8.00
API Rema: it is not possible to create the first Chain state
Summary - Description - Issue Number: 142083 Fixed on Date: 12.7.2018 Versions: 7.60 0 BUILD 49532 | 8.00 0 BUILD 50155
SapParameter.set_Value() does not work
Summary Empty string ("") for field name is now treated as "not a structure field", i.e. use parameter.set_Value("", ) and parameter.get_Value("") resp. to address the parameter itself, and not a structure field. Same applies to SapRow objects ...
VSTA API Function Units.Import() return false value
Summary The API method Unit.Import() returns now TRUE when the import was successful. Description The API method Unit.Import() returns now TRUE when the import was successful. Issue Number: 148337 Fixed on Date: 14.8.2018 Versions: 7.20 0 BUILD 50281 ...
Enhancement MITSUBISHI_FX Driver String value padding
Summary Issue Number: 141271 Fixed on Date: 14.8.2018 Versions: 7.20 0 BUILD 50281 | 8.00 0 BUILD 50155 | 7.50 0 BUILD 51485 | 7.60 0 BUILD 50324
The same variable name with different Case-sensitive characters aren't recognized and when delete the duplicate" the editor crash"
Summary it's again possible to create variables with names that only differ in case Description it's again possible to create variables with names that only differ in case Issue Number: 146515 Fixed on Date: 6.8.2018 Versions: 8.00 0 BUILD 50155
Command Group property is disabled in the 7.60 editor for variables that are based on an input" driver object type with the "write set value" property not set and disabled"
Summary Command group can be linked even if the "write set value" property is not set. Description Command group can be linked even if the "write set value" property is not set. Issue Number: 90928 Fixed on Date: 6.8.2018 Versions: 7.60 0 BUILD 50324 ...
Extended Trend: Converting a project from 7.xx to 8.00 the curvename automaticaly will set to variable name but in 7.xx the curve name was always static
Summary The default configuration after converting a project from 7.xx to 8.xx is now "Static". The original curve name is not lost. Description The default configuration after converting a project from 7.xx to 8.xx is now "Static". The original ...
zenon Logic Workbench: Editor variables 'Externally visible' do not get the 'Embed symbol' property activated and are not updated via LogicToScada connection
Summary 'Embed Symbol' is always set for variables interchanged with zenon runtime Description 'Embed Symbol' is always set for variables interchanged with zenon runtime Information Activate Project - Settings... - Compiler - Embed symbols of all ...
Addin Services seem to cause Memory leak
Summary - Description - Information I suggested the customer to trigger a zenon function with a wizard inside the worker thread. Wizards do not have this issue since the appdomain is destroyed after finishing and the memory is released. I do not know ...
Spontaneous allocations do not work in a hirarchical project structure
Summary Cross project data point usage for assignment was broken Description Cross project data point usage for assignment was broken Issue Number: 140653 Fixed on Date: 16.7.2018 Versions: 8.00 0 BUILD 50155
OPCUA32 driver closes unexpectedly on closing the runtime under specific circumstances
Summary n.a. Description n.a. Issue Number: 141799 Fixed on Date: 5.7.2018 Versions: 8.00 0 BUILD 50155
Updating context list on Standby crashes Server
Summary No crash happening anymore. The lists are updated correctly (on server and standby) Description No crash happening anymore. The lists are updated correctly (on server and standby) Issue Number: 146853 Fixed on Date: 29.8.2018 Versions: 7.60 0 ...
Typed text is deleted when Polish special letter Ä " is typed in Runtime"
Summary Alt Gr was accidentially treated as Ctrl Description Alt Gr was accidentially treated as Ctrl Issue Number: 135155 Fixed on Date: 23.8.2018 Versions: 7.60 0 BUILD 50324 | 8.00 0 BUILD 51046
AccessOPCUA: The OPC UA server has been enhanced with additional functionality.
Additional functionality to provide support for history read of alarms. Additional functionality to provide CEL entries as online events Additional functionality to provide history read of CEL entries
Summary Projects where the setting for alarms "use reactivated time" is used, are not supported Alarms are now derived from a user defined AMLConditionType (ConditionType -> AcknowledgabeConditionType -> AlarmConditionType) where additional ...
LOGIX_ODVA Driver: Cannot communicate with Multi-dimensional array variables
Summary Issues with multi-dimensional arrays with some special projects Description Issues with multi-dimensional arrays with some special projects Issue Number: 151124 Fixed on Date: 14.9.2018 Versions: 8.00 0 BUILD 51046 | 7.60 0 BUILD 50946
When using SymbolLibrary.ExportToXml Backups become unusable when graphic files are used
Summary - Description - Issue Number: 148001 Fixed on Date: 14.9.2018 Versions: 8.00 0 BUILD 51046 | 7.60 0 BUILD 50946
RGM Recipe Groups: bad performance with many Variables
Summary The performance while loading variables for a recipe group is improved. Description The performance while loading variables for a recipe group is improved. Issue Number: 137651 Fixed on Date: 10.9.2018 Versions: 8.00 0 BUILD 51046 | 7.20 0 ...
SPRECON870: crash on reload - deactivating internal connection
Summary - Description - Issue Number: 150772 Fixed on Date: 10.9.2018 Versions: 8.00 0 BUILD 51046
Alarm aggregation via equipment modell using alarm classes from global project does not work
Summary Linkage to alarm classes is now id based also in the equipment model groups. So it also works with alarm classes for global project. I did the same for all the variables that can be linked to a group (not only alarm linkage but also for net ...
Datei32: variable must not be written with poke_ack bit set
Summary Issue Number: 150513 Fixed on Date: 6.9.2018 Versions: 8.00 0 BUILD 51046 | 7.20 0 BUILD 51917 | 7.50 0 BUILD 51485 | 7.60 0 BUILD 50946 | 7.11 0 BUILD 58691
ICCP driver in zenPG does not send RBE always in the same way
Summary ICCP zenPG - when a report by exception is sent the sequence of the contained items is undefined Description ICCP zenPG - when a report by exception is sent the sequence of the contained items is undefined Issue Number: 150336 Fixed on Date: ...
variables with constant length cannot be imported with the TIA driver.
Summary S7TIA driver - string variables with a constant length cannot be imported Description S7TIA driver - string variables with a constant length cannot be imported Issue Number: 147128 Fixed on Date: 30.8.2018 Versions: 8.00 0 BUILD 51046 | 7.60 ...
MC send message function with group-call don't call the next user if the first user not respond on call
Summary This Modem specific issue has been resolved. Description This Modem specific issue has been resolved. Issue Number: 138646 Fixed on Date: 3.7.2018 Versions: 7.50 0 BUILD 51485 | 8.00 0 BUILD 52082 | 7.60 0 BUILD 52066
Editor crash when creating a workspace backup during a couple of screens from more than 1 projects are open
Summary When a (faceplate) screen is open containing a screen container element using a global template and a workspace backup is created the editor sometimes crashed. Description When a (faceplate) screen is open containing a screen container ...
OPCUA: communication with SecurityPolicy_Basic256Sha256 activate session refused by remote server
Summary Communication with SecurityPolicy_Basic256Sha256 activate session refused by remote server Description Communication with SecurityPolicy_Basic256Sha256 activate session refused by remote server Issue Number: 153858 Fixed on Date: 10.10.2018 ...
RDA (Typ-4) Real-time Data Acquisition - telegram not supported start 'milliseconds' offset from header
Summary Real time data acquisition with type 4 produces time stamps with wrong millisecond values. Description Real time data acquisition with type 4 produces time stamps with wrong millisecond values. Issue Number: 153174 Fixed on Date: 10.10.2018 ...
zenPG ICCP as Server: when receives a MMS.write without Time then calls Poke (value , status, time) without T_INTERN in status bits.
Summary zenPG ICCP Server does not set T_INTERN/T_EXTERN bit under all circumstances Description zenPG ICCP Server does not set T_INTERN/T_EXTERN bit under all circumstances Issue Number: 136777 Fixed on Date: 5.10.2018 Versions: 7.60 0 BUILD 52066 | ...
VBA/Addin: Runtime Crash after Reload, when VBA is changed while an automatically launching Service is active.
Summary Runtime crashed when restarting Add-In Service after reload of VBA. Description Runtime crashed when restarting Add-In Service after reload of VBA. Information - Do not change VBA. - Use VSTA. - Perform a restart instead of a reload in case ...
Runtime hangs up sporadically when opening trend screens on clients
Summary The values which come from process variables will not be displayed (=invalid value) in the curves list unless the driver sends an update for the advised values. Previously the list was blocked by the value request if there was no current ...
calling the LicenseEntry::Values API method causes a memory leak
Summary A memory leak in the API method LicenseEntry::Values was fixed, as well as a leak in the screen switch function of the report viewer Description A memory leak in the API method LicenseEntry::Values was fixed, as well as a leak in the screen ...
IEC870 - Driver crash on responses with private TypeIDs 137-139
Summary telegram size for private type ids is checked before accessing the data. Description telegram size for private type ids is checked before accessing the data. Issue Number: 151576 Fixed on Date: 4.10.2018 Versions: 8.00 0 BUILD 52082
Import/Export of ScreenSwitch(ExtendedTrend) crashes Editor
Summary xml import of curves works correct Description xml import of curves works correct Issue Number: 150812 Fixed on Date: 4.10.2018 Versions: 8.00 0 BUILD 52082
AccessModbus: zenon process gateway closes when an invalid modbus request is received
Summary The Accessmodbus process gateway returns a modbus exceptionerror when an invalid modbus request is received Description The Accessmodbus process gateway returns a modbus exceptionerror when an invalid modbus request is received Issue Number: ...
delayed alarms don't appear in AML
Summary delayed limits of variables receiving values with external timestamps did not work correctly Description delayed limits of variables receiving values with external timestamps did not work correctly Issue Number: 152381 Fixed on Date: ...
zenPG ICCP as client: closes connection while received an InformationReport with segmented COTP sections
Summary ICCP - COTP fragments with less than 3 bytes were treated as invalid. Description ICCP - COTP fragments with less than 3 bytes were treated as invalid. Issue Number: 155630 Fixed on Date: 25.10.2018 Versions: 7.50 0 BUILD 52376 | 8.00 0 BUILD ...
ETM: cursor output in diagram only works if screenswitch has active curves
Summary For a diagramm with integrated scan list, on "Cursor on" each active curve is shown in the scan list, regardless of how many curves were activated in the screen switch function. Description For a diagramm with integrated scan list, on "Cursor ...
zenon stops working when using Scheduler in compatibility mode
Summary In a network setup where the server uses an older zenon version (7.10 and older) than a client (e.g. 7.60) then the Server may stop working when it tries to open the Scheduler screen after a schedule has been created on the client. The client ...
ISPIP: Resetting of an alarm does not work as expected
Summary - Description - Solution The ISPIP driver correctly recognizes the cleared state of the alarm. Issue Number: 155292 Fixed on Date: 7.11.2018 Versions: 7.60 0 BUILD 52515 | 8.00 0 BUILD 53129
ISPIP driver: Not all value changes are sent to the runtime
Summary - Description - Issue Number: 158533 Fixed on Date: 4.12.2018 Versions: 7.60 0 BUILD 53270 | 8.00 0 BUILD 53974
T5BusExZenOnRT: Unexpected bus properties" error message with the zenon logic runtime failing to start, when using compatible runtime files compiled for 7.60 in the 8.10 editor"
Summary project with zenon logic project in 8.10, containing the "logic to scada runtime connection" driver in the fieldbus configuration compiled compatible for runtime files for 7.60, zenon logic runtime fails to start with the error "unexpected ...