8.10
Editor crash when mixing the mouse right-left clicks over the Output Window
Description When executing drag & drop in the output window, the Engineering Studio closes unexpectedly if the output window contains Japanese text. This bug has been fixed. Drag & drop works as expected in the output window, regardless of the ...
SNMPNG32: zenSnmpTrapSrv crashes when communicating with many SNMP agents
Summary With SNMPNG32, the zenSnmpSrv crashes when communicating with about 60 or more SNMP agents. This has been fixed. Description A crash is caused by a stack error in the used NetSNMP library when polling the agents. This bug in the library has ...
OPCUA32: driver crashes on driver start command under specific circumstances
Description When stopping and starting the OPCUA32 driver via driver command functions, the driver is closed unexpectedly if the commands are executed in a fast time sequence. This behavior has been fixed. To take advantage of this fix: Update to the ...
Beckhoff NG driver imports arrays wrong
Description When importing variables from its TPY file, the Beckhoff TwinCat NG driver imports arrays incorrectly. The cause is that the selection is based on the ID (decoration), but if IDs are present more than once, the data type cannot be ...
3D Configurator cannot open .STEP files that contain japanese characters in their path
Description The 3D Configurator cannot open STEP files with Japanese characters in the path. E.g. “C:\新しいフォルダー\foo.step”. Nothing is displayed. However, it works with OBJ files. This issue has been fixed. It is now possible to open a *.step file ...
"Function for Gantt in screen ETM" not automatically saved
Description When configuring the "Function for Gantt in screen ETM" property for a variable in the limit values, this configuration is not saved. This error has been fixed. The configuration of the "Function for Gantt in screen ETM" property is saved ...
"&" symbol is displayed as _ in CEL and AML list
Description Variables whose identification contains the "&" character display an underscore in the AML and CEL instead. For example, "Name&Project" becomes "Name_Project". This behavior has been modified. The "&" character is no longer replaced and ...
Crash when Editor is started a 2nd time
Description If the Engineering Studio (aka "Supervisor" or "Editor") is started a second time while an instance is already running, both instances are terminated. This behavior has been modified. As expected, the Engineering Studio can only be ...
IEC61850DriverConfigurationWizard.scadaAddIn: wizard displays exception and does not load specific .scd file
Description The IEC 61850 driver configuration wizard does not read SCD files correctly from zenon 8.10 onwards. Reading is started, but the wizard is then closed with an unhandled exception. In zenon 8.00, reading takes place without errors. This is ...
Web Engine Compiler fails if in a screen switch function no screen is configured
Summary Compiling the HTML Web Engine fails if no screen has been defined in a screen switch function. This error has been fixed. Description In the HTML Web Engine, compiling a project failed if no screen was defined in a screen switch function or ...
format of the timestamp in the RGM does not change
Description In zenon 8.00 and 8.10 the format for the timestamp in the RGM is not taken over from the settings in Windows. Changes of the date format in the operating system are not considered in the Service Engine. From version 8.20 it works as ...
CEL: At acknowledgement, the alarm text not translated in CEL
Description When acknowledging an alarm, the translation is not correct when using language switching. "Acknowledged" is translated correctly. However, the "Limit value text" will not be translated. This error occurred in versions 7.11 to 8.20. The ...
zenon logic service version 10 for raspberry pi does not start on current buster (debian 10) distribution
Description On a Raspberry Pi with Debian 10 (Buster) distribution the zenon Logic Service is tried to start. The start is aborted with an error message referring to ... version `GLIBC_2.29' not found ... The reason are zenon Logic Service functions ...
AccessICCP: high cpu load on startup and high cpu load on connect of an ICCP client results in no connection being established
Description When connecting via the ICCP/TASE.2 protocol, the connection will not be established if a high CPU load occurs when starting the Process Gateway or when connecting an ICCP client. This can happen due to the initialization of a large ...
GOOSE publisher and subscriber in the straton IEC850 server use ASCII strings
Summary In the straton IEC850 server, the GOOSE publisher sends unicode strings as ASCII strings. Also the GOOSE subscriber in the straton IEC850 server only supports ASCII strings Description In the straton IEC850 server, the GOOSE publisher sends ...
System Information Collector (SIC) may produce an unhandled exception when selecting the “Databases” node.
Summary SIC tool may close unexpectedly when selecting the tree node Scada -> Versions -> Version XXXX -> SqlConnection -> Databases. DescriptionSIC tool may close unexpectedly when selecting the tree node Scada -> Versions -> Version XXXX -> ...
Alarm Message and Chronologic Event lists visibility may not work correctly in the Runtime.
Summary Alarm Message and Chronologic Event lists may be visible when the value of the variable linked to the visibility property is set to hide before opening the respective screens in the Runtime. DescriptionAlarm Message and Chronologic Event ...
When symbols are dragged and dropped from the global symbol library the “Reference point“ property is sometimes lost or reset.
Summary When a symbol is dragged out and dropped from the global symbol library the “Reference point“ property is sometimes lost or reset to something different. This effect does not occur with the local symbol library. DescriptionWhen a symbol is ...
zenVNCClie: Sometimes it is not possible to open a saved connection.
Summary When a connection with the zenon VNC Client is established, the connection can be saved into a .rdc file. On opening the saved connection an error message appears: “Invalid Remote Desktop Server specified.“ DescriptionWhen a connection with ...
In the startup tool it is possible to set the global project as start project.
Summary In the startup tool it is possible to set the global project as start project in the properties of a zenon version. This causes the runtime not to start. DescriptionIn the startup tool it is possible to set the global project as start project ...
Filter: Time period One day does not work for day with DST at midnight
Summary For the time filter configuration period: 1 day it is necessary to determine the start and the end of the day. If this is the day when the change from standard time to daylight saving time happens (summer to winter) when the start and the end ...
KIEBACK.exe driver enhanced serial port support
Summary The kieback.exe driver has been enhanced to support communication of up to 256 COM ports Description The kieback.exe driver has been enhanced to support communication of up to 256 COM ports Issue Number: 153418 Fixed on Date: 16.10.2018 ...
Implementation of VASS" protocol for zenon Logic"
Summary Issue Number: 30031 Fixed on Date: 25.9.2018 Versions: 8.00 0 BUILD 52082 | 8.10 0 BUILD 65147 | 8.00 0 BUILD 64633
Templates, Translations, ...
Summary Issue Number: 126802 Fixed on Date: 16.11.2018 Versions: 8.00 0 BUILD 53129 | 8.10 0 BUILD 59911
3S_v3: after a reconnect, RDA data could not be read
Summary After a loss of communication, the 3S_v3 driver could reconnect to the PLC and all variables can be read, but the RDA values get not archived any longer. Description After a loss of communication, the 3S_v3 driver could reconnect to the PLC ...
Microsoft.ReportViewer.Winforms uses Newtonsoft.Json.dll as unlisted dependency
Summary Newtonsoft.Json.dll referenced, though it was not needed. Referenced removed. Description Newtonsoft.Json.dll referenced, though it was not needed. Referenced removed. Issue Number: 184718 Fixed on Date: 7.6.2019 Versions: 7.60 0 BUILD 57804 ...
Interlocked buttons are not displayed properly after Interlock is changed
Summary Buttons and combi elements are now displayed right if the linked interlocking changes. Description Buttons and combi elements are now displayed right if the linked interlocking changes. Issue Number: 184043 Fixed on Date: 20.5.2019 Versions: ...
Gantt Trend dont recognize variable value 32768
Summary Gantt display in ETM did not correctly handle values outside -32000 ... +32000, so the limit 32768 (hex 0x8000, bit #15) was not recognized. Description Gantt display in ETM did not correctly handle values outside -32000 ... +32000, so the ...
HTML Web Engine compiler cause zenon editor crash
Summary Sometimes Editor crashes during XML Export of screens containing .Net ActiveX controls Description Sometimes Editor crashes during XML Export of screens containing .Net ActiveX controls Issue Number: 183459 Fixed on Date: 15.5.2019 Versions: ...
Japanese character(font) in output windows was not displayed correctly
Summary I.e. Japanese character are bigger than English and need to more place in output and maybe it's the reason. Description I.e. Japanese character are bigger than English and need to more place in output and maybe it's the reason. Information ...
ALLENDF1 driver: Random crash of the driver
Summary Driver sporadically crashes during read after unadvising a variable. Description Driver sporadically crashes during read after unadvising a variable. Issue Number: 184748 Fixed on Date: 21.5.2019 Versions: 8.00 0 BUILD 59775 | 8.10 0 BUILD ...
ALLENDF1 driver: datablock 0, offset 3 cannot be read in specific circumstances
Summary ALLENDF1 Option "Offset considers data type" does not work with input and output file types Description ALLENDF1 Option "Offset considers data type" does not work with input and output file types Issue Number: 184375 Fixed on Date: 17.6.2019 ...
OmronEIP: If PLC is not accessible and Block read is enabled during during Runtime start, the Invalid bit" is not correctly set for all variables"
Summary OmronEIP: If PLC is not accessible and Block read is enabled during during Runtime start, the "Invalid bit" is not correctly set for all variables Description OmronEIP: If PLC is not accessible and Block read is enabled during during Runtime ...
Objectlist in the Worldview Overview screen does not work on Multimonitor System
Summary Station list in worldview overview is cleared at refresh - caused by opening another instance of world view screen e.g. Description Station list in worldview overview is cleared at refresh - caused by opening another instance of world view ...
The prefilter Delete Old Symbols " in the 3sv3 driver variable import does not work."
Summary The prefilter "Delete Old Symbols " in the 3sv3 driver variable import does not work. Description The prefilter "Delete Old Symbols " in the 3sv3 driver variable import does not work. Information However, the customer has only the Workaround ...
zenon silent crash was generated, when quickly opening or closing an AML-Screen on Panel running with W10 Enterprise Edition.
Summary Solution Sporadically zenon Runtime crash due to heap corruption after closing the zenon alarm list. Issue Number: 186697 Fixed on Date: 19.6.2019 Versions: 7.50 0 BUILD 58685 | 7.60 0 BUILD 59794 | 8.00 0 BUILD 59775 | 8.10 0 BUILD 59911
Chronological Event List: During the acknowledgement process the text will be not translated at the CEL.
Summary Solution Now, the limit text will be translated correctly. Issue Number: 186700 Fixed on Date: 18.6.2019 Versions: 7.50 0 BUILD 58685 | 7.11 0 BUILD 58691 | 7.20 0 BUILD 58726 | 7.60 0 BUILD 59794 | 8.00 0 BUILD 59775 | 8.10 0 BUILD 59911
ISPIP: state with subelement number 255 is not correctly considered for successful command response
Summary . Description . Issue Number: 187333 Fixed on Date: 4.7.2019 Versions: 7.60 0 BUILD 59794 | 8.00 0 BUILD 59775 | 8.10 0 BUILD 59911
T5BusExZenOnRT : Zenon to Logic shared memory. Some value change are lost in VMRead
Summary If values from zenon Runtime to Logic runtime must be buffered due to a sharing violation of shared Memory these values are never re-sent if every 100ms cycle there are set values to be transefered from Logic Runtime to zenon Runtime. ...
Japanese characters are stored incorrectly in the metadata database
Summary The treatment of non-ascii characters did not work properly in the Analyzer Export Wizard for 3.10 and 3.20 and in the Analyzer Export Wizard for 3.30. Multiple tables were affected by this problem. Now, those characters are treated correctly ...