Recent Topics
Polling Analog values each 1 second using DNP3.0 Protocol
Hi, We need pool Active Power and Frequency from a SEL-735 meter (Schweitzer) using DNP3.0 or other protocol with time stamp. Our client ask us to save data each 1 second (no by deadband). Could be possible with ZEE using DNP3 or another protocol (IEC61850,
"fpm.cmp" error
Hi I have a computer has install Zenon 7.50 runtime. Last time I use Zenon Editor 7.50 to config system, now I use Zenon 7.6 to config and compile/create runtime for 7.50 But I have a error :" If I change to create runtime for default (7.6) . I do not
establishing connection
hi i'm using zenon 7.6 with abb ac500 plc's, i have 1 driver of 3S_V3 with 20 controllers. in the office i have only 1 or 2 plc's, when i check the programs, every time i open or reload the runtime it takes forever to establish connection to the plc.
Integration of Alstom relays
Hi Support, Its possible integrate Alstom relays (like BM9100 or KMPC130) using K-BUS or another Alstom protocol?. Thanks in advance for your support. Regards, Jos© Luis Torres This is a migrated post! Originally posted on 18.04.2018 by user jose.torres@indexum.com.
Timestamp variable
Zenon is receiving data in DNP3 and after that It generate a report in the report viewer. The value of the time stamp that comes from the device is required in the report. How could I get it to show up in the report viewer report? Or how could I separate
Mit Button und Makro ein bestimmtes Bild öffnen.
Hallo, Ich habe mir 2 Buttons erstellt die übereinander liegen. Die Sichbarkeit der Buttons wird über die SPS gesteuert. Funktioniert ohne Probleme. Der untere Button wenn er von der SPS freigegeben wird soll mir ein bestimmtes Bild aufrufen.(Bild heißt
How to force webclient in to 64bit
Can someone help, Due to the large number of variable in a project circa 500,000 I receive "out of memory errors" using 7.60 webclient. I start the runtime in 64bit mode but all the webclients try and connect in 32bit mode. This is a migrated post! Originally
Change user authorization system screen
Hello. I have a problem. Does anybody know how to change this system screen? (In attachment) It showns when i try to change value in dynamic text element without authorization. I need to change language in this screen or try showns another screen. //
Visibility from 2 variables
Hello, Is any posibility to make a visibility depends of 2 different variables? Current status I have: -variable "Pos[BVAR]" where BVAR is changed for 10 positions (10 different blocks of HMI) -graphic with visibility from "Pos[BVAR]" (graphic is visible
Coloring like lines
Hi, I am using Zenon Energy Edition 7.60. I want to color any shape exactly like Line with using ALC. There is option to check "color from ALC "box for Line Properties , altough being same option for other shapes I can't use it. What should I do for coloring
ProjectServiceExtension Stop() - Freigeben verwendeter Ressourcen
Hallo, ich implementiere ein AddIn als ProjectServiceExtension und erzeuge im Start(..) einen Container für OnlineVariablen und Registriere hierzu ein Event. context.OnlineVariableContainerCollection.Create(AddInOnlineContainer_name); Beim beenden des
Mathematikvariable Wird Beim Nachladen Auf 0 Gesetzt
This is a migrated post! Originally posted on 26.04.2018 by user fineleric. Please be aware that information can be outdated.
World view frame
Hi, Is it possible to open a worldview screen with 0% zoom? I have a screen for world navigation with a size of 4400/2550. When it opens, it opens already with a 100%%zoom. Is it possible to changed that? This is a migrated post! Originally posted on
ProjectServiceExtension - Registrieren VariableChangeEventHandler
Hallo, ich implementiere ein AddIn als ProjectServiceExtension und verwende einen Container für OnlineVariablen. Hierzu möchte ich das Change-Event nutzen. AddInOnlineContainer.Changed += Leider gibt es den aus VSTA bekannten Eventhandler nicht im AddIn.
Report Viewer-Ansprechen der letzten Zeile in der vorherigen Reihe
Guten Nachmittag, Ich habe mit Report Viewer eine Matrix erstellt, wo ich Werte nach Uhrzeiten und Datum anzeige. Allerdings möchte ich bei "00:00"Uhr den letzten Wert der vorherigen Reihe anzeigen lassen. im Anhang befindet sich ein Screenshot der Tabelle
make runtime slow
Hi Team, I have Central monitoring system (CMS) & 4 plants (projects) integrated to it and each project has 3000 tags of event/alarm data that need to be archived. If I add all those tags, Runtime in CMS response slow. Can you guide for a solution? This
Message in unhandle exception
Hi I have a problem log /2/2018, 10:16:06 AM zenOn Version: 7.60 SP0 Build36068 Processor: UNKNOWN //----------------------------------------------------- Exception code: C0000409 The system detected an overrun of a stack-based buffer in this application.
VBA for command prompt
Hi I need a VBA code to call multi command in telnet in Zenon Ex : Call cmd.exe Call Sendkeys ( Telnet x.x.x.x) Wait time... Call Sendkeys (Enter) .. Call User Call Password But It can not work , It stop in Dos window and not send and keys after click
zenon 7 runtime mit windows 10 kompatibel?
hallo, ich möchte näschte , ein Runtime von einem im zenon 7.0 sp25 entwickten projekt mit Windows 7,in einem industry PC mit windows 10 installieren, wird es zu kompatibilitätproblem führen??? mfg This is a migrated post! Originally posted on 02.05.2018
email-nachricht aus dynamischer Grenzwert
Hallo, ich arbeite momentan auf einem projekt mit zenon 7.0 SP0 build 25. Ich hätte gerne zwei alarm emails bekommen. 1- email sollte die grenzwerte ( alarmliste ) von mehrere variable ( 3 ) enthalten . versuch : ich habe eine funktion ( mit sende nachricht
Error while runtime creation about variables which doesn't exists in database. Help is required to solve this error
Dear Team, Error while runtime creation about variables which doesn't exists in database. Help is required to solve this error. This is a migrated post! Originally posted on 04.05.2018 by user saravanan1985. Please be aware that information can be o
'œTime Stamp Issue in Zenon Runtime'
Hi, We want to show OPC variable with external timestamp in Zenon runtime, however, OPC driver is not listed in drivers which are taking care of status bits and data/time stamping. On the other words, when we receive a variable and it's corresponding
problem s7tcp32 driver problem when adding new variables
hello, I have added new variables to existing project of s7tcp communication driver. (zenon ver 6.51) I have added a new DB to the plc, and new variables are directed to this new DB. When I load to the screens a small red rectangle appears like there
Showing popup user32.dll
ZenRt32.exe Entry point not found , the procedure Entry point close touch Input could hand could not be located in the dynamic Link library user32.dll This is a migrated post! Originally posted on 17.07.2018 by user jarvis. Please be aware that information
UserChange() Event
Hello , i have a problem with UserChenge() event , when i change user in the runtime this event is not execute i don't know why . My code is below : Project_Active() = thisProject.Passwords End Sub [/FONT]_UserChange() MsgBox("it's working") End Sub [/FONT][LEFT]
SMS-Nachricht über SMS-Gateway
Hallo, hat wer Erfahrungen zum SMS-Versand über ein SMS-Gateway? Die Beschreibung in der Hilfe sind etwas dürftig, eine DIALOGS GmbH finde ich nicht. Wenn ja, welches Modem wurde verwendet? Welcher SMS-Server wurde verwendet? Was muss bei der Konfiguration
Alarmstatuszeile
Hallo, zenon 7.10 Ich verwende bei einem Projekt die Alarmstatuszeile. Nach einer Wartung des Servers, inkl. Einspielen aller Windows Updates, erscheint nun zusätzlich zur Alarmstatuszeile ein Fenster (Status) in der Taskleiste. Wie kann ich das wieder
Setting tool tip for multiple instance of a symbol
Hi . I have a symbol that is used in various places in project , and i need to set tool tip for each of them. I used a button with transparent background with tool tip enabled , but it will be shown for all instance of this symbol and i can't modify it
Logic, a loop for an array with type variables
Hello, I have a type BatteryInRack: Voltage: real; Ready: bool; and a type BatteryRack: Battery1: BatteryInRack Battery2: BatteryInRack Battery3: BatteryInRack ... I have in Logic a variable: BatteryRack: BatteryRack I try to assign a value to the Voltage
Styles content is not visible in Zenon 7.60
Hello, Please find the attached screenshot, STYLES are present but not visible. Please suggest the settings regarding it. Regards, Rahul. This is a migrated post! Originally posted on 11.05.2018 by user rahulindore05. Please be aware that information
Kurvenreihenfolge In Trendbild ändern
Hallo zusammen! Ich suche eine Möglichkeit um die Reihenfolge der Kurven in der Kurvenliste von Trendbildern zu ändern. Die Bildumschaltungen, die die Bilder aufschalten und die Trends parametrieren sind schon vorhanden und fertig. Jetzt soll aber die
SICAM 230 Editor Licence
Hi Team, I am facing issue with SICAM 230 Editor licence. I have a Wibu key [Dongle], Licence sheet, Serial 7 , SICAM 230 Key7 , Activation Key 7 placed in zenon6 ; C:\ProgramData\Siemens\System My licence below; ACTIVATIONKEY7=2XXXXXXa SERIAL7=8XXXXX1.101006.8.0
email-nachricht aus dynamischer Grenzwert über smtp
hallo , ich möchte eine email aus dynamischer Grenzwert über smtp senden . zudem sollte dies auch in der alarmmeldeliste angezeigt werden . Problem: Wenn die variable verletz werden , werden sie nur in alarmmeldeliste angezeigt , und werden keine email
Remote: Reload project do not works
Hi boys! Any ideas why "Remote: Reload project" toolbar button do not works on some WSB and works well with other ones? On a WSB where reload project failed "Remore: Close runtime/Start runtime" tool bar buttons work as expected. All projects are set
Quittieren von Alarmen per Doppelklick deaktivieren
Hallo zusammen Ich benutze Zenon 7.20 SP0 Gibt es eine Möglichkeit das Quittieren von Alarmen per Doppelklick zu deaktivieren? Die einzelnen Alarme müssen selektierbar bleiben. Einstellungen auf dem Bild und auf der Alarmmeldelist für Doppelt-Tippen habe
Berechtigung für Quittieren in AML und Statusleiste
Hallo, ich versuche gerade vergeblich das Quittieren in der AML und auch für die Alarmstatusleiste einzuschränken. Ich würde das Quittieren gerne nur einem Benutzer erlauben. Dazu habe ich folgendes gemacht: -Im Global-Projekt den Benutzer angelegt -Dem
Reg: DPC Testing with varibale daignosis
Hi Team, Thanks to all your support in forum. I have a iec850 device which has double point. How can i test in varibale diagnosis. Simply adding variables will work or Do I have to create anything to test. Regards Sarav This is a migrated post! Originally
DiagViewer: CT-type definition corrupted
Hi guys, The zenOn Diagnostic Viewer shows my the following error text when starting the straton runtime on my PC: >>> Project 'myProject': Expanding complex type for 'myVariableStruct' failed. CT-type definition corrupted. The variable myVariableStruct
Webserver findet Lizenz nicht mehr
Hallo zusammen, woran kann es liegen, wenn der Webserver mitten im laufenden Betrieb plötzlich seine Lizenz nicht mehr findet? Während dieses Betriebs wurden keine „nderungen an der Hardware vorgenommen und keine Updates installiert. Der Webserver geht
Create dynamic Alarms via API
Hello, im looking for function to create various Alarms via API, is it somehow possible? Also i want to remove those alarms after acknowledgement. Thank you! This is a migrated post! Originally posted on 17.05.2018 by user keelektronik. Please be aware
Next Page