Recent Topics
Zenon server & Client Connection
Hello Everybody Am facing one problem in Zenon Run time Server and Client connection establishment. I have installed Zenon run time & Web server in one machine and Client on another machine. I am getting screens from Zenon Run time to Zenon client machine
VB .net program
Hi I want a Vb . net console program with no interface to read a cmp file for a system and write out all records for a certain issue date month.Suppose we take a existing cmp file i need all records with issue dates as January in a new cmp file.we have
Remote transport
Hi, I can not establish connection with remote computer. When I try to ping computers IP or name, ping works fine. Ater REMOTE TRANSPORT: CONN. SETTINGS, I pick remote computer name and after clicking on ESTABLISH CONNECTION, message appears: "ESTABLISHING
VBA "License information for this component not found"
Hello! I am having an issue with an issue with the VBA on a customer PC. The zenon Editor and Runtime were installed without an error message but I am not able to use the VBA properly. As soon as I activate the "EVENT=1" I get the Error message from the
Modbus Process Gateway
Dear All, I am trying to use the "Modbus" Process Gateway in Zenon 7.11 for data communication. There is no data transferring through gateway. How can we know the Process gateway is transferring data or not? Please note the following, 1. I exported the
Welche Variable ruft Makro auf
Hallo, wir arbeiten mit der Version zenon 7.1. Beim überschreiten eines Grenzwertes soll ein Macro in VB.Net aufgerufen werden. Wie kann ich schließlich in VB.Net auf die jeweilige Variable in der Funktion zugreifen? Es wäre nett wenn mir hier jemand
Message control using USB GSM modem
Hello. My GSM Modem is USB not Serial. In the manual, noted that only serial GSM modem should be used in message control. Isn't it possible to use usb GSM modem? Thans. This is a migrated post! Originally posted on 17.06.2014 by user jessica. Please be
Popupfenster bei Mehrmonitor-Projekt
Hallo zusammen, ich habe eine Funktion definiert, die ein Popupfenster öffnet. Die Funktion wird auf jedem Rechner ausgeführt. Wenn dieses Popup-Fenster einem Bildschirm zugewiesen wird, den ich nicht an jedem Rechner habe, wird das dann an Rechnern mit
VBA screen switch on multi-monitor system
Hi to all I use zenon 7.11 with 2 monitors. I have some popup screen which I start by the screen switch function from VBA code from combined element. I use VBA code for some substitutions of the replace links of the my RTfunction. My combined element
Convert wincc Zenon
Hi, I need to convert a project WinCC in Zenon know there are 2 tools ("WinCC Graphics Converter" and "WinCC impor Wizard") not is if they are independent to Zeno, can not find the installation package. Thank you This is a migrated post! Originally posted
VisualBasic Project into Zenon
Hello Everyone, I have an Application in VisualBasic (Visual Basic Project). I want to merge this with the existing VBA project of ZenOn. Could you please guide me through. Regards, Jyo This is a migrated post! Originally posted on 16.06.2014 by user
Multiple monitors in GRID in Zenon V7.11 on windows 8.1
Hi! I would like to create a 2x3 GRID with 6 monitors for a project. I have achieved part of success, which means I was able to create line display with the monitors (three vertically and two horizontally) but in grid layout it usually displays only one
Get data from aggregated archive
Hi support, :) Is that possible to get value from aggregated archive to internal variable? My application is I need to get aggregated archive value for mathematic calculation, my thought is get aggregated archive to store in internal variable and calculate
Metler Toledo Waage Serielle Verbindung (RS 232)
Hallo Zusammen, ist es möglich eine Waage, in meinem Fall von Metler Toledo mit Zenon über die RS 232 Schnittstelle zu Verbinden ? Die Waage hat nur eine RS 232 Schnittstelle sonst nichts. Ich weis es wäre möglich die Waage über RS 232 an ein Profinet
Unlocking the system as administrator
Hello. I have problem with unlocking system and I can't find answer in manual. I've found my problem at chater "User Administration" - "Operating during Runtime": -After entering a not existing user name the system is locked. This means, that no user
Read I/O from BECKHOFF PLC
Hello I am trying to read data from BECKHOFF PLC. Export a signal from TPY file (from Twincad) to Zenon, but it is still has no connection to the real PLC. From PLC side the signal is working properly. Hope somebody can give me a hand and explain what
Variable attributes
Hello I would like to ask, where I can find list of variable attributes as a " % abbreviation " ? For example %L means Identification. Thanks Jaro This is a migrated post! Originally posted on 11.06.2014 by user jaroslav_kral. Please be aware that information
"Bildname ändern" - Event?
Hallo, gibt es ein Event, das im VBA ausgelöst wird, wenn der Name eines Bildes im Editor geändert wird? Hintergrund: Zur besseren œbersichtlichkeit sind in den einzelnen Bildern Textfelder mit dem Bildnamen hinterlegt. Wenn jetzt der Bildname geändert
Switch limit active/inactive in Realtime
Hello. I want switch off some limits in runtime. For example, when some equipment stoped for weekend. As I understand, I can use "AlarmGroups", but I can't change group of limit in runtime. Can I change limit property "Active" for activate every limit
Unlocking in commands
Good Morning, we have defined command groups with several interlockins for each action and they are working fine. Now, our client wants these interlockings not to block the commands, only to inform. I have tried with the "unlocking" button but it does
Problem with SQL Driver
Hello, I've got a problem. I'm using SQL Server to change value of variable in zenon. I created 2 tables zRECEIVE and zSEND, configured sql driver and add the same variables name in driver and in my project. After I insert data in zRECEIVE table zenon
Re: Zenon 7.10: Application error during installation
Hello, I have the same problem when i want to install zenon editor of energy edition on win7 32bit ultimate. Please view attached image. This is a migrated post! Originally posted on 06.06.2014 by user milad2002b. Please be aware that information can
Anpassen der Symbolleisten im Editor
Hallo, gibt es eine Möglichkeit, die Symbolleisten im Editor anzupassen? Z.B einen Button einfügen, mit dem man einen häufig auszuführenden Wizard startet. Gruß This is a migrated post! Originally posted on 10.06.2014 by user wenzm. Please be aware that
Acknowledge from VBA
Hello, I am sorry if my question is very simple. How can I Acknowledge a variable from VBA? Thanks This is a migrated post! Originally posted on 09.06.2014 by user jessica. Please be aware that information can be outdated.
symbol editor keyboard actions question
Hello support team. I want to report you some bug in symbol editor. Trouble is about using keyboard keys when mouse is pointed to one of perimeter node point of selected symbol element to change only size by node side. When symbol element or symbol is
Alarmgruppen und -klassen mit VBA auslesen
Guten Tag, ich möchte mit VBA die Alarmgruppen und -klassen vom Global-Projekt auslesen und für einen Import-Wizard als Combobox aufbereiten. Leider komme ich per VBA nicht auf die Alarmgruppen und -klassen Weiß jemand Rat ? btw.: ZenOn V7.00 Josef Vallant
What is my RT version?
Hello all I have a project in zenon 6:22 SP1. This project will be made to run on RT_6.22_SP1 or RT_6.50_SP0. I would like to know if it is possible through a VBA macro, write the value of a variable: v = 1 if RT = 6:22 v = 2 if RT = 6.50 Thanks in advance,
How to Change color of dynamic text element
Hi ! Im still kind of new to this zenon thing... Im trying to find a way to change the background color and text color of a dynamic text element through VBA. I've found out that its possible by setting limits and defining limit colors..but i find that
Allocations not working
Hi, we don't see why the source variable is not copied to the target variable. Is something wrong? Thank you This is a migrated post! Originally posted on 03.06.2014 by user knubla. Please be aware that information can be outdated.
IEC 61850 Error
Dear Support, In one of our projects we have Zenon running on server connecting to 1000 IED devices using IEC61850 protocol, time to time runtime is stopping and appearing one error "IEC61850 out of memory" see attached snapshot. This is a migrated post!
VSTA Editor lässt sich nicht mehr öffnen
Hallo, ich wollte den VSTA Editor für die Runtime neu öffnen. Nun habe ich das Problem, dass dieser sich nicht mehr öffnen lässt. Den zenon Editor und den PC habe ich schon neu gestartet. Der Prozess für den VSTA Editor startet sogar aber er öffnet sich
ArchivThread(): Hardware-E/A-Fehler
Hallo liebe Leute! Hatte heute folgende Fehlermeldung bei einer laufendenen Runtime auf einem Einzelplatz-Rechner. AchivThread():Ein Hardware-E/A-Fehler wurde während des Zugriffs auf C:\Projektxxxxxxxxxx\P2121027220000.ARX gemeldet. Nachdem ich diesen
Sicam 230
Hi, I have two AK1703 and two SICAM 230 devices on network. The first network consists of AK1703 and SICAM 230 that receive information from one group of relays via IEC61850. 2nd network consists of AK1703 and SICAM 230 that receive information from another
Substition von Variablen bei Bildumschaltung während der Runtime
Hallo, ich habe folgendes Problem: im Projekt sind mehrere Motoren vorhanden, deren Status ich mit einem Tastendruck aufrufen möchte, z.B. Drehzahl Da ich aber nicht für jeden Motor ein eigenes Bild erstellen möchte, würde ich gerne bei der Bildumschaltung
Pointer for variables.
hallo, I am quite a fresher to Zenon world. I started using it couple weeks earlier. If there was a thread running on this topic, please direct me there. Task: I need an output numerical display box to show the values for the respective variables. When
Determine if a limit is active and going to AML
Is there a way to show on a screen if a variables' limit active and going to the AML? For example if I have variable loop1.inHHA boolean in group1 with a Maximum limit set to go to AML and the function to do deactivate group1 has been called. Is there
zenAdminSrv startet nicht immer automatisch
Hallo zusammen, gibt es einen behebbaren Grund, weshalb bei einem bestimmten webclient der zenAdminsrv nur bei jedem zweiten Rechnerstart automatisch gestartet wird? - Ich habe aktuell ein windows7-Notebook, bei dem das einigermaßen zuverlässig der Fall
Skalierung der Y-Achse
Hallo zusammen, ich habe ein Bild vom Typ erweiterter Trend und möchte die Skalierung der Y-Achse flexibel gestalten. D.h. ich möchte z.b. ein bzw. zwei Eingabefelder haben, wo ich dann die Skalierung einstellen kann. Ist das möglich? Hat da vielleicht
Problem in Trend for IEC61850 data
Hi Experts, I have read few analog parameters through iec 61850 driver. I have configured them in historian with on change recording, but I am not getting any trnd on trend display.it shows blank or a straight line. I have also checked in archive, no
Zenon Opc On Dcom
Hello support, I have Zenon 6.51 installed and I need to configure OPC server, but i could not find zenon opc server on component services...dcom? how to install it? Thanks in advance This is a migrated post! Originally posted on 18.05.2014 by user yara.
Next Page