7.60
Under specific circumstances the alarm message list may show graphical artefacts in the runtime.
Summary When moving a screen within the area of the alarm message list the alarm list may show graphical artefacts in the runtime. DescriptionWhen moving a screen within the area of the alarm message list the alarm list may show graphical artefacts ...
The activated font list may change when deleting a font list in the editor.
Summary When deleting a font list the current activated font list may change despite it still exists in the editor. DescriptionWhen deleting a font list the current activated font list may change despite it still exists in the editor. Solution An ...
It may happen that list node objects are not expanded in the editor detail view.
Summary When expanding list nodes in the editor detail view using the “expand selected” option it may be only extended the nodes within the selected area. DescriptionWhen expanding list nodes in the editor detail view using the “expand selected” ...
The extended trend screen refresh rate property may not accept a valid input value typed in the editor and runtime.
Summary It is not possible to insert a valid extended trend screen refresh rate in the editor and runtime when typing first the decimal separator (.) so that it is displayed a warning message. DescriptionIt is not possible to insert a valid extended ...
The standard recipe filter dialog should not display "show this dialog in the runtime" option in the runtime.
Summary The standard recipe filter dialog should not display "show this dialog in the runtime" option in the runtime when this is enabled in the editor. DescriptionThe standard recipe filter dialog should not display "show this dialog in the runtime" ...
It may happen that the screen elements "display color preview" feature is not selectable in the editor.
Summary The screen element "display color preview" feature may be grayed out after configuring a variable in the line color property in the editor. To make it accessible it is required to select the screen element again. DescriptionThe screen element ...
The XML import of reaction matrices does not update the existing items information displayed in the editor detail view.
Summary When a reaction matrix is replaced via XML import its information is not updated in the editor detail view despite the configuration is correctly imported. DescriptionWhen a reaction matrix is replaced via XML import its information is not ...
Under specific circumstances the editor may close unexpectedly when deleting an integration project from the workspace.
Summary The editor may close unexpectedly when deleting from the workspace an integration project containing sub-projects and all the projects have been backed up. DescriptionThe editor may close unexpectedly when deleting from the workspace an ...
The property window may not be refreshed when copy and paste a screen element in the editor.
Summary The “position” properties are not updated when copy and paste a screen element to a different position in the editor. DescriptionThe “position” properties are not updated when copy and paste a screen element to a different position in the ...
The editor may stop responding after changing the rounding of a screen element.
Summary The editor hangs when using the mouse to adjust the rounding of a rectangle with 0 (zero) pixels for height or width. DescriptionThe editor hangs when using the mouse to adjust the rounding of a rectangle with 0 (zero) pixels for height or ...
The history of changes may not log a screen element position change in the editor.
Summary Despite the detailing level is set to "object", the history of changes may not log the change of a screen element position when using the "position" properties in the editor. DescriptionDespite the detailing level is set to "object", the ...
The "flashing color from limit value" should not be available to all screen elements in the editor.
Summary The "flashing color from limit value" property is intended only for elements with a filling area, so that it should not be displayed for the line element in the editor. DescriptionThe "flashing color from limit value" property is intended ...
The context menus of some screen elements properties may display blank entries in the editor.
Summary Screen elements supporting styles may display empty entries in the context menus of some properties in the editor property window. DescriptionScreen elements supporting styles may display empty entries in the context menus of some properties ...
The insert key may not work in the scheduler.
Summary Context menu and tool tip show that the insert key can be used to create new scheduler groups in the scheduler but this does not work. DescriptionContext menu and tool tip show that the insert key can be used to create new scheduler groups in ...
It may happen that the production and facility scheduler API cannot be accessed from the editor and runtime.
Summary The production and facility scheduler API may not be accessible from the editor and runtime in new projects. DescriptionThe production and facility scheduler API may not be accessible from the editor and runtime in new projects. Solution An ...
The arc of a circle element may not be resized in the editor.
Summary The arc of a circle element cannot be resized in the editor using the handles together with the keyboard buttons in the editor. DescriptionThe arc of a circle element cannot be resized in the editor using the handles together with the ...
The editor may not add correctly a new node to specific screen elements.
Summary When adding a new node close to the start point of a polygon, polyline and pipe elements this can be miscalculated and misplaced and cause the editor not responding. DescriptionWhen adding a new node close to the start point of a polygon, ...
The frame handle coordinates window may not be accessible in the editor.
Summary When double clicking a frame handle it is not possible to reach the coordinates window as it is opened the frame form editor. DescriptionWhen double clicking a frame handle it is not possible to reach the coordinates window as it is opened ...
Screen elements may display a black area in the runtime.
Summary The numerical value and dynamic text elements may display a black area when the fill color is set from a color palette and the write set value is done directly in the element in the runtime. DescriptionThe numerical value and dynamic text ...
Under specific circumstances the dynamic text element text color does not display the violated limit color in the runtime.
Summary If a dynamic text element is configured to use the text color from the linked variable limit and the write set value input is set to the element, the limit color is only displayed while the input is being typed switching to black after being ...
The segment of a circle line border may move in the editor.
Summary The segment of a circle line border (not a continuous line) may move unintentionally if the element is selected in the editor and a line with an arrow start or end type is placed nearby. DescriptionThe segment of a circle line border (not a ...
The "set value/change by" property may not work in the runtime.
Summary The dynamic text element "set value/change by" property may be discarded in the runtime if the write set value is done directly in the element, so that it is only proposed the current value or displayed the input cursor when the element is ...
The user group names assigned to a user may be incorrectly listed in the editor.
Summary After assigning a user group to a user from a standard project, a user group name from the global project is displayed in the "allocate user groups to the user" dialog in the editor. DescriptionAfter assigning a user group to a user from a ...
It should not be possible to enter an empty frame name in the editor.
Summary A frame must have a name, so that it should not be allowed to enter an empty name in the editor. DescriptionA frame must have a name, so that it should not be allowed to enter an empty name in the editor. Solution From now on the frame name ...
The combined element should refresh when displaying the timestamp if the variable value and status change.
Summary When the text of the current state contains a timestamp (%T, %t) the combined element should refresh on each value and state change. DescriptionWhen the text of the current state contains a timestamp (%T, %t) the combined element should ...
Under specific circumstances the name of a project backup may be truncated.
Summary The project backup name may be truncated after the first dot (.) character if the name string contains one or more dot characters. DescriptionThe project backup name may be truncated after the first dot (.) character if the name string ...
The nodes of the screen elements do not move in the correct direction in the editor using the keyboard arrow keys.
Summary It should be not possible to move the polygon, polyline and pipe nodes with the keyboard arrow keys after the elements have been rotated in the editor. DescriptionIt should be not possible to move the polygon, polyline and pipe nodes with the ...
The console window may be displayed during runtime on Windows CE devices when using the OPCUA32 OPC UA client driver
Summary When using the OPCUA32 OPC UA client driver in the runtime on Windows CE devices, the console window may be displayed under specific circumstances where communication with the OPC UA server would fail. DescriptionWhen using the OPCUA32 OPC UA ...
Under specific circumstances a runtime client is not able to connect to the runtime server
Summary With a specific network configuration with an integration project that uses a primary server and a secondary server and a sub project that uses only a primary server without redundancy, a client of the sub project may not be able to connect ...
A variable of the OPCUA32 OPC UA client driver set to alternate value in the runtime may still get updated with a value from the OPC UA server
Summary When a variable of the OPCUA32 OPC UA client driver is set to "alternate value", an update of the value in the OPC UA server will result in the OPCUA32 client driver receiving the value and forwarding this value to the runtime, overwriting ...
The OPC UA server in the process gateway creates an alarm object for boolean variables with alarm limits also if a reaction matrix is used
Summary The OPC UA server in the process gateway also creates an alarm object for the limits when these limits are configured as alarms, when a reaction matrix is linked and used at the variable. DescriptionThe OPC UA server in the process ...
Some alarm attributes do not have a current value in the OPC UA server in the process gateway
Summary With the OPC UA server in the process gateway, some alarm attributes of an alarm object do not have a value even though an alarm has been active prior to the point in time where the OPC UA server was started. DescriptionWith the OPC UA server ...
The OPC UA server in the process gateway produces different texts for the first alarm and consecutive alarms
Summary The OPC UA server in the process gateway produces the text "The alarm has been created" for a first alarm that was created and the text "The alarm severity has increased" for the second and further alarms that are created. DescriptionThe ...
"Failed to evaluate data types" error message appears under specific circumstances when browsing an OPC UA server using the OPCUA32 client driver in the editor
Summary When browsing variables in the editor using the OPCUA32 client driver with a specific OPC UA server configuration in the zenon OPC UA server, an error message from the OPC UA server may appear in the editor following the browse of the server ...
The zenon logic OPC UA server fails to start in case the directory structure for storing the application instance certificate does not yet exist.
Summary When the zenon logic OPC UA server is started for the first time on a PC by default it will attempt to create a self-signed application instance certificate. In case the directory structure for storing the application instance certificate ...
The NodeIds generated by the OPC UA server in the process gateway are not guaranteed unique
Summary When the OPC UA server in the process gateway is used in combination with a runtime with multiple projects, without explicitly configuring any variables in the configuration of the OPC UA server, the NodeIds generated automatically for the ...
The OPC UA server for zenon logic and in the process gateway should no longer check the certificate with security mode none
Summary Since OPC UA specification 1.02 an OPC UA client is no longer required to send its application instance certificate when MessageMode Security "None" is used by the client. Also an OPC UA server is no longer required to send its certificate ...
The application instance certificate generated by the zenon logic OPC UA server is incorrect
Summary The application instance certificate generated by the zenon logic OPC UA server on first startup is incorrect. The certificate does not include a subjectAltname field containing the application Uri and DNS name of the OPC UA server ...
The OPCUA32 OPC UA client driver does not correctly encrypt the password causing the connection to fail
Summary The OPCUA32 OPC UA client driver does not correctly format the password in the UserIdentityToken prior to encrypting the password field. As a result the OPC UA server on the opposite side cannot decrypt the password and the connection cannot ...
zenon Logic RT does not run after download of project with empty profile fields for a variable of T5BusIec850s driver.
Summary Issue in a project with an "IEC 61850 Server incl. GOOSE" configuration, if a variable has the "IEC61850S" profile but empty parameters, e.g. the variable is created manually (instead by on/off-line import) and has not completed information. ...