Recent Topics
Simulation IEC 104 address
Is it possible somehow to simulate IEC 104 address in zenon 6.22 SP1 in order to test some variable in run time environment This is a migrated post! Originally posted on 28.08.2011 by user kirca. Please be aware that information can be outdated.
How to set update time and threshold for measurment variable in IEC 104
How can I set update time and threshold of the measurement variable (example current) in zenon 6.22 SP1 I m using IEC 61870 104 driver for connection of IED an zenon 6.22 SP1 When I start run time version the current is represent correct, but when I change
Get milliseconds information from CelItem
Hello all, Does anyone know how to get the milliseconds information from a CelItem object? I'm getting the user interaction to the "events list" through the "CelListSelectionChanged(ByVal obItem As ICelItem)" callback. It works fine. But I can't find
Print from Vipa CE
Hi, I have a Zenon 6.22 CE application running on a Vipa Touchpanel TP608. I would like to send data to a printer such as: "Batch XXX Start Time:" "Fault: XXX" "Batch XXX Complete Time:" Line by line. Is this possible? If so how can I implement this?
Variabele inerhalb eines Textelementes einbinden
Hallo, ich habe folgende Herausforderung. An meiner MA gibt es Stationen die mehmals an einer Maschine verbaut werden. Jetzt möchte ich nicht für jede Station eine extra Seite erstellen sondern die Variablen über unterschiedliche Bildaufrufe umschalten.
Error while loading the VSTA editor-addin
Hi, I've recently installed Zenon 6.51 Editor+Runtime on a Win7 PC. However, i get the error that the VSTA editor-addin caused the editor to crash (see attached) The Win7 PC has VS2008SP1 installed. I assume this somehow caused the issue? Anyone else
Print data from extended trend and reportgenerator in one report
Hi, is it possible to generate a report in pdf format which contains data from an extended trend picture and data from the report generator? I need a report with several pages: page 1: Texts form the current process (variables, static texts) page 2: contains
Makro für aktuellen Focus
Hi, bin gerade an einer Umstellung von Zenon Version 5.50 auf 6.51und suche nach einer Möglichkeit den aktuellen Focus der Runtime auf eine beliebige Schablone bzw. ein beliebiges Bild via VBA Makro zu ermitteln, ohne die gesamte Bilder-Bibliothek mit
Showing Archived data
Dear Support, I am trying to show the archived data on the HMI display on the numerical elements rather than in the reports. My aim is to generate a reading on specific time interval for energy, in three intervals. Each interval is of 6 hours. At the
Printer Selection
I have two printer one for alarms printing (dot-matrix) and other for report printing(LaserJet) . How I can select both printers in runtime. This is a migrated post! Originally posted on 13.08.2011 by user tanveerali. Please be aware that information
how to combine three different projects
I have 3 projects back up. I like to combine it in one project and during runtime I will switch to any project what I need. is it possible with zenon 6.51. This is a migrated post! Originally posted on 13.08.2011 by user tanveerali. Please be aware that
zenon crashed during the send of SMS et voice message..
Recently, our zenon Run-Time project is sometime crashed when a function of the send of SMS and voice message is started. ZenOn succeeds to send several SMS before its crash. But normally when we do the tests after the restart of Windows, everything works
Printing Report
Dear Support, I have 140 lines in my report and after I set the printing area it displays all the lines on the same page and that makes my report unreadable. Is there any option through which I can show only about 40 lines per page, or while setting the
reset of Drag indicator
Is there any way to reset the Drag Indicator (min/max) of Universal slider in Runtime manually? Currently It has Auto reset function and will be reset after definite time. How it will be reset if I do not activate auto reset function? thanks This is a
Reports
Dear Support, How can i save the reports in a format so that they can be accessed in any machine not having zenon. Saving them in a .pdf format is perferable. This is a migrated post! Originally posted on 10.08.2011 by user talal.mubarak. Please be aware
Priamry and Secondary Server configuration
Dear Support, I am trying to configure Primary and secondary servers can you guide to the proper procedure to do so. Secondly I have 5 different projects and I want to link them all in a single project so that during runtime all of them are available
Werte aus der Alpha-Archivdatei werden nicht angezeigt
Hallo, in meinem Projekt gibt es ein Archiv für Chargenprotokolle. Dies wird täglich gespeichert und in ein Ordner ausgelagert. Seit dem ich das Projekt zu einem Netzwerkprojekt (Server und Standby-Server) gemacht habe, kann ich mir die Chargenprotokolle
Archive report
Hi Could you give me some advise with my archive report? It work normally before but on 2 day, some problem happen with my archive that time is repeat twice, and after that automatic come back normally. Please see picture to more detailed. Brgds. This
OPC-server Kepware and Zenon 6.51
Hello, I have some problems with communication of Zenon and Kepware on different computers. I have the first PC with OPC-server and the second PC with Zenon. I made test channel with simulator driver in Kepware. In Zenon I made test variable with OPC
Probleme mit dem SMS versenden
Hallo, nach vielen Problemen mit dem Message Control bin ich nun soweit das ein Eintrag in die msgctrl.txt erfolgt. Beim ersten Alarm kommt der Eintrag das die Nachricht in den Ausgang gelegt wurde. Es kommt aber keine SMS an. Die Nummer ist aber die
straton for Brodersen RTU
Need your help regarding how to install Straton Runtime on Brodersen RTU32. Thanks! This is a migrated post! Originally posted on 07.08.2011 by user hoscillada. Please be aware that information can be outdated.
Elements.Type immer 0 ??
Hallo, Ich möchte alle Elemente des Typs "dynamischer Text" und "dynamischer zahlenwert" über VSTA die Hintergrundfarbe ändern. Aber bei der Abfrage des Type aller Elemente im Bild bekomme ich immer als ergebnis "0". Wenn ich aber den Elementname abfrage,
Send Value to hardware
hi! how can i send value to hardware in vba with out using function send value to hardware or command thisProject.Variables.Item("xxxx").Value = 0 is not usefull in this case? This is a migrated post! Originally posted on 04.08.2011 by user anahita. Please
VBA Wizard don't work properly with multiple Element of Type 130
Hello support! We want to change some values inside the Dynproperties of some elements of type 130 (i.e the $_xxxx propetries). To do this we have followed the example of the COPA DATA Wizard 'frmSymbol'. We apply the procedure to many (i.e. more than
Bit Alarmierung
Hallo, ich bekomme von der Steuerung 10x 32bit Variablen. Jedes Bit dieser repräsentiert einen Alarm. Also ein paralleles Alarmsystem. Gibt es eine einfachere Möglichkeit diese Bits alarmässig auszuwerten als 320 boolsche Variablen anzulegen und zu verarbeiten?
RemoteTransport
Hallo, in einem Projekt möchte ich gern die Pfade für den RemoteTransport über VBA ändern, da sich die Pfade tagesabhängig ändern. In der VBA Hilfe (vom 07.11.2007) kann ich nichts darüber finden. Finde auch leider keine aktuellere VBA Hilfedatei. œber
Program access to structure datatype variables
Guten Tag! We have a lot of structure datatype variables in our projects and wish to use their Identification field in our VBA or C# programs. When we tryed to access this variables by .Variables().Items(StructureTypeVarName) we received "null" as result.
Some variable's properties to be filled with the archived value of a variable in a report sheet
Hi, In a report sheet we need to have a column of the value of an archived variable. Meanwhile we need the next columns to be filled with “unit†and the “limit text†of this archived variable. I mean when an archived value is logged in the report
RGMRecipeVars sortieren
Hallo zusammen, wir möchten die Variablen der Rezeptgruppen durch VBA sortieren. Ist das möglich? Grüße rln This is a migrated post! Originally posted on 28.07.2011 by user rln. Please be aware that information can be outdated.
"WriteSync" und "PWLevel"
Hallo zusammen, wir versuchen durch einen Wizard die Eigenschaften „WriteSync“ und „PWLevel“ der RGMRezepte zu bearbeiten. Ich habe in der Hilfe gelesen, dass beide Eigenschaften nur zum Lesen vorhanden sind. Es hat aber trotzdem bei uns vorher
online printing
i am using dot matrix printer to print alarms online. i need to print variable name and time but it only print identification and time . plz guide me This is a migrated post! Originally posted on 25.07.2011 by user tanveerali. Please be aware that information
Deployment of ZenOn Application
Hi, how can I deploy a application onto a computer on which the ZenOn Editor isn' t installed? I would like to install only ZenOn Runtime + ZenOn Application on the PC. Normaly I installed ZenOn Editor first, than load application into Editor workspace
MODBUS RTU convertor
Hi I have an SEL ralay SEL-587Z having one serial port for Modbus RTU communiation , will i have to use a convertor to convert to modbus TCP and then retrieve the info on scada. Can any one suggest the name of a good convertor for this purpose. my all
Link between an INT PLC variable and a STRING interne variable?
Hi! I have a question about STRING variables... In fact, my program ZenOn reads directly an INT variable from a PLC (who controls a machine). Its value represents different status of the machine. For example, value 0 represents “System OK†, value
Standard Recipe - Retrieve name
Hi. It is possible to retrieve the name of the current recipe to a string variable? This is a migrated post! Originally posted on 21.07.2011 by user marduv. Please be aware that information can be outdated.
create project
when i restore project or make new project error window appear on screen .screen shot is attached This is a migrated post! Originally posted on 20.07.2011 by user tanveerali. Please be aware that information can be outdated.
WPF-Element konfigurieren
Hallo, habe heute etwas mit den Bsp-WPF-Elementen von der Copadata-Website herumprobiert. Laut der Dokumentation (Pkt. 5.1.1) sollen in den WPF-Elementen unter Eigenschaften einige Spalten sein, in denen man das WPF-Element konfigurieren kann. Bei mir
Keine Projektsicherung
Hallo Gemeinde, nachdem ich ein V5.5 Projekt importiert habe, möchte ich sofort eine Projektsicherung erstellen. Leider mekert hier der Editor V6.51, DAS PROJEKT EXISTIERT NICHT! Das gleiche passiert auch nachdem die Runtime-Dateien erzeugt worden sind.
Showing BMP file
Dear Sir, I want show the BMP file from Folder to Zenon Screen.. How to Show the BMP file.. Those Files are not fix its change so how to show the BMP file.. Thanks This is a migrated post! Originally posted on 18.07.2011 by user dhiraj. Please be aware
Texte Alarmbereich
Hallo, die Bezeichnung des Alarmbereichs wird bei der Ausgabe in der Alarmzeile oder Alarmliste nicht übersetzt. Gibt es eine Lösung dafür? 6.50 SP3 Gruß Jürgen Berger This is a migrated post! Originally posted on 15.07.2011 by user hicom. Please be aware
Next Page