu
Hi, I created a button that, linked it to a function (show menu->myMenu*) but during runtime it just wouldn't show the main menu. * my Menu is my newly defined Main Menu. If i use context menu, i was able to right click and display my customized Context
Deleting all entries from AML and CEL
Hi Support, I am using Zenon Energy Edition 6.51. There are two files for the storage of Alarms and Events in the ringbuffer, namely cel.bin and aml.bin. When I delete both the files to remove all the old alarms and events from the ringbuffer, only the
Time Stamp Issue in Alarms and Events List
Hi Support, I have defined Events and Alarms on the 61850 Boolean Variables in Zenon Energy Edition 6.51. The time that is shown in 'time received' column of AML and CEL is advanced by 3 hours for some devices and 10 hours for some other 61850 devices
ZENON EE IN WINDOWS XP embeded
Is there any limitations for Zenon EE running in Windows XP embedded compare to Windows XP professional? This is a migrated post! Originally posted on 04.07.2011 by user rolindo. Please be aware that information can be outdated.
ZENON EE IN WINDOWS XP embeded
Is there any limitations for Zenon EE running in Windows XP embedded compare to Windows XP professional? This is a migrated post! Originally posted on 04.07.2011 by user rolindo. Please be aware that information can be outdated.
Nach welchen Kriterien werden OnlineVariablen angelegt?
Hallo, in einem Projekt muss ich auf mehrere Variablen mit VBA zugreifen. Dafür habe ich ein Container mit OnlineVariablen erstellt. œber ein "Filter" lass ich alle Variablen reinschreiben, die den String ".bStatus" im Namen haben. Nun würde ich gerne
Alarm
What is the procedure for creating alarms, I have some condition monitored variable from PLC. How i can create alarm with that variables. This is a migrated post! Originally posted on 29.06.2011 by user ansab.tp. Please be aware that information can be
facePlate configuration
Am planning Circuitbreaker faceplate, So i created one faceplate. But i have 25 circuit brekaers. How can i link the faceplate with other breaker. Is 25 faceplate needed seperately? This is a migrated post! Originally posted on 29.06.2011 by user ansab.tp.
DCO command variable isOnline question?
Hello, Every time when load project. All driver variables with IEC60870 protocol DCO or SCO command is offline. Is it possible to make it online without any command to send real command? My rema has alarm class "Control" and logging to Event list cell
Changed/new features from 6.22 to 6.51
Hello We have been using zenon 6.22 and we just bought zenon version 6.51. On the 6.51 I can find release notes regarding 6.50 to 6.51. Are there anywhere I can see all feature changes from 6.22 sp1 to 6.51? Kind Regards This is a migrated post! Originally
Archiv in SQL-Datenbank auslagern
Hallo, ich würde gerne Chargenprotokolle in eine SQL-Datenbank auslagern. Leider kann ich das unter "Archiv bearbeiten" -> "Speichern" gar nicht auswählen. Woran kann das liegen? Muss man noch irgendwo im Projekt eine Einstellung machen? Die Lizenz für
User Name and Password
Hello, I have Zenon CE project, i created for this project 15 users with different passwords, my quastion is if somebody forgot his password, is there any way to change or reset this password on the runtime self with out doing it on editor? Thanks in
access to variable adress in Runtime
hello i really need to access to the variable address in run time with this code i finde error :( VBA Code: Public Sub LeftClickDown_Default(obElem As Element) Dim var1 As Variable Dim myVal Set var1 = thisProject.Variables.Item("Feeder 404 Current")
CD_DotNetControlContainer problem with component registration
Hello I changed my special VSTA windows form (http://www.copadata.com/forums/showthread.php?t=1430). Now I have made it as UserControl in MS Visual Studio and inserted on the zenOn screen using CD_DotNetControlContainer. If I use this project on the local
Import Tagname from .csv file
Hello I am a beginner in VBA using. I want to import parameter Tagname from csv file. I read "Name" into variable tta_str and "Tagname" into descr, but I can not write Tagname into a variable. It is working only if I put into Item(" variable name ").
RGM-Rezepte in RT ändern
Hallo, arbeite mit der zenon Version 6.51 und beschäftige mich zur Zeit mit dem RGM. In der RT ist es möglich die Rezeptgruppen zu bearbeiten und Variablen hinzuzufügen. Diese „nderung wird auch für die Rezepte übernommen und die Werte der neuen Variablen
Driver for Siemens S7-1200
Hello. We have a siemens S7-1200 plc we want to communicate with. We already have the S7 TCP-IP driver fore some S7 300, is this the same driver for S7-1200?. How should we set the TSAP setting?. Is it anny other setting we have to change? Zenon 6.51
editing XLM
Hello I would like to edit xlm file (export variables from editor). I need to edit 3000 OPC variables. I have MS Excel 2007, but I can not import file when I save it in Excel. Thanks Jaro This is a migrated post! Originally posted on 16.06.2011 by user
World view overview
Hello, I have Zenon 6.51 SP0 Build3, i created one screen for world navi use (zoom in, zoom out,.....) and the problem that i dont have the worldview overview selection on the screen type option. please see the attached picture This is a migrated post!
Login Problem
Hello, I created a alogin picture with user name and password, i created new user administrator with pasword and i did all the necessary configuration, when i sheft to run time, giving me that the password.cmp file will not be overwritten as showing on
Aktuellen Gernzwerttext VBA auslesen
Gibt es eine Möglichkeit auf den aktuellen Grenzwerttext aus eine onlinevariabele auszulesen. Ich habe im Onlinecontair die Variabelle (mit 9 Grenzwerten) hinzugeführt. Bei Variabelle „nderung wir der VBA Code ausgeführt. Wie bekomme ich den zuzeit aktuellen
PictSwitch[0].Monitor problem
Hello I have trouble when using if (System.Windows.Forms.Cursor.Position.X >1920) { //position monitor 2 myFunctions.Item("Open_Trend_P2").set_DynProperties("PictSwitch[0].Monitor", 1); } else { //position monitor 1 myFunctions.Item("Open_Trend_P2").set_DynProperties("PictSwitch[0].Monitor",0);
Not DDE active by starting up
When I startup my zenon application and I read an variable, I get my own made error message "_GetZenOnVar - ValveOpen is not DDE Active" because I check if the variable is active. When I do an reload I didn't get this message. Also I check the variable
Advantage of ZenOn Energy version versus Standard version?
Hello, These days I am analyzing the differences between ZenOn Energy version and Standard version. I didn't find out many differences.. For example, if I get the ZenOn Standard version with "COMPLETE" license, I will have all drivers with unlimited variables.