Recent Topics
How to replace links/indexes in fuctions called from substituted screens?
Hi @all, I have created a screen (s1) containing screen elements related to variables. This screen is opened by a function (f1) with an indexed configuration. This function is called by a navigation context with a parameter for substitution. I have created
Add-In Debug Target
Hallo, ich habe mehrere Projekte im Arbeitsbereich und möchte ein Addin in einem Unterprojekt Debuggen. Beim Debuggen kann ich in den Projekteinstellungen von Visual Studio das zu verwendende Projekt in der Runtime auswählen (Debug Target). Leider wird
Zenon 6.51 OPC Server Configuration
Hello, Can anyone please share manuals for configure OPC UA Server in Zenon 6.51 runtime. I have to transfer data with OPC UA from Zenon 6.51 to client side Scada. If anyone have sample project, please share.... This is a migrated post! Originally posted
Change global variable from PopUp window
I need help in typing function. I have some buttons, what call PopUp window. And i need change value of global variable on button press vulue = variable name on this button This is a migrated post! Originally posted on 19.11.2018 by user xxxd0nixxx. Please
non-linear value adjustment macros - how to set values without endless loop?
Hello, after long searching and trying I came to no result. These options are poorly documented and I didn't find any examples. In the help one can find this: AdjustScadaValue Only available, if non-linear value adjustment is active: Macro is executed
Message control zenon6.ini
Hello, I have noticed that the zenon6.ini file are not the same on the primary server and the standby server. I am configuring an SMTP functionality and I noticed that I need to copy the [Message Control] section from zenon6.ini file on the editor PC
HTML5 und Redundanz
Hallo, ist es möglich das der HTML5-Client sich per IIS zu mehr als einem Server verbindet? Beim Deployment Tools lässt sich anscheinend nur ein Server angeben, laut Hilfe. Wenn wir auf dem Server, der als ConnectorServer in der Web.config steht, die
IEC 62056-21 Driver
Hi, I am trying to use the IEC62056-21 driver in Zenon 8.0 to read values from a CEWE Prometer however I am unable to get Zenon to communicate to it. The meter is connected to the computer via a serial cable, it is set as RS232 with the following setting
Change color palette via VBA
Hi all. How to change (switch) color palette via VBA? Idea is to save color palette internal variable (integer) which is remanent. On scada startup I should to check value of that variable and set color palette which depends of that variable state. BR,
zenon 7.50 64bit, HTML Seite mit AXIS IP Kamera Problem
http://www.axis.com This is a migrated post! Originally posted on 08.11.2018 by user Jusufs. Please be aware that information can be outdated.
I've Just Started
Hi everybody! I started the Zenon 7.20 Energy Edition and I need help to use. 1)- I want to create a new workspace. (154kV/33kV substation automation) I want : automatic alc, Alarm page for 154kV and 33 KV, circuit breaker control, navigation vs. How
Name von Alarmgruppe ermitteln
Hallo alle Miteinander, kennt ihr eine Möglichkeit wie ich aus einem auftretenden Alarm ( ZAlarm_AlarmEntryReceived - Event) den Name der Alarmgruppe bekomme? Also ich bekomme die ID der Alarmgruppe über .GroupIndex.... ich bräuchte aber allerdings den
unknown error occured while accessing an unnamed file
Hello Team, I am getting an error, when I add variables in historian and save project. Here I have attached image file containing error. Please let me know reason for the problem. It will be helpful. Warm Regards, Shiva This is a migrated post! Originally
Straton PT input as ms
What is the procedure to input timer PT values as something other than seconds? This is a migrated post! Originally posted on 01.11.2018 by user Geezerglide. Please be aware that information can be outdated.
Variable XML export/import
Hi to all! Story goes like this. I have successfully exported all variables to XML file. I have made some changes to XML file (for example: field for showing variable limit value in AML changed from FALSE to TRUE) and saved it. After the changes I have
Read zenOn variables from Windows Service
Good afternoon. I want to read variables value from zenOn Runtime project using zenOn API. I'm working with 7.60 SP 0 Build 36068 zenOn version. If I use a simple C# Console Application everything works correctly. I have an exception in the below function
Recipegroup Manager About the "Write all values" button I would like to ask a puestion
I added a new recipe item to an existing recipe using the "Edit recipegroup" button on the "Recipegroup Manager"screen. [variable selection]screen opens... Item_01 EDF (0) 115.1634.00 ・ ・ Item_10 EDF (0) 115.1670.00 Item_11 EDF (0) 131.1530.00
Creating all in to PDF
Dear Team, Can we export all reports into PDF which we are Viewing in LOT Filter. Instead of opening each and printing -- can we do all Lot filter files Warm Regards Srikanth G This is a migrated post! Originally posted on 25.10.2018 by user Srikanthg.
Reg: Evacuation in sql not visible for Project IDs
Hi All, Project ID is not listing in table creation for sql during historian archive. Please support what might be the issue? Thanks Sarav This is a migrated post! Originally posted on 27.10.2018 by user saravanan1985. Please be aware that information
Variable Maximum over 1 day with time stamp of when the maximum was recorded
I have been asked to make an alarm list entry of a maximum value over 1 day from PLC variable with time stamp of when the maximum was recorded, so the user can look back at the last 30 alarms that will show the maximum value and time the value was recorded
ConnectionState variable
Hi! I'm using Zenon Energy Edition v7.6 with the IEC61850 !ConnectState Variable to detect communication error for ALM with a certain IED in my project. But the variable never goes to TCP_CONNECT_ FAILED when i disconnect the RJ45 cable from that IED
REMA Dynamic limit value text
Dear colleagues, I have REMA which contains error codes and messages. The back end PLC code with updates may receive new new error codes which won't be declared in Zenon yet. To handle unknown error codes I have activated "Default value" with Dynamic
2 Sollwerte mit Combielement setzen
Hallo, ist es möglich 2 Sollwerte über ein Combielement zu setzen? Folgendes Problem will ich lösen, nach möglichkeit ohne freie Programmierschnittstelle. Ich habe ein Heizlüftersymbol, wenn ich auf das Symbol klicke, öffnet sich die Steuerungsseite dazu.
General Interrogation Fail in 61850
Hello, I am working Zenon Energy version 7.20. Zenon communicates with many SEL relays using 61850 protocol. I want to use RCB, but I have problems when the RCB are activated by Zenon. If I use polling mode everything works well and the representation
Netzwerklizenzierung
Gibt es eine Möglichkeit eine Lizenz bzw. eine Seriennummer von einem Netzwerkserver in die Licence.ini eines lokalen Clientechners zu übertragen, ohne diese händisch zu kopieren/editieren? Folgendes Szenario: Wir haben eine Seriennummer unter welcher
Sub Project in Webserver Pro Lite
Hello Team. I have got a Web Server Pro Lite license 3 Clients. I have one main project and one sub project inside the main project. Neither of them are client projects. I have linked the sub project to my main project via screen switch and vice versa.
control 2 variables in graphic/pushbuton
hi i would like to know if it is posible in a graphic/pushbuton to control to variable at the same time for example a BOOL value and an analog variablestate of the button will be only the BOOL variable of course This is a migrated post! Originally posted
Ce 6.22 sp1
Dears,can you send me the CE Installation as it was a separate setup in version 6.22 sp1 ? EMAIL: Very thanks This is a migrated post! Originally posted on 10.10.2018 by user junzai1002. Please be aware that information can be outdated.
zenon CE 6.22 sp1
Dears,can you send me the CE Installation as it was a separate setup in version 6.22 sp1 ? EMAIL:978809376@qq.com Very thanks. This is a migrated post! Originally posted on 10.10.2018 by user junzai1002. Please be aware that information can be outda
Embed symbol checkbox.
Hi, I want to modify variables by zenon Logic, but cannot manage to check "Syb." checkbox in Straton. I'm getting message "The variable is currently locked". Any idea what should i do? This is a migrated post! Originally posted on 09.10.2018 by user www121212.
Operator Extended Trend not displaying on RT computer
Hi All, I set up an Extendend Trend screen with the Standard Scada 1920 template. I configured the screen switch function to read 23 tags from 2 different Historian Archives, edited some curves names... It works well on Editor Laptop, when i switch the
Integrate/Connect/Link HMI graphic with PLC instructions
Hi COPA DATA I want to ask regarding on how I can link/connect/integrate my PLC instructions with HMI that I created in Zenon. Currently, I am using WAGO 750-8202, DI card (part number: 750-1405) and DO card (part number: 750-1504). I read the manual
.rdl file (Report Viewer) shall open in Report Builder
Hi, I've Zenon 8.0 and want to open a .rdl file within Report Builder 3.0 (additional installed) for editing. But all the time when I try to open the .rdl from within Zenon, Visual Studio opens. Is there a way to define that Report Builder shall open
Build Installation Errors
Dear Team , Most of the cases we are facing issue in installation of new builds, screenshots are attached. Can any one share links for Zenon 7.00 build 32 and Zenon 7.11 build 45643. Warm Regards Srikanth G This is a migrated post! Originally posted on
Straton Reading Wrong System Time
Hi Guys I am using get curdatetime block in straton to read the system time(which i use for a logic) in the Server, Now the problem is the block is reading the UTC time but i need UTC+5.30 (my system time is already UTC+5.30 only). The same logic is reading
Redundant Ip address changeover event in CEL
Hello Team, In energy drivers wherever secondary IP address is possible, I want to generate an event or Alarm whenever a changeover happens from primary to secondary IP. I want to achieve this without using SNMP. Whether I can get an event from my IEC60870
Archive data in azure
[LEFT] [/FONT] In one of our projects, we have successfully, exported the archive data from Zenon to SQL Cloud.[/FONT] But we are getting TTL Expired exception error. Because of that messages are moving to the deadletter queue.[/FONT] [/FONT] 1) Is there
How to use gateway in Zenon Energy
Hello everyone, I have a question. I usually use Sicam 230 and I use the section "Gateway" under "Variable" menu for example to translate a SinglePoint 61850 stVal status variable to a IEC 60870-5-104 variable M_SP_TA_1 (ASDU 2: Single Point with timetag).
Get User Group Level Number
How can I get User group Level Number Not User Group Name ? I am getting User group Level name from get_dynproperties("UserGroupLevel") in C#, But what I want is User Group Level Number. or I there any way I can find out User group Level Number from UserGroupLevel0,UserGroupLevel1,UserGroupLevel2
how to share variable from external PLC to other PLCs in the network using Zenon SCADA
I am reading wind data from Delta PLC using Modbus TCP/IP. I want to send this wind data to other PLC Slaves(Delta) in the network using Zenon SCADA. Is this possible without using Zenon Logic? Thanks Lingelethu Dyasana. This is a migrated post! Originally