Variable Maximum over 1 day with time stamp of when the maximum was recorded
I have been asked to make an alarm list entry of a maximum value over 1 day from PLC variable with time stamp of when the maximum was recorded, so the user can look back at the last 30 alarms that will show the maximum value and time the value was recorded
ConnectionState variable
Hi! I'm using Zenon Energy Edition v7.6 with the IEC61850 !ConnectState Variable to detect communication error for ALM with a certain IED in my project. But the variable never goes to TCP_CONNECT_ FAILED when i disconnect the RJ45 cable from that IED
REMA Dynamic limit value text
Dear colleagues, I have REMA which contains error codes and messages. The back end PLC code with updates may receive new new error codes which won't be declared in Zenon yet. To handle unknown error codes I have activated "Default value" with Dynamic
2 Sollwerte mit Combielement setzen
Hallo, ist es möglich 2 Sollwerte über ein Combielement zu setzen? Folgendes Problem will ich lösen, nach möglichkeit ohne freie Programmierschnittstelle. Ich habe ein Heizlüftersymbol, wenn ich auf das Symbol klicke, öffnet sich die Steuerungsseite dazu.
General Interrogation Fail in 61850
Hello, I am working Zenon Energy version 7.20. Zenon communicates with many SEL relays using 61850 protocol. I want to use RCB, but I have problems when the RCB are activated by Zenon. If I use polling mode everything works well and the representation
Netzwerklizenzierung
Gibt es eine Möglichkeit eine Lizenz bzw. eine Seriennummer von einem Netzwerkserver in die Licence.ini eines lokalen Clientechners zu übertragen, ohne diese händisch zu kopieren/editieren? Folgendes Szenario: Wir haben eine Seriennummer unter welcher
Sub Project in Webserver Pro Lite
Hello Team. I have got a Web Server Pro Lite license 3 Clients. I have one main project and one sub project inside the main project. Neither of them are client projects. I have linked the sub project to my main project via screen switch and vice versa.
control 2 variables in graphic/pushbuton
hi i would like to know if it is posible in a graphic/pushbuton to control to variable at the same time for example a BOOL value and an analog variablestate of the button will be only the BOOL variable of course This is a migrated post! Originally posted
Ce 6.22 sp1
Dears,can you send me the CE Installation as it was a separate setup in version 6.22 sp1 ? EMAIL: Very thanks This is a migrated post! Originally posted on 10.10.2018 by user junzai1002. Please be aware that information can be outdated.
zenon CE 6.22 sp1
Dears,can you send me the CE Installation as it was a separate setup in version 6.22 sp1 ? EMAIL:978809376@qq.com Very thanks. This is a migrated post! Originally posted on 10.10.2018 by user junzai1002. Please be aware that information can be outda
Embed symbol checkbox.
Hi, I want to modify variables by zenon Logic, but cannot manage to check "Syb." checkbox in Straton. I'm getting message "The variable is currently locked". Any idea what should i do? This is a migrated post! Originally posted on 09.10.2018 by user www121212.
Operator Extended Trend not displaying on RT computer
Hi All, I set up an Extendend Trend screen with the Standard Scada 1920 template. I configured the screen switch function to read 23 tags from 2 different Historian Archives, edited some curves names... It works well on Editor Laptop, when i switch the
Integrate/Connect/Link HMI graphic with PLC instructions
Hi COPA DATA I want to ask regarding on how I can link/connect/integrate my PLC instructions with HMI that I created in Zenon. Currently, I am using WAGO 750-8202, DI card (part number: 750-1405) and DO card (part number: 750-1504). I read the manual
.rdl file (Report Viewer) shall open in Report Builder
Hi, I've Zenon 8.0 and want to open a .rdl file within Report Builder 3.0 (additional installed) for editing. But all the time when I try to open the .rdl from within Zenon, Visual Studio opens. Is there a way to define that Report Builder shall open
Build Installation Errors
Dear Team , Most of the cases we are facing issue in installation of new builds, screenshots are attached. Can any one share links for Zenon 7.00 build 32 and Zenon 7.11 build 45643. Warm Regards Srikanth G This is a migrated post! Originally posted on
Straton Reading Wrong System Time
Hi Guys I am using get curdatetime block in straton to read the system time(which i use for a logic) in the Server, Now the problem is the block is reading the UTC time but i need UTC+5.30 (my system time is already UTC+5.30 only). The same logic is reading
Redundant Ip address changeover event in CEL
Hello Team, In energy drivers wherever secondary IP address is possible, I want to generate an event or Alarm whenever a changeover happens from primary to secondary IP. I want to achieve this without using SNMP. Whether I can get an event from my IEC60870
Archive data in azure
[LEFT] [/FONT] In one of our projects, we have successfully, exported the archive data from Zenon to SQL Cloud.[/FONT] But we are getting TTL Expired exception error. Because of that messages are moving to the deadletter queue.[/FONT] [/FONT] 1) Is there
How to use gateway in Zenon Energy
Hello everyone, I have a question. I usually use Sicam 230 and I use the section "Gateway" under "Variable" menu for example to translate a SinglePoint 61850 stVal status variable to a IEC 60870-5-104 variable M_SP_TA_1 (ASDU 2: Single Point with timetag).
Get User Group Level Number
How can I get User group Level Number Not User Group Name ? I am getting User group Level name from get_dynproperties("UserGroupLevel") in C#, But what I want is User Group Level Number. or I there any way I can find out User group Level Number from UserGroupLevel0,UserGroupLevel1,UserGroupLevel2
how to share variable from external PLC to other PLCs in the network using Zenon SCADA
I am reading wind data from Delta PLC using Modbus TCP/IP. I want to send this wind data to other PLC Slaves(Delta) in the network using Zenon SCADA. Is this possible without using Zenon Logic? Thanks Lingelethu Dyasana. This is a migrated post! Originally
Change BOOL state with PopUp window
Hi guys, I only begin to learn Zenon and at the moment I need to change with PopUp window. I have some Switch and I want after click on them see PopUp with buttons (Turn on/turn off) and after click on this button change switch state. I create screen
Need some help for two simple things
Hi, I inherited a Zenon project and have to add a new PLC and some new functionality to it. System is Zenon Supervizor Version 7.60 SP0 Build39532, PLC is Festo CPX-CEC-C1-V3 (Codesys 3), so I'm using the Codesys driver (3S v3 driver for PLC handler).
SMTP without POP.
Hello all, At one of our clients I can't get Zenon 7.60 to send e-mails by SMTP. The client does not have a POP server, only a SMTP server. Sending e-mails by SMTP with Powershell works fine. The client gave me the following settings: SMTP: bla.blabla.nl
Levels/Layers in Zenon
Hello Team, Is it possible to activate and deactivate layers/levels in runtime? That is, suppose I have made a screen using different levels. When I deactivate/invisible a level the graphics in that level disappears from the editor, and when I activate/visible
Static text box to blink
Hi everyone, I am very new to Zenon product and I am barely know about the configuration and so on. Currently I am developing one HMI panel which later to be integrate with WAGO PLC. I am using Zenon Energy version. Question is: 1) How I can make my static
Status bits actions in reaction matrix do not enter entries into CEL/AML
Hello Team, I have configured a reaction matrix to execute a function and to create an entry in CEL/AML whenever the status bit 'off' changes. Although the status bit is changing, neither the function nor the CEL/AML entry gets executed. This same I have
Alams/ Events Deletion
Hi, Support. Is it possible to delete Alarm & event of a specific (absolute) time period ? or few specific alarm or event ? If yes.. Please explain the same. Thanks in advance. This is a migrated post! Originally posted on 21.09.2018 by user azami. Please
How to change mouse coursor - Runtime
Hi I have a question about mouse cursor in the Runtime. Is any procedure how is possible to change mouse cursor for screen switch or commands as well (for example from "hand" to "arrow")? Thank you Stan This is a migrated post! Originally posted on 26.09.2018
Variablen, Bilder, Funktionen etc. in Gruppen (Ordner)
Es wäre echt super, wenn es wie bei WinCC die Möglichkeit geben würde Variablen, Bilder, Funktionen, etc. in Gruppen (Ordner) unterteilen zu können, damit man das Projekt übersichtlicher gestalten kann. This is a migrated post! Originally posted on 20.09.2018
Historian Read Back
Hi, Please help me on this issue: In the case with architecture of using Historian Computer working independently with Server Computer, is there anyway to store database in both Server Computer and Historian Computer? As I see Server Computer will save
Reg: Unable to restore backup in particular laptop
Hi Team, Good Day. When I tried to restore in a specific laptop this is not restoring. Below is the error image i am getting. Please support Thanks regards sarav This is a migrated post! Originally posted on 19.09.2018 by user saravanan1985. Please be
Multi-binary Reaction matrix problem
Dear Team, Zenon Version 7.50 Build 49034 We are receiving Alarms from OEM machine using variable UDINT datatype Example: - Alarms are triggered bit wise (1, 16, 17, 19, 20) then we have written VB script for receiving it and moving to individual Internal
Recipe not loaded properly
Hello, I have a problem with straton: I want to save+load some values using the integrated recipe manager. However it appears that some values are not saved/loaded properly ! The same problem appears by saving or reloading values to/from the recipe. Here
WMI Treiber
Moin, gibt es eine Möglichkeit / Treiber eine Schnittstelle zur Windows Management Instrumentation (WMI) zu schaffen? Wir haben ein Netzwerk, in dem nur einzelne MAC-Adressen freigegeben sind. Wir würden nun gerne eine Meldung in der Ereignisliste oder
I want a from date time and to date time of report filter in my rdl file
Dear all, I'm using zenon 7.50 with build 49034, i want From DATE TIME and TO DATE TIME of time filter to my rdl file , i'm linking my report function to absolute time filter with propose current date and time from the above picture if i put from and
zenOn Logic - speed-up download?
Hi guys, I would like to know if there is a way to speed-up the program code download from zenOn Logic to the target. Right now on my development PC with an application code APPLI.XTI / STRATONRT.COD from about 1.2MB, it takes about 40s to download to
Variable deactivation and alarm deactivation from Runtime
Hello Team, Is it possible to deactivate a variable(or many) and alarm from the runtime. ? That is the variable deactivated from the Runtime should not be ever polled until I activate it back and the Alarm deactivated for any variable should not show
Checking communication presence with secondary IP address(device) while primary communication is established
Hello team, In many of the drivers, we have option to enter a secondary IP address/ redundant IP address. In my case IEC 60870 client driver. My requirement is, while my SCADA is communicating with the primary IP address in the driver, I want to check
Archive values after communication loss
Hello Team, Once communication with the PLC is lost, my archive logs the last updated data. I want to log '0' in each tag once communication is lost. Please suggest. This is a migrated post! Originally posted on 08.09.2018 by user joelprasad. Please be