Recent Topics
S71200 error
Hi, I have created a sample project in TIA V13 and tried to communicate with Zenon 8.0 but no communication. Attached the diag viewer This is a migrated post! Originally posted on 13.09.2018 by user sandeep2018. Please be aware that information can be
Iec60870 104 slave driver process gateway
Hello Team, I am using IEC60870 104 fieldbus in zenon logic as slave as a process gateway. I have added certain no. of IEC61850 double point information to the gateway. Now in the client side of the gateway I am getting readings like shown below: For
Edit formula of MATH Variables
Dear Support Please suggest and provide a sample code on how to edit the formula section of the Math variables. I want to add Variable, select Formula definition and add actual Formula by vba. Best Regards Sarfaraz This is a migrated post! Originally
Communication with AB PLC
Hi, i have three PLC's to be interfaced with Zenon Copadata. Please advice the best option for this 1.Allen Bradley-Compact Logix L35E 2.Allen Bradley-SLC 5/04 3.Allen Bradley-Micrologix 1500 Regards Sandeep This is a migrated post! Originally posted
SNMP Driver memory issue
Hello Support, I have one doubt for SNMP driver, How many IED we can add in single SNMP driver ? A large memory (CPU & memory) used by this driver. I want to minimize it. For Example, I have 16 switch, so how many driver i have to create so that system
Comtrade viewer issue
Hello Team, Even after licensing using energy license it shows this message'No energy edition license found' on the comtrade viewer. I have attached the screenshot. Please suggest This is a migrated post! Originally posted on 08.08.2018 by user joelprasad.
Funktion ruft Script nicht auf
Hallo, Wir haben VBA Scripte die Werte in eine Text-Datei schreiben. Diese Scripte werden durch eine Funktion aufgerufen. Die Funktion wiederum wird durch den Grenzwert 1 der Variabel aufgerufen. Mit ein paar Anpassungen habe ich das als Vorlage für ein
Zenon Remote Runtime Driver Issue
Dear Team, i have been trying to communicate to low version to High version and vice-versa. Having more problem in Zenon 7.50 ,7.60, 8 version After multiple trails then communication is being establishing. Provide solution as soon as possible Regards
zenDBSrv.exe is not responding
I have been using zenon versions 7.50 and 7.60 . facing issue in standard of version . I have been forcibly stopping zenDBSrv.exe and then my version is being standard kindly provide me solution as soon as possible Regards Diana John This is a migrated
Zenon New Build Numbers 7.50, 7.60
Dear Team, I have been using Zenon from long time. Its great to see support team is additional helping all the engineers using forum. I wish to know the latest Build number of Zenon Versions 7.50 and 7.60 . Kindly share me the link as soon as possible
Error message popup from windows everytime I open and close Zenon energy runtime
Hello Team, I am facing an error every time I open and close Zenon Runtime. Although it does not affect the functionality of the runtime. In the beginning when the error comes, I close the dialog box and the runtime works perfectly. Any suggestions why
Screen selection
Hi, I am new to zenon scada and trying to learn about the software. I created two screens ie Main screen and Menu bar with different frame but when I run application only main screen displays and Menu bar not visible. How can i combine this ? Regards
Shift Management: Unexpected crash on IShifts.GetItem
Hi guys, I'm having big troubles with shift management. In my app I have these few lines that reads informations from the Calendar in order to keep track of "today" shifts. _shiftsToday = shiftFilter.GetShifts();
if (_shiftsToday != null)
{
IShift
Communication with IEC 61850 edition 1 and edition 2 simultaneously
Hello team, While communicating with IED Devices of both IEC 61850 Edition 1 and edition 2 simultaneously, is there any prerequisites/necessary settings that needs to be taken care off? Can both the Edition devices communicate with the same IEC 61850
Zenon to Siemens PLC Tag writing delay
Hello, In my project i have used Siemens CPU 319 and it is connected with Zenon Supervisor. With PLC i have connected many devices via profinet and Zenon supervisor too. Total no of PLC tags is 4500. Here i have recipe (RGM) and datalogging to MSSQL using
Copy Extended Trend between clients
Hi Support, I created filters in my extended trends screen (see picture attached, for example: G3_YUNCAN) in my client computer. Now i want to copy these filters to another client computer (I donÂ't want do it again, because there are a lot of filters),
Lot filter interaction
Dear all, I am trying to perform a combination of a lot filter, trend and report viewer in the same screen (currently using 7.20 version) They work well individually but I do not know how to get the name of the selected lot in the filter. Once I get it
Service - memory leak
Hello, Our service reads some data from archive each minute (using Thread). But when this service is running, Runtime memory increases continuously. Could someone help me to detect, what is wrong with this part of code: public class ServiceExtension :
VBA funktioniert nicht im WebClient
Hallo, wir haben das Probelm, dass in unserem Webclient kein VBA Code ausgeführt wird. Wir nutzen Zenon 8 (64Bit) auf einem WindowsServer 2016 Standard und zur Anzeige des WebClient den WebClientStarter auf Windows 10 (64Bit) PC's. In der zenon6.ini ist
zenAdminSrv & zenLogSrv not starting due to Error 1053
Hi, I have Zenon 7.10 Supervisory version installed at a EWS in Kuwait site. Till date, Zenon was working smoothly but I installed ABB PCM600 software and then Zenon services seems to be stopped working. So I uninstalled all the ABB PCM600 software and
Automatischen Start von "Project Configuration Wizard" abschalten
Hallo zusammen! Ich möchte gerne den automatischen Start des "Project Configuration Wizard" nach dem Anlegen eines neuen Projektes im Editor abschalten. Hat jemand eine Idee wie das zu bewerkstelligen ist? Das Addin "AddinProjectWizardWinforms" möchte
TIA Variablen Exporter
Hallo Zusammen, Ich wollte mit Hilfe des TIAProjectExporter einen Variablenexport machen. Nun kommt beim Start der .exe immer die Meldung "Warning: Initialization failed" obwohl ich die exe mit Adminrechte ausführe. Wenn ich eine .ap13 auswähle kommt
61850 remote server or client
I have v7.6 Energy Edition communicating to 61850 IED servers. I need to set up remote 61850 access sort of like a process gateway. Are there any papers or KB posts regarding this? Does it require a second driver instance? Thanks This is a migrated post!
Zenon 7.60 switch throw an dialog in runtime
Dear gents! I have migrated my project from Zenon 7.20 to 7.60 and faced with a problem. When I run it on my development PC and when any of switch buttons pressed (Start/Stop/Reset/etc.) the system throw up the dialog to modify spontaneous value, in the
Automatisches Logout für bestimmte Benutzer
Hallo, ich habe mal eine Frage zu dem automatisches Logout nach Ablauf einer einstellbaren Inaktivitätszeit. Wir haben von einem Kunden die Aufgabe erhalten, dass sich alle Benutzer automatisch ausloggen. Lediglich für einen benutzer soll diese Funktionalität
Alternativen zu Combi-Elementen, Störungen quittieren bei Fromen
Hallo zusammen, da in der HTML5-Lösung von Zenon keine Combi-Elemente im Browser dargestellt werden, bin ich auf der Suche nach Alternativlösungen. Mit Formen (Kreisen, Rechteck, Polygon, Linien) lassen sich Symbole erstellen, die die gewünschten Funktionalitäten
Read IEC61850 Command AddCause after select write successful
I am currently facing an issue with the IEC61850 SBO command AddCause. I read the command fail AddCause by using this command info variable: */Oper.AddCause The variable works fine if the failed condition already exist before select. However, if the failed
Supported OS
Which all windows OS is Zenon Compatible? Is it compatible on windows server 2016? This is a migrated post! Originally posted on 27.07.2017 by user joelprasad. Please be aware that information can be outdated.
How to clear cache values after connection loss
Hi Guys I have a Scenario where I am facing trouble I have many Relays and calculating the Total Current by adding all the current values of the relay. If suddenly the communication of one relay is lost then the value (that was updated before communication
SQL-Export vin Archiven
Hallo, ich möchte unsere Archivwerte in eine SQL Datenbank schreiben. Hier haben sich jetzt 2 Fragen ergeben: 1. Kann man die SQL Datenbank welche Zenon bei der Installation mit installiert dafü verwenden? 2. Bei meinen Archiven ist die Option speichern
Import Screens
Hello, I have a problem with screens XML import in Zenon [Zenon Editor Version 7.50 SP0 Build25796 32Bit]. I want to export all screens, update the data regarding screens in Excel and then import it back. I succeeded to export XML and then to open the
Autmatic write command at the every new start of Modbus TCP session
Hello! I am trying to communicate with diesel controller via Modbus TCP from Zenon EE 6.22 SP1 Build 0. Controller type is ComAp IG NTC BB. At the start of every new Modbus TCP session there must be (multiple) write command to ceratin register(s) in diesel
Create Custom Driver
I want to create a custom driver to connect the Zenon PC to another PC with TCP/IP via ethernet. The driver is created with zenDrvHelper and edited in C++ Visual Studio. The problem is there isn't any manual book to create custom driver, especially TCP/IP
Proble with Bachmann M1 Protocol
Hi Guys I have a problem while extracting signals from Bachmann protocol. I am having 10 wind turbines, and I need to communicate with all of them.I added the Bachmann Driver and configured all the turbines inside it. If I Extract signal from one turbine,
Success stories in tire manufacturing plant
Hi , I wonder if there are any success stories in the field of "Tire Manufacturing" , in Automotive industry . Please let me know if there is any, Thanks . This is a migrated post! Originally posted on 07.08.2017 by user parisa,taebi. Please be aware
DNP3 communication
Hello, I have question about DNP3_TG driver. I want to create communication with RTU (DNP3 Slave) via GPRS TCP/IP. But wap ip address of the outstation is not static. The case is that the slave initiates a session but the master does the polling so Zenon
Delta PLC AS300
Dear reader What driver is needed to integrate a Delta AS300 PLC into the Zenon SCADA? The Delta AS300 utilises Ethernet IP. Thank you kindly This is a migrated post! Originally posted on 11.08.2017 by user PaulRudolph. Please be aware that information
Zenon 7.60 Agoust Build
Hello, we have Zenon 7.60 on our systems (Build is 37399). Unfortunatly we open a defect for filters in editor (when you open the ... button and you apply a filter the second time you open the same button but variable is out of the filter the editor seem
Farben der Alarm- klassen - bereiche zur Runtime auslesen
Hallo, ich suche eine Möglichkeit die Farben der Alarmklassen sowie Alarmbereiche zur Runtime auszulesen. This is a migrated post! Originally posted on 09.08.2017 by user fundsWB. Please be aware that information can be outdated.
More Tags in Historian - will make runtime slow
Hi Team, I have Central monitoring system (CMS) & 4 plants (projects) integrated to it and each project has 3000 tags of event/alarm data that need to be archived. If I add all those tags, Runtime in CMS response slow. Can you guide for a solution? thanks