8.20
Time in ETM is counting up when using specific configuration with time filter screen
Summary Time axis is auto-scrolling also with use-selected time interval for settings 1 day, 1 month, etc. Description Time axis is auto-scrolling also with use-selected time interval for settings 1 day, 1 month, etc. Issue Number: 217096 Fixed on ...
HTML Web Engine: Reaction matrix prevents trends from opening
Summary The screen switch function (SSF) is now successfully compiled when an unsupported rema type is detected. Upon detecting an unsupported rema type in a variable of a curve of an SSF to an ETM which is a gantt curve, this curve is now removed ...
AccessOPCUA: incorrect attribute value for ArrayDimensions
Summary AccessOPCUA ArrayDimension attribute for non-arrays coded as empty array Description AccessOPCUA ArrayDimension attribute for non-arrays coded as empty array Issue Number: 237597 Fixed on Date: 2.3.2021 Versions: 8.20 0 BUILD 81129
AccessOPCUA: The OPC UA server does not include its application instance certificate in the ServerCertificate field of the CreateSessionResponse resulting in a Beckhoff OPC UA client failing to connect
Summary AccessOPCUA - The OPC UA Server application instance certificate is not included in the CreateSessionResponse when the OPC UA client uses no security. This can cause some clients to refuse to connect. Description AccessOPCUA - The OPC UA ...
In the screen type Userlist" also deleted User groups are shown at the user (runtime / service engine)"
Summary Deleted user groups are marked with " del" (eg. "DeletedGroup (del)") in the user list (old dialog + user list screen) and the list of selected user groups in the user edit screen Fixed update of user edit screen Description Deleted user ...
Editor: Two screens with same file name can be opened once, after closing them and again attempting to open them nothing happens
Summary Two screens with same file name cannot be opened simultaneously Description Two screens with same file name cannot be opened simultaneously Issue Number: 237251 Fixed on Date: 23.2.2021 Versions: 8.20 0 BUILD 81129
S7TIA32: Variables cannot be imported from a TIA project which contains DALI modules
Summary Update AGLink40.DLL and AGLink40_x64.DLL to version 5.6.1.3 for debug and release. Description Update AGLink40.DLL and AGLink40_x64.DLL to version 5.6.1.3 for debug and release. Issue Number: 238695 Fixed on Date: 24.3.2021 Versions: 8.10 0 ...
GIS Import functionality - some previous fields are overwritten
Summary The properties of the imported Elements was not considered in the original implementation. The same is considered and compared against while importing the xml Description The properties of the imported Elements was not considered in the ...
T5BusExIec850m - Client - The driver always sends Cancel with value 0 on analog comands (APC)
Summary Cancel command for analog values doen't contain value Description Cancel command for analog values doen't contain value Issue Number: 239358 Fixed on Date: 31.3.2021 Versions: 8.20 0 BUILD 82266
if a button is getting interlocked by clicking on it, the whole screen is getting inoperable
Summary The mouse path LBDown->Lock->LBUp will be processed correctly . Description The mouse path LBDown->Lock->LBUp will be processed correctly . Issue Number: 239156 Fixed on Date: 25.3.2021 Versions: 8.20 0 BUILD 82266
VASS driver can not switch to simulation mode
Summary Standard driver configuration is not stored correctly Description Standard driver configuration is not stored correctly Information no workaround Issue Number: 238981 Fixed on Date: 22.3.2021 Versions: 8.20 0 BUILD 82266
T5BusProfNetIO: stratonrt closes unexpectedly when receiving an invalid ProfiNet DCP frame
Summary The zenon logic application using a ProfiNet IO Contoller fieldbus driver closes unexpectedly on receiving an invalid ProfiNet message. Description The zenon logic application using a ProfiNet IO Contoller fieldbus driver closes unexpectedly ...
double @-character in 'time change' corresponding CEL-Entry
Summary - Description - Information There is noworkaround to generate a different / correct CEL entry. Issue Number: 238610 Fixed on Date: 11.3.2021 Versions: 8.20 0 BUILD 82266
.IsHidden property and .Move Method do not work with ElementGroups
Summary IElement.Hide doesn't work for element groups Description IElement.Hide doesn't work for element groups Information Create a visibility variable or a position variable and act on their value in the addin. (not usable by the client as he uses ...
zenon Logic Runtime closes unexpectedly when starting a specific application
Summary zenon Logic Runtime no longer closes unexpectedly when it is configured an high amount of Report Control Blocks in the IEC 61850 Server + GOOSE fieldbus driver. Description zenon Logic Runtime no longer closes unexpectedly when it is ...
Security Vulnerabilities in all versions of the CodeMeter User Runtime software
Summary We were informed by our supplier Wibu-Systems about two severe and critical Security Issues within their product the "CodeMeter User Runtime" software. A new version 7.21a of the CodeMeter User Runtime software is available from Wibu Systems ...
System throws error when try to create new metering point with calculate relative value" checkbox Activated"
Summary ~ Description ~ Issue Number: 223876 Fixed on Date: 10.6.2021 Versions: 8.20 0 BUILD 84627 | zenon Analyzer 3.40 0 BUILD 87645
Deadlock after opening a screen with an interlocked combobox
Summary Sometimes runtime freezes when a screen containing a combobox element with interlocking is opened Description Sometimes runtime freezes when a screen containing a combobox element with interlocking is opened Issue Number: 241596 Fixed on ...
HTML Web Engine: System.NullReferenceException when using global symbol in combined element of a local symbol
Summary Global symbols in combi element states are now correctly compiled. Description Global symbols in combi element states are now correctly compiled. Issue Number: 241255 Fixed on Date: 9.6.2021 Versions: 8.20 0 BUILD 84627 | 8.10 0 BUILD 84784 | ...
AccessOPCUA: OPC UA process gateway closes unexpectedly under specific circumstances during reload of the service engine
Summary - Description - Issue Number: 240142 Fixed on Date: 2.6.2021 Versions: 8.20 0 BUILD 84627 | 8.10 0 BUILD 84784 | zenon Analyzer 3.40 0 BUILD 87645
Message Control - support TLS to enable use of Office 365 for e-mail sending
Summary Issue Number: 242427 Fixed on Date: 15.7.2021 Versions: 8.20 0 BUILD 86192
LON_32: Driver does not load the configuration file upon start of the runtime and value & status of the variables in not shown
Summary LON_32 drivers below Zenon 10 may start quicker then the initialisation of configuration is completed. This may case that an empty config-file name is handed over the driver-object, which does communication and variable handling. Description ...
AccessOPCUA: OPC UA process gateway does not re-initialise propperly under specific circumstances during reload of the service engine
Summary Reload issues when reloading multiple projects in sequence Description Reload issues when reloading multiple projects in sequence Issue Number: 244234 Fixed on Date: 17.9.2021 Versions: 8.10 0 BUILD 88647 | 8.20 0 BUILD 88924
'Export Alarms' and 'Export Events' functions do not export equipment groups
Summary 'Export Alarms' and 'Export Events' does not use equipment model selection from column settings Description 'Export Alarms' and 'Export Events' does not use equipment model selection from column settings Issue Number: 212902 Fixed on Date: ...
Trend curves disappear when the dynamic zoom function is used in the extended trend; Block Array Variables; extended trend
Summary Extended trend with block array data allows zoom and mouse manipulation (drag, wheel) of diagram like any other type of trend. Description Extended trend with block array data allows zoom and mouse manipulation (drag, wheel) of diagram like ...
SPRECON870 - default value for reverse direction
Summary Default value for reverse direction for converted projects is true Description Default value for reverse direction for converted projects is true Issue Number: 246537 Fixed on Date: 16.11.2021 Versions: 8.10 0 BUILD 91824 | 8.20 0 BUILD 92098 ...
LOGIX_ODVA: Requests from driver are sent with a big delay to PLC which causes performance issues
Summary Logix_odva driver - Slow communication after update to 8.20 Description Logix_odva driver - Slow communication after update to 8.20 Issue Number: 246337 Fixed on Date: 15.11.2021 Versions: 8.20 0 BUILD 92098