Über C# Zenon steuern
Hallo, wie kann ich von C# über die Library "zenon programming interface library" auf die Zenon Runtime zugreifen. Ich möchte über ein Konsolenprogramm (nicht VSTA) überprüfen ob eine ZenonApplikation läuft und Zenon Funktionen ausführen. œber eine kleinen
Can not create new project.
Hi, I am having a weird problem right now. I tried to create new project but failed. Even after creating new workspace, I can not create new project. Please see attached images. P.S.: I compressed my C: drive after installing Zenon. Can this cause any
STRATON controling Modbus TCP slave bus controller with IO's
Hello, I have the problem with implementation of Modbus TCP communication. General: 1. STRATON system has to controm Modbus TCP slave from B&R which consists of Madbus TCP slave bus controller and some IO's 2. it is generated XML file with slave configuration
VBA unter XP - Embeddet
Hallo, kann mir jemand weiterhelfen. habe eine ZenOn RT auf einem Embeddet XP - Rechner laufen. In meinem Projekt habe teile in VBA geschrieben. Dabei rufe ich folgende Befehle auf RTrim, Format etc. wenn ich nun das Projekt laufen lasse kommt folgender
version problem
hi, sorry to bother you. I just have a problem and i wish you can help me. an error message says "the file templates.cmp has version 5.50 sp7 - but the project has version 5.21 sp2" and the list goes on variables.cmp scripts.cmp templates.cmp functions.cmp
Individueller Archiv Export
Hallo, zenon 6.51, Windows 7 Ich exportiere via Zeitsteuerung täglich, kurz nach Mitternacht, die Daten des Vortages, als .txt-Datei. Soweit so gut. Aber, Kundenwünsche: - Dateien sollen gleich als .csv-Dateien abgespeichert werden. - Dateiname soll das
IEC 61850 disturbance file extraction
Hi How we can extract the DR files from IEC 61850 relay. Can you advice please... This is a migrated post! Originally posted on 25.11.2011 by user ansab.tp. Please be aware that information can be outdated.
Problem with Message Control
Hello, We are experiencing a problem with the Message Control on ZenOn 6.51 SP0 Build 5 Runtime. The host station uses Windows XP. When the Message Control is active, the whole application crashs when the system is trying to send SMS or phone calls, even
Wibu Key im Netzwerk
Hat jemand Zenon Version 6.22 in Verbindung mit einem Wibu-Key Server am Laufen? WkSvLin wurde unter Debian 6.03, Kernel 2.6.32, mit dem Paket „wkrt-lin_6.0.501_i386.deb“ installiert und funktioniert soweit auch wunderbar, d.h. mit WS-CAD, welches
Picture migration to fit widescreen monitor
About two years ago, I implemented a visualization solution for a client using zenOn 6.22. The SCADA system consists of a main PC workstation, and a touchpanel running WinCE. Both devices display the same pictures, the touchpanel scaling down the pictures
Use variable in Substitution.
Hi All, I want to use a a variable in Target field of Substitution in linked rule of a symbol. Is it possible? e.g, Source is: *1 and Target field gets number value from a variable say, count. So Target Field should be: {count}. I tried and failed. Is
wo finde ich die Editor-Hilfe?
Guten Tag, gerade eben habe ich im Editor der Version 6.50 die Hilfe aufgerufen, habe ein Thema eingegeben und mir den Treffer angeschaut. Dieser verweist mich dann an die "Hilfe zum Editor, Abschnitt xyz". Da ich diesen Abschnitt nicht öffnen kann, frage
How To Access PEW simatic s7
Hallo, möchte auf peripheren eingänge lesend zugreifen, geht das? der Variablenimport findet sie nicht?! von hand als normalen eingang hinzugefügt und offest eingestellt bringt fehler, rotes kästchen gibts da eine möglichkeit? gruss This is a migrated
How To Access PEW simatic s7
Hallo, möchte auf peripheren eingänge lesend zugreifen, geht das? der Variablenimport findet sie nicht?! von hand als normalen eingang hinzugefügt und offest eingestellt bringt fehler, rotes kästchen gibts da eine möglichkeit? gruss This is a migrated
SPA Driver
Is ZenOn Support SPA protocol? This is a migrated post! Originally posted on 11.11.2011 by user ansab.tp. Please be aware that information can be outdated.
OPC Server Facility
Is Zenon database can act as an OPC server to transfer data to upstream devices? This is a migrated post! Originally posted on 11.11.2011 by user sandeep.vp. Please be aware that information can be outdated.
Bit Toggle
Hi, I need to be able to toggle a bit on and off when another variable is equal to a specific value. i.e. when M1_Status = 2, M1_ToggleBit = 0,1,0,1,0.......... with a second interval between toggles. When M1_Status <>2, M1_ToggleBit = 0 I need this to
Project startup
I'm not sure this is the right section but ... I'd like to know if there is a rule on project startup between VBA sub Project_Active and script AUTOSTART and AUTOSTART_CLIENT. On my application look like if: on server AUTOSTART is executed after sub Project_Active
zenon 6.5 sp0 for windows 7 professional 64bit
i installed zenon 6.5 sp0 to pc with windows 7 professional 64bit. but when i checked the dcom configurations , zenon opc server is not available. any idea? This is a migrated post! Originally posted on 01.11.2011 by user hoscillada. Please be aware that
VBA macroses reference table
Hello. For example in ModuleElement i have VBA Sub named LeftClickUp_CombiElement. I need to know where it is used, or may be my project already have no links to it. Is there some solution to know what elements on what screens uses VBA macros with given
Step Position with IEC104
Hi I'm trying to monitor the TAP (Step) position of a transformer. The IEC104 address from the RTU is of message type T32 - M_ST_TB_1, which is also available in the Zenon IEC 104 driver. This message is transmitted in two parts i.e. 8 bit unsigned (Step
IEC 850 variable-time format
Hi, We import a variable from siemens relay via 61850 into the zenon 6.51 SP0 The variable type is time with name .../t[ST] and when it is imported in zenon, the variable data type is UTC TIME. In the runtime we just see the a numeric value of this variable.
VariableChange old value
Hello Im using VBA in Zenon 6.22. When I creates onlinevariables, and uses the VariableChange event. Is there any way to get the old value of the variable? So if a variable changes from 1 to 2, I would like to be able to read both "1" and 2 This is a
Button Press On Different Monitors
Hi, I use the same picture on different monitors, I need to determine which monitor the button press came from using VBA.:) This is a migrated post! Originally posted on 24.10.2011 by user allmendinger. Please be aware that information can be outdat
Multi monitor in grid 2x2
Hi, I need to have 4 monitors in project. Monitors are distributed in a grid 2x2. Is it possible ? Haw do i setup ? Best regards, This is a migrated post! Originally posted on 24.10.2011 by user brada. Please be aware that information can be outdate
Symbol rotieren lassen
Guten Tag, Ich habe ein Symbol für einen Lüfter erstellt. Die Rotorblätter sind als eingebettetes Symbol zusammengefasst, und das ganze Symbol ist quadratisch. Wenn meine boolsche Eingangsvariable jetzt TRUE wird, sollen sich die Rotorblätter in der Runtime
Modbus driver - detecting link or device failure
Hello! I have several devices connected via RS485 and Modbus RTU/TCP driver to Zenon EE. I would like to detect device failure or link failure. I went through all driver variables, but I could not find appopriate driver variable. Is there a driver variable
Benutzerverwaltung via Active Directory (Domainübergreifend)
Ich möchte in einen Zenon 6.51-Projekt die Benutzerverwaltung via Active Directory benutzen. Dazu wurden zwei Gruppen im AD angelegt die verschiedene Mitglieder haben. In Zenon habe ich eine Benutzergruppe mit identischem Namen angelegt. Die Runtime läuft
IEC-Protokoll - Originator-Adresse
Hallo Bei dem IEC 60870-5-104 Protokoll gibt es auch die Möglichkeit zu Unterscheiden von welcher Quelle Befehle an die SPS gesendet wurden. Dazu ist im IEC-Protokoll die Originator-Adresse vorgesehen. Nun meine Frage: Wie kann man die in Zenon einstellen??
Measurent Scale transformation Question
Hi I have temperature meter device with range -30 +60 Celsius degrees. RTU send values 0 on -30 degress and 32767 on +60 degress. Question is Value range in PLC What Signal area min - 0 What signal area max -32767 Value Adjustement linear Measuring values
GSM-Modem(s) und redundantes Projekt
Hallo, unser Leittechnik-Projekt soll erweitert werden. Zum Einen sollen zukünftig bestimmte Störmeldungen per SMS an die Bereitschaft gemeldet werden, und zum Anderen soll das System redundant ausgebaut werden. Jetzt hab ich ein Problem damit, mir vorzustellen,
Compatibility with Windows Server 2008 R2 64bits?
Recently we try to immigrate our ZenOn projet from Windows XP 32bits to Windows Server 2008 R2 64bits. But we met some problems, especially for Message Control function. After the installation of the voice message modem and the SMS modem under Windows
Trend und Erweiterter Trend
Hallo, ich habe in einem Bild eine Trenddarstellung einer Temperatur eingebaut. Parallel dazu habe ich auch einen Erweiterten Trend für die gleiche Temperatur in ein anderes Bild integriert (weil ich von dort die Daten nach einem Klick auf die Schaltfläche
dynamic menue
how can make the caption of a menu item in mainmenu dynamic? for example when value of one variable be 1 the text of the menu became "On" and when value of one variable be 1 the text of the menu became "Off" This is a migrated post! Originally posted
Sicherheitseinstellungen in IE8
Hallo, welche Sicherheitseinstellungen müssen im Internet Explorer 8 unter Windows 7 getroffen werden, damit beim Aufruf des webclients am Anfang nicht die Inhalte geblockt werden? (Ohne dass deswegen in der IT-Abteilung Panik ausbricht!) Vielen Dank
RGM - VBA - ".Save" / ".Read" - change recipe status
- New RGM: How is it possible to change the status of a recipe via VBA? (RGMRecipe.Status and the Dynprop are ReadOnly). The status can be changed for a recipe version using the dynproperty: VBA Code: Sub chng_status() Dim myRGMGrps As RGMRecipeGroups
how to change driver in runtime
hi! i wanna change the driver (such as IEC 101)of 400 variable to intern variable in runtime how can i do it? thanks alot This is a migrated post! Originally posted on 11.10.2011 by user victoria. Please be aware that information can be outdated.
EIB KNX communication
Hello, I try to implement a communication bewteen zenon and EIB/KNX network. I have 6.22 zenon version and I have the help document about the driver EibV2_32 included in Zenon 6.51. In 6.22, the driver is integrated but not the help about. In order to
Zeitsteuerung gesteuerte Scripts auf Server und Standbyserver gleichzeitig ausführbar?
Guten Tag! Ich habe in einem Testaufbau mit Zenon 6.51 versucht ein Zeitgesteuertes VBA Makro auf beiden Servern gleichzeitig laufen zu lassen. Leider wird das Zeitgesteuert ausgelöste VBA Makro am Standbyserver nur ausgeführt wenn die Server Runtime
Kontrollelemente einfügen
Hallo, Ich habe ein Problem mit einem Kontrollelement. Das soll mir in ein Bild rauf und runter Scrollen. Ich muss dann das Kontrollelement in dem zu scrollenden Bild aufrufen und dann in das Bild bringen, in dem das Element "stehen" soll. In dem Bild