Editor stopt unexpected when reading the data sets from external SQL server datasource.
Summary Editor stopt unexpected when reading the data sets from the external SQL server datasource. The rdl file was developed external SQL server database as datasource are not supported. All rdl files for the report viewer must contain a valid XML ...
Report Generator: "Set filter" element does not get updated from Time Filter
Summary Report Generator screen and setting a different filter with the screen specific function (Filter...) the used filter works, but the control-element does not get updated. DescriptionReport Generator screen and setting a different filter with ...
Archive Evacuation for RDA Archive not working for *.arx archives.
Summary Historian RDA Archive doesn't evacuate intern archive format *.arx archives DescriptionHistorian RDA Archive doesn't evacuate intern archive format *.arx archives Solution Evacuation for RDA archive working. Issue Number: 37195 Fixed on Date: ...
Historian On change archive in start image stores wrong time
Summary 'On change' archive in start image stores variables having internal time stamp with wrong time. Description'On change' archive in start image stores variables having internal time stamp with wrong time. Solution Time for a record is now taken ...
Extended trend don't disabled Double cursor for curves with typ array data.
Summary It is not possible to use the double cursor for the array data type. DescriptionIt is not possible to use the double cursor for the array data type. Solution Double cursor is hidden if data origin is Array Data. Issue Number: 31254 Fixed on ...
no status bits and timestamp available for writing access for all intern driver variables
Summary From the Build versions 7.20 Build 38805; 7.50 Build >38795; 7.60 Build >38809 on we added a new option which will affect the Tag counting for internal driver variables. This setting is project wide and can be found in the project.ini or in ...
When renaming a structure element within a structure datatype in the zenon editor, the old name and also the new name of the structure element are listed in zenon Logic under Types.
Summary After renaming a structure element of a structure datatype in the zenon editor, the old and the new name of the structure element are shown in zenon Logic unter section Types. DescriptionAfter renaming a structure element of a structure ...
The IEC62056 driver should support historic values with the format OBIS*?.
Summary The IEC62056 driver should support the OBIS*? format of historical values. DescriptionThe IEC62056 driver should support the OBIS*? format of historical values. Solution This issue has been addressed by supporting the OBIS*? address format ...
Unexpected closing of RT if the SMTP/POP protocol password is too long.
Summary If SMTP/POP protocol is used with Message Control it can happen that the RT is unexpected closed if the SMTP/POP email account password is too long(more than 13 characters). DescriptionIf SMTP/POP protocol is used with Message Control it can ...
The RemoteRT driver does not consider the following changes in the editor when afterwards a reload of the runtime is performed:
modifying a former incorrect net address to a correct net address and then perform a reload of the zenon runtime does not lead to a correct communication behaviour (variables stay INVALID) modifying a former correct symbolic address of a variable to an incorrect symbolic variable and then perform a reload of the zenon runtime does not lead to a communication error (va
Summary The RemoteRT driver behaves unexpected under following circumstances: change over from a former incorrect net address to a correct net address and then perform a reload of the zenon runtime does not lead to a correct communication ...
The DCA gateway (AccessDCA) does behave unexpectedly after several hot reloads of the zenon runtime. In the course of this the DCA gateway displays a message box saying "Project is not loaded! Please load the project".
Summary After several reloads of the zenon runtime the DCA gateway (AccessDCA) behaves unexpectedly and displays a message box saying "Project is not loaded! Please load the project". DescriptionAfter several reloads of the zenon runtime the DCA ...
The maximum amount of concurrent shared memory connections between zenon logic runtime and zenon runtime should be increased from 32 to 256.
Summary The current maximum (32) of concurrent shared memory connections between zenon logic runtime and zenon runtime should be increased to 256. DescriptionThe current maximum (32) of concurrent shared memory connections between zenon logic runtime ...
When using multidimensional arrays with driver object type special markers of the LOGIX_ODVA driver, the LOGIX_ODVA driver behaves unexpectedly when trying to read the values of those array variables during runtime of zenon.
Summary When the LOGIX_ODVA driver reads variable values of multidimensional arrays with driver object type special markers during zenon runtime, the LOGIX_ODVA driver behaves unexpectedly when trying to read the values of those array variables. ...
When accessing user definied structures with a size larger than 65k the LOGIX_ODVA driver behaves unexpectedly.
Summary When the LOGIX_ODVA driver accesses user defined structures of driver object type PLC Marker, the LOGIX_ODVA behaves unexpectedly. DescriptionWhen the LOGIX_ODVA driver accesses user defined structures of driver object type PLC Marker, ...
When writing values on string variables of the LOGIX_ODVA driver, the string "\1_zenon\zenon\zenon720\source\zenon drivers\drvkit\TreiberObj.cpp" is appended to the actual value.
Summary The string "\1_zenon\zenon\zenon720\source\zenon drivers\drvkit\TreiberObj.cpp" is appended to the actual string value when writing a value to a string variable of driver LOGIX_ODVA DescriptionThe string "\1_zenon\zenon\zenon720\source\zenon ...
When importing a UDFB consisting of a set of variables in zenon Logic, all properties of the variables within the UDFB are reset when the zenon Logic workbench is closed and reopened again.
Summary The properties of a set of variables within a UDFB which is imported to zenon Logic are reset when the zenon Logic workbench is closed and reopened again. DescriptionThe properties of a set of variables within a UDFB which is imported to ...
The Modbus Process gateway (AccessMODBUS) should support unit IDs higher than 127.
Summary Unit IDs higher than 127 should be supported by the Modbus Process gateway (AccessMODBUS) DescriptionUnit IDs higher than 127 should be supported by the Modbus Process gateway (AccessMODBUS) Solution This issue has been addressed by ...
The zenon runtime shows unexpected behaviour when a high amount of value changes of variables of the Modbus Process Gateway (AccessMODBUS) take place. This is the case when in addition to the value changes also the number of variables which the Modbus Process Gateway contains is very high.
Summary When the Modbus Process gateway (AccessMODBUS) contains a high amount of variables and the values of these are changing very fast, the zenon runtime behaves unexpectedly. DescriptionWhen the Modbus Process gateway (AccessMODBUS) contains a ...
Some drivers, e. g. MODRTU32, cause the zenon Logic runtime to show unexpected behaviour when running as IEC 61850 server when the driver connectes to the listening port of the IEC 61850 server within the zenon Logic runtime.
Summary When the zenon Logic runtime is running as a IEC 61850 server, the connection attempt of some drivers, e. g. MODRTU32 to the listening port of the IEC 61850 server within zenon Logic results in an unexpected behaviour of the zenon Logic ...
AccessOPCUA32: Communication with the OPC UA server in the process gateway is no longer possible when the OPC UA client does not expire publish requests
Summary When an OPC UA client uses a timeouthint with the value "0" in PublishRequests, indicating that the publish request does not time out, the OPC UA server does not correctly consider the value "0" as no expiry and instead immediately expires ...
OPCUA32: The OPC UA client driver closes with an unhandled exception when browsing variables from an OPC UA server with a specific address space
Summary When browsing variables with the OPCUA32 OPC UA client driver in the zenon editor from an OPC UA server that uses a specific address space containing endless recursions for hierarchical references, the OPC UA client driver in the editor ...
Incorrect API objects for events of the IRGMREcipeGroups object
Summary When using events of the IRGMRecipeGroups object in the API in the runtime, some events do not behave correctly RecipeCreated VersionCreated RecipeDuplicated VersionDuplicated VersionDuplicatedRead DescriptionWhen using events of the ...
zenon Runtime closed unexpected under specific circumstances.
Summary When duplicating a zenon project, which includes an WPF element created with our zenon 3D configuration tool, it may happen that the zenon Runtime close unexpected when opening the screen with the 3D WPF element. DescriptionWhen duplicating a ...
zenon Editor – Missing *.cdwpf file of created 3D Configurator WPF element.
Summary The created *.cdwpf file of the zenon 3D Configurator is someway not automatically included at the zenon Editor –> Project tree –> Files –> Graphics. DescriptionThe created *.cdwpf file of the zenon 3D Configurator is someway not ...
zenon Editor closed unexpected under specific circumstances.
Summary It could occur that the zenon Editor close unexpected, when working with zenon 3D Configurator Tool and updating variables in the 3D Tool then reactivate at the zenon Editor another zenon project again. DescriptionIt could occur that the ...
Invisible button element may open the set point input dialog in the Runtime.
Summary Clicking on an invisible button element may open the set point input dialog in newer runtimes versions when the runtime files were built to an earlier version. DescriptionClicking on an invisible button element may open the set point input ...
It should not be possible to set the line color of static elements to automatic in the Editor.
Summary The property line color of static elements should not change to automatic when transferring the format of other screen element in the Editor. DescriptionThe property line color of static elements should not change to automatic when ...
S7 1500/1200 driver, it should be possible to select 'ap14' file
Summary The driver now also allows to select TIA 14, TIA14.1 Projects. So it should be also allow the file extension ap14 for the TIA project selection DescriptionThe driver now also allows to select TIA 14, TIA14.1 Projects. So it should be also ...
Runtime may produce an unhandled exception when performing a long right-click over a button.
Summary The Runtime may produce an unhandled exception on a user long right-click on a button linked to a Close Frame function with multiple virtual monitors available. DescriptionThe Runtime may produce an unhandled exception on a user long ...
Programming Interface – method `createDynamicProperty()‘ issue.
Summary The method `createDynamicProperty()‘ return an exception: Given property doesn´t exist. This could occur, when creating a dynamic property in a screen switch function. Example given: zFunk.SetDynamicProperty("PictSwitch.Picture", ...
Under specific circumstances the Universal slider element may not react in the Runtime.
Summary The Universal slider may not react in the Runtime on user interaction when the linked variable uses linear value adjustment and it is linked via a screen switch function. DescriptionThe Universal slider may not react in the Runtime on user ...
It may not be possible to add a new point in the polygon element in the Editor
Summary When positioning the mouse cursor between the first and the last polygon point in the Editor it is not possible to add a new point as the option “Adding a node in the selected element” is greyed out. DescriptionWhen positioning the mouse ...
Command routing in the AccessDNP3 process gateway does not work correctly when the master issues trip or close commands and a boolean variable is used in zenon.
Summary When using command routing in the AccessDNP3 process gateway with a boolean variable linked to a configured binary output in the DNP3 outstation, command routing does not work when a master issues a trip or a close command. The AccessDNP3 ...
The AccessOPCUA OPC UA server in the process gateway allows write requests of OPC UA clients when the variable status is INVALID and updates the internal shadow value.
Summary When a variable configured in the OPC UA server in the process gateway has status INVALID an OPC UA client can still write the value and the value will get updated in the OPC UA server itself. The value is not sent to the runtime and the PLC. ...
The variable value is updated in the OPC UA server after a client has written the value, although the value in the zenon runtime is set to alternate value (ALT_VAL status)
Summary When an OPC UA client writes a value for a variable that is set to ALT_VAL in the runtime, the value is written and updated in the OPC UA server although the value is not updated in the zenon runtime due to the ALT_VAL status. DescriptionWhen ...
Screens deleted on the server are not deleted on clients in the runtime with a network project
Summary When deleting screens in a network project, screens are deleted on the runtime server but not on runtime clients DescriptionWhen deleting screens in a network project, screens are deleted on the runtime server but not on runtime clients ...
The “transparency gradient color” property for buttons may not be set in the Editor.
Summary It may not be possible to set the same value for the “transparency gradient color” and “transparency of the fill color” so that the first property value changes inadvertently in the Editor. DescriptionIt may not be possible to set the same ...
Functions detail view may not be refreshed when a variable is renamed in the Editor.
Summary When a variable is renamed in the Editor the function parameters fields may not be updated so that they continue to display the previous variable name. DescriptionWhen a variable is renamed in the Editor the function parameters fields may not ...
An API Error occurs, if a language file is created via the API and a keyword gets added after the language file creation.
Summary If a keyword was added to a language file via the API after the language file creation, the following API error occurred: Attempted to read or write protected memory. This is often an indication that other memory is corrupt. DescriptionIf a ...
Creating a workspace backup may produce an unhandled exception in the Editor.
Summary Editor may close unexpectedly when screens are open during the backup process of a workspace containing a global and standard projects . DescriptionEditor may close unexpectedly when screens are open during the backup process of a workspace ...