Recent Topics
Did someone know the technologies used by Zenon scada ?
Hello i try to find which technologies are used by Zenon ( like java, or .net, or simples exe ) ? thanks in advance for your help regards
RtFunctions - Dynamic Property
Hi! How can i use this dynamic properties in vba? (see attached photo) i have tried but without success. Mainly interesting me this one - "CFktOnlineDruckUmschalten". This Dynamic function let me change set printer in runtime using vba without using popup
Dynamic change selected Printers
Hi ! Is possible to dynamic change selected Printer? (for example using VBA or any else way) in Runtime i need it because i have 2 type of report and both should be print on 2 different printer. Thanks for advance
command processing screen
hey I'm learning on zenon energy basic edition in zenon academy but when I reached the command processing chapter, I followed the same steps but the screen is not working with me. can anyone help me ? when I open the diagnostic viewer it says that the
Recipe change logging
Is it possible to log recipe changes in Runtime with date and time, the recipe changed, which parameter was changed and who changed it? I've heard that the CEL could be used for this but don't have the details. How would one use the CEL for this? This
connected clients diagnostic
Hello, I have a multi-hierarchical project where the main project is the server and the children projects are the clients. I want to monitor the connection status of the clients. I tried to use the variables of the SYSDRV "Names of connected clients"
Iec 101 slave
Hello support How to use Iec 101 gateway to communicate with more then one master I mean how to send signals to different master using different serial ports in one gateway Best regards
Archive XX Data couldnot be read completely. Please set a shorter time priod.
One archive created with 80 variables, type real. Make screen with control element DiagramWindow, and show 4 variables. when try to switch to screen with this control Iget message: [h=2][/h]I used for Time, this settings Relative time period 00 days 12
Message Control and Alarm Groups
Hi, In my ideal setup I would like to link the sending of the message including Limit value text to a alarm group. But sadly I am not able to acess the limit value text of the alarm variable if the sending function is linked to the alarm group. What is
Override Data
Hi all, Is there any module or tools i can used to override or monitor the variable without using service engine?
Historian
Hi all, I have separate Historian server and Service Engine Server. How do install this two module separately. Since there is no option to unselect historian module during installation.
No database access project zenon 7.6 after install zenon 10
hello I have two zenon 7.6 and zenon 10 licenses I currently use version 7.6 for my projects, I wanted to install version 10, everything went well but now I can no longer load my projects in version 7.6 because it tells me that the databases are not accessible
html screen from service extension addin
Hi, I'm trying to make a service extension that will popup a window to create html screen and specify it's URL. I can already create all the frame and screen for the html but i need to create switch screen function from the service extension that i can
Reading RDA Array(Real Data Type) from Beckhoff Twincat NG Driver
Hello, Our requirment is to capture live data from PLC (Real Data type) and capture it in Extended Trend. We have to capture live data for every 10 ms from the PLC. We have created RDA Array[50] inside the PLC of Real Data type and provided the data from
IEC60870-5-104 Settings for redundancy with Sicam CP-8050
Hello. I have two Sicam CP-8050 that is in redundancy. I have Zenon 10 as HMI. The driver I have set-up The Zenon driver has a primary and secondary connection. Whit Redundancy according to 60870-104 edition 2.0. The problem is when I'm forcing the
Zenon Logic logs
Hi Can you give me more information about this logs, what does it mean exactly. Project 'G5': Reading object '0x02' (project state) failed. Return code '-2' Project 'G5': Reading object '0x01' (project state) failed. Return code '-2'
Export Old ARX Archives Independently
Hi, I have large sets of data that are evacuated on ARX archive file format. I want to export these archives to CSV or SQL without Service Engine. Because there are tremendous data and exporting these archives with the export archive function are freezing
Additional structure element created from existing program does not shown the value in HMI
Hello, I am working of existing and running Zenon project 7.6 created in ZEE. Running in Network Active ServerA and Server B with software redundancy and dominant mode. I added 2 structure elements to the existing structure datatype and assigned UINT<Embedded>
Monitor Profile
Hello everyone I hava a project with Energy Edition v8.1 ,normaly there is a standart monitor profile in monitor administration, but my case there is not standart monitor profile and I can not add new profile ,how can load or retrive standart monitor
make multiple variable in zenon editor on picture
Hello everyone, i am working on project , where i need to make more then 500 small circle on pictures by detecting specific line one that picture. basically it should find out length of line from that picture and and make circle according to that diameter
priority in logic
Hello, I have a problem that I can't solve
I have Logic
There are more than one input variable
Each variable has priority in color
And I have a variable that represents the state of the connection.
When making a logical equation
I couldn't get the color
Segregation of System events and Process events
Hi, How can i segregate system Alarms/events ( Log on/off, memory quota etc ) and Process alarm/events ( CB open , trip etc). I have not found any filter for system alarms or Process alarms. This is a migrated post! Originally posted on 22.02.2012 by
Report Viewer AML Filter
Hi I made a report of the whole aml and now im trying to filter the list. Best case would be if i can set a filter value (text) in the runtime and then open the report. The report should filter only the alarms with the filter text in it. I made two datasets
regarding alarm abnormality
sir, in my project there is a problem by which all alarm are suddenly enabled due to a raw valve #2147483647. when this raw valve arrive ,then all bit will be high and alarm will be enabled. so this is a false state. how to disable all alarm when all
Zenon Process Gateway OPC DA server
How to configure Zenon Supervisor as OPC DA server from Process Gateway or any other method?
6.22 running on Windows 10
Hello, we need to change PCs in an older installation. Currently Zenon is running as 6.22.0 on Windows XP. The license is on an LPT dongle. Question: what version is neccessary to run the 6.22.0 and also the LPT dongle under Windows 10? Is it possible
Constantly running VBA Script
Hi All, New to the Zenon platform, have to create a project with VBA logic as there is no PLC available to do the logic. This particular logic is to control the OneLine but there will be more. What I am trying to do is to run a VBA script every 1 or 2
Siemens PLCSim
Hi MarkClemens I have a Zenon software for touch screen and PLCSim from Siemens... i just wanna know if is posible to work togheter...thank you This is a migrated post! Originally posted on 12.03.2008 by user gh_ounie. Please be aware that information
Regarding error message while run time
sir, im working with a project which contain to sub project. It consist to separate zenon logic for both sub project. while runtime there is a error pop up is generated .its attached below. how to overcome this error
Keyword not found
Keyword "RobError+S01=006-KF01.120_ROBOTER_2.stSchnittstelle.stInput.stJobhandling.nFehlerNr;" not found: ROB2_Error_02[8] (the element will be selected via double-click) above error comes when i implement the text into Limit value text "$ROB1: ;%@RobError+S01=006-KF01.120_ROBOTER_2.stSchnittstelle.stInput.stJobhandling.nFehlerNr;"
Password.cmp encryption
Hello, Hope all are doing good... I would like to know more about password.cmp file. All user access data is stored in password.cmp file. right? And these files are encrypted. right?(customer cant able to access the data inside.). So is it possible share
XML Editor that works with Zenon exported files
Dear Community, Please recommend an XML editor which works with format of Zenon exported files. I'm trying to export some variables and edit them, since variable type is an array I can't edit them in CSV or dbase format. I can edit XML file in MS Excel
Alarm on Standard Scren type
I have a Project which has a main page. same like SIMATIC HMI, I wanted to show only last 2 alarms. either alrams are active or not , wanted to show those with time stamp into Standard Screen ( as main screen is Standard Type ) what is the method to
Zenon DMS Demo
Dear Community, Can anyone provide Zenon DMS Demo project backup? Preferably version 8.20
zenon OPC Server can not add tag,OPC DA Server
Dear All, I need to connect "zenon OPC Server for version: 8.20.92659" to KepservrEX OPC DA Client. I already Registers the OPC server,Set EVENT=1 . OPC Clients can see the zenon OPC Server but I can not find and to browse the variable My Zenon Sup. is
Web Client Questions
Hello, I'm KIM. I have a Web server related questions. If i use Web server, I'd like to know whether the fuinctions are supported in Web Client. 1. Recipe - Execute, Edit 2. Report - Export Report, Printing 3. User account - Add, Delete, Edit Please
how to re-install the zenon runtime 6.22 sp1 on a WINDOWS CE-Platform?
how to re-install the zenon runtime 6.22 on a WINDOWS CE-Platform?very thanks This is a migrated post! Originally posted on 18.04.2017 by user junzai1002. Please be aware that information can be outdated.
Download or Buy WPF Elements?
Where can I buy (or free download) WPF elements ?
How to change text after statictext+DynamicValue together
My Question is related to limit value text : i have FIX_TEXT + Variable value --> then i get a value like ERROR# + 10 : Error#10 then i wanted to change this Error#10 ---> "any Text related to Error explanation !!! " i cannot do @ LanguageFile"textChange"
Connection of two DNP3 Masters in Process Gateway
Engineers I require your support, currently in the project we are working on we have two computers where a local SCADA is running with its respective CPU1 and CPU2 redundancy in (Zenon 8.0), level 3 reporting is required, this to two DNP3 masters with