Recent Topics
how to share variable from external PLC to other PLCs in the network using Zenon SCADA
I am reading wind data from Delta PLC using Modbus TCP/IP. I want to send this wind data to other PLC Slaves(Delta) in the network using Zenon SCADA. Is this possible without using Zenon Logic? Thanks Lingelethu Dyasana. This is a migrated post! Originally
Change BOOL state with PopUp window
Hi guys, I only begin to learn Zenon and at the moment I need to change with PopUp window. I have some Switch and I want after click on them see PopUp with buttons (Turn on/turn off) and after click on this button change switch state. I create screen
Need some help for two simple things
Hi, I inherited a Zenon project and have to add a new PLC and some new functionality to it. System is Zenon Supervizor Version 7.60 SP0 Build39532, PLC is Festo CPX-CEC-C1-V3 (Codesys 3), so I'm using the Codesys driver (3S v3 driver for PLC handler).
SMTP without POP.
Hello all, At one of our clients I can't get Zenon 7.60 to send e-mails by SMTP. The client does not have a POP server, only a SMTP server. Sending e-mails by SMTP with Powershell works fine. The client gave me the following settings: SMTP: bla.blabla.nl
Levels/Layers in Zenon
Hello Team, Is it possible to activate and deactivate layers/levels in runtime? That is, suppose I have made a screen using different levels. When I deactivate/invisible a level the graphics in that level disappears from the editor, and when I activate/visible
Static text box to blink
Hi everyone, I am very new to Zenon product and I am barely know about the configuration and so on. Currently I am developing one HMI panel which later to be integrate with WAGO PLC. I am using Zenon Energy version. Question is: 1) How I can make my static
Status bits actions in reaction matrix do not enter entries into CEL/AML
Hello Team, I have configured a reaction matrix to execute a function and to create an entry in CEL/AML whenever the status bit 'off' changes. Although the status bit is changing, neither the function nor the CEL/AML entry gets executed. This same I have
Alams/ Events Deletion
Hi, Support. Is it possible to delete Alarm & event of a specific (absolute) time period ? or few specific alarm or event ? If yes.. Please explain the same. Thanks in advance. This is a migrated post! Originally posted on 21.09.2018 by user azami. Please
How to change mouse coursor - Runtime
Hi I have a question about mouse cursor in the Runtime. Is any procedure how is possible to change mouse cursor for screen switch or commands as well (for example from "hand" to "arrow")? Thank you Stan This is a migrated post! Originally posted on 26.09.2018
Variablen, Bilder, Funktionen etc. in Gruppen (Ordner)
Es wäre echt super, wenn es wie bei WinCC die Möglichkeit geben würde Variablen, Bilder, Funktionen, etc. in Gruppen (Ordner) unterteilen zu können, damit man das Projekt übersichtlicher gestalten kann. This is a migrated post! Originally posted on 20.09.2018
Historian Read Back
Hi, Please help me on this issue: In the case with architecture of using Historian Computer working independently with Server Computer, is there anyway to store database in both Server Computer and Historian Computer? As I see Server Computer will save
Reg: Unable to restore backup in particular laptop
Hi Team, Good Day. When I tried to restore in a specific laptop this is not restoring. Below is the error image i am getting. Please support Thanks regards sarav This is a migrated post! Originally posted on 19.09.2018 by user saravanan1985. Please be
Multi-binary Reaction matrix problem
Dear Team, Zenon Version 7.50 Build 49034 We are receiving Alarms from OEM machine using variable UDINT datatype Example: - Alarms are triggered bit wise (1, 16, 17, 19, 20) then we have written VB script for receiving it and moving to individual Internal
Recipe not loaded properly
Hello, I have a problem with straton: I want to save+load some values using the integrated recipe manager. However it appears that some values are not saved/loaded properly ! The same problem appears by saving or reloading values to/from the recipe. Here
WMI Treiber
Moin, gibt es eine Möglichkeit / Treiber eine Schnittstelle zur Windows Management Instrumentation (WMI) zu schaffen? Wir haben ein Netzwerk, in dem nur einzelne MAC-Adressen freigegeben sind. Wir würden nun gerne eine Meldung in der Ereignisliste oder
I want a from date time and to date time of report filter in my rdl file
Dear all, I'm using zenon 7.50 with build 49034, i want From DATE TIME and TO DATE TIME of time filter to my rdl file , i'm linking my report function to absolute time filter with propose current date and time from the above picture if i put from and
zenOn Logic - speed-up download?
Hi guys, I would like to know if there is a way to speed-up the program code download from zenOn Logic to the target. Right now on my development PC with an application code APPLI.XTI / STRATONRT.COD from about 1.2MB, it takes about 40s to download to
Variable deactivation and alarm deactivation from Runtime
Hello Team, Is it possible to deactivate a variable(or many) and alarm from the runtime. ? That is the variable deactivated from the Runtime should not be ever polled until I activate it back and the Alarm deactivated for any variable should not show
Checking communication presence with secondary IP address(device) while primary communication is established
Hello team, In many of the drivers, we have option to enter a secondary IP address/ redundant IP address. In my case IEC 60870 client driver. My requirement is, while my SCADA is communicating with the primary IP address in the driver, I want to check
Archive values after communication loss
Hello Team, Once communication with the PLC is lost, my archive logs the last updated data. I want to log '0' in each tag once communication is lost. Please suggest. This is a migrated post! Originally posted on 08.09.2018 by user joelprasad. Please be
Error during license update
Hello Team, I am facing an error when I am trying to update my license from 1 year to lifetime using Wibucmrau file. I have attached the screenshot below. Please suggest. This is a migrated post! Originally posted on 08.09.2018 by user joelprasad. Please
Maximum Number of bytes will be polled (Read) by zenon in S7TCP driver - Profinet network for each priority (Normal, high, higher, highest) variables
Hello Team, I want to calculate the variable update (read) time by zenon based on priority set for more than 1000 variables. i.e. how much time it will take to update the variable value in zenon for variables which are prioritized as Normal, high, higher,
Project wizard extension in eigenem Thread ausführbar?
Hallo, Ich nutze VS2017 um ein "project wizard extension" zu erstellen. Im wesentlichen führe ich eine Bildumschaltefunktion aus und mache anschließend einen Screenshot. Im debug-Modus aus VS2017 heraus funktioniert alles einwandfrei, weil scheinbar das
F_DELETE false
How to figurout why file wont delete? Image attached. This is a migrated post! Originally posted on 06.09.2018 by user klasik. Please be aware that information can be outdated.
Alarm-Quittiervariable absetzen nach Verbindungsverlust SPS-Treiber Open Modbus TCP
Hallo, über die Alarmverwaltung von Zenon (v7.60 Build 49005) quittiere ich, mit Hilfe der steuernden Quittiervariable eines Alarms (Quittierwert 1), eine auf TRUE / 1 gesetzte Störungvariable in einer SPS (ABB AC500 PM583-ETH) wieder zurück auf FALSE
Webserver with Zenon Operator
Hello Team, Does Zenon Webserver works with Zenon Operator? This is a migrated post! Originally posted on 01.09.2018 by user joelprasad. Please be aware that information can be outdated.
Workspace restore error
Hi, I was trying to restore a workspace backup but getting the error always. I have tried this in another laptop but same situation any one can help? Sandy This is a migrated post! Originally posted on 30.08.2018 by user sandeep2018. Please be aware that
Zenon operator station
Hi, I would like to know how to create a zenon operator in my project. I am planning to use 15'' IPC with I3 for the operator station any guidance for this would be appreciated Regards Sandy This is a migrated post! Originally posted on 28.08.2018 by
Error while giving open command ti the RTU IEC 608710 104 Protocol
Hello Team, I am not able to send open command to the RTU in IEC 60870 protocol from the SCADA. I am able to send the close command though. I tried the same thing using a IEC 104 simulator and I was able to send both the commands open and close. While
Oee
Hi, I would like to know if there is any templates for OEE calculation in Zenon copadata Regards Sandy This is a migrated post! Originally posted on 26.08.2018 by user sandeep2018. Please be aware that information can be outdated.
Modbus Process Gateway Error
We are using Modbus Process Gateway to transmit values to the DCS system. The DCS can receive information from Gateway, but once the DCS sends command to Gateway, Gateway terminated with error: Exception code: E06D7363 Fault address: 74A74598 01:00013598
Driver Mode Switching recommendation?
Dear Team, I'm using Zenon 7.50 Build 49034 and multi-project structure with Three different drivers. I want to stop communication when no communication from controller kindly suggest Driver Mode switching Functions 1.For starting Driver ----> a) Driver
Siemens PLC to Zenon - Variable update time delay in S7TCP driver - Profinet network
Hello, In my project i am using Siemens CPU 319 and in zenon S7TCP driver was used to communicate with PLC in Profinet network. Total 4200 PLC variables are created in Zenon. Out of 4200 variables 1200 variables are used as permanently read variable.
Permanently read variable
Hello Team, If a variable is enabled for permanently read variable how is that variable polled by Zenon. (Time interval)? This is a migrated post! Originally posted on 24.08.2018 by user joelprasad. Please be aware that information can be outdated.
Error while importing cfg file in comtrade viewer
Hello Team, I am facing an error while I import the .cfg file in the Comtrade viewer. I have attached the screenshot below. Please suggest a possible solution. It happens when I click on open button and select the .cfg file from the extraction folder.
Unsolicited DNP3 Communication with Zenon 8.0
Dear Support, I am getting the unsolicited messages when my RTU connected to in ASE Tool as Master. However, I am unable to get the Unsolicited message frm same RTU in Zenon runtime v8.0 . I am attaching the Zenon DNP3.0_TG Driver setting i did, for your
Default Function "Display unused variables" have problem
Dear Team, I'm using Zenon 7.50 Build 49034 and multi-project structure. When I active 1st project and select default Function "Display unused variables" it will not show all the filters within the project. Next if i active 2nd project and select default
Recipe combobox not refreshing after create
Hi, I'm trying to modify an existing recipe name from code-behind and also create a new recipe. The changes seems to update after i switch back to the standard recipe page. But the recipe page does not update its content (like the combobox) while the
SQL export
Hi I use the SQL export function in zenon 7.6 but I have 2 question : + When zenon automatic export archive to SQL by cycle or change values or should has function to export archive to SQL + The table are created in SQL by Editor different than the table
Alarm Sound bei Störmeldung
Hallo, ich bin auf der suche nach verschiedenen Alarm Tönen? Bietet Zenon da keine eigenen Sounds? This is a migrated post! Originally posted on 16.08.2018 by user crz. Please be aware that information can be outdated.