7.50
zenon Editor and Runtime. Report Viewer screen switch function issue concerning the online filter dialogs after Import/Export.
Summary After exporting and importing a Report Viewer screen switch function at the zenon Editor the online filter dialogs will be no more shown at the zenon Runtime. This applies only for the Report Viewer and not for other screen types as well only ...
Buttons may not work in the runtime under specific circumstances.
Summary Buttons configured as switch may not toggle the linked boolean variable in the runtime. DescriptionButtons configured as switch may not toggle the linked boolean variable in the runtime. Solution The issue has been resolved so that the ...
Screen elements may be displaced in the runtime.
Summary Rotated screen elements may show a pixel shift up and right in the runtime. DescriptionRotated screen elements may show a pixel shift up and right in the runtime. Solution The issue has been fixed so that the screen elements are shown ...
Validation of Batch Control recipes takes very long
Summary In Batch Control recipes can grow very large. The larger and the more complex a recipe is, the longer the Validation takes. Recipes with more than 1000 phases and lots of branches and loops may require several minutes for validation. ...
Metering Point Administration does not work with variables with Special characters in their names
Summary The Metering Point Administration creates some zenon logic code to calculate the relative values. However, if either the absolute value variable or the relative value variable has special characters (like ä, ü, etc.) in its name, then the ...
Command Processing action switch-/pulse-command when Direction="none" by activated 'Watchdog timer' always waits action Timeout and then sets TIMEOUT status bit.
Summary For command actions with 'Switching direction' = "none" the 'Watchdog timer' = "only RV" and "RV and COT" make Command Processing to wait action timeout (default 30s). Then action always sets status bit TIMEOUT - "runtime exceeded" on ...
By action 'Lock' in Editor an interlocking condition can be created but is not used in the Runtime.
Summary In Command Processing, the action type 'Lock' is not supporting interlocking conditions. But in Editor you can create a "condition" - from icon in toolbar or context menu; only copy&paste of conditions from another action type to 'Lock' is ...
When in Command Processing by an action 'Timeout can be canceled' is activated then the NET_SEL status bit stays set for additional Timeout after action execution is completed.
Summary Status bit NET_SEL ("selected in zenon Network") of response variable (RV) stays set for Timeout after command screen was automatically closed when 'Watchdog timeout' is elapsed, but action was not completed in the PLC, additional conditions: ...
When variable used in 'Breaker tripping detection' is deleted during formula was deactivated, the formula cannot be edited anymore.
Summary In Command Processing, there is the option for 'Breaker tripping detection' and a formula to suppress detection. The formula is using variables linked with the command group. When the use of the formula is deactivated (option 'breaker ...
It is not possible to complie a project with the HTML Web Engine Compiler, if one frame has a freely defined shape
Summary If a freely defined frame does exit in the project, the following error appears: "Freely definable frames are not supported. The frame and corresponding screens will not be available in the HTML Web Engine. " This error message also appears ...
When using the HTML Web Engine, loading the screens in a browser takes a very long time.
Summary Larger projects can take a very long time to load screens in the HTML Web Engine. This may cause the runtime to be unusable, if several screen switches cause the Web Engine to permanently load for several minutes. DescriptionLarger projects ...
In the HTML Web Engine, a string containing a semicolon is cut down to the prominent letters or numbers. All characters after the semicolon are ignored.
Summary If a string "1,234" is used in the HTML Web Engine, the string is cut down to "1", if the separation is realized with a dot ("1.234") the string "1.234" is displayed correctly. DescriptionIf a string "1,234" is used in the HTML Web Engine, ...
Under specific circumstances the DIALOGKBD screen is shown unexpectedly in the Runtime.
Summary When a user enters a column filter in a list via the DIALOGKBD screen, this always pops up a second time in the next user action if the list is still visible in the Runtime. DescriptionWhen a user enters a column filter in a list via the ...
In command screen the interlocking text from previous action is still displayed while new action waits on Select confirmation from PLC.
Summary In the time when the Command Processing is waiting on the Select confirmation from PLC, the interlocking message of the previous action is still visible in the control element 'Interlocking Text'. DescriptionIn the time when the Command ...
In zenon Network, if the command screen can't allocate the NET_SEL status bit and gets it later, then it will not refresh the bit.
Summary If response variable has already the status bit NET_SEL - "selected in zenon Network" - and the user opens the command screen, then he does not get the access and must wait until a user on another Network client finishes to operate this ...
Command Processing: no interlocking text when action fails at second stage, while at first stage there was no interlocking yet.
Summary Command Processing, two-stage action 'command': issue when at first stage (i.e. Select) the interlocking condition is OK, but at second stage (Execute) - not anymore. Then when user press button to execute - the action cancels automatically ...
It may happen that the authorization signature text is not logged in the chronologic event list in the Runtime.
Summary The Signature text may not be logged in the chronologic event list in the Runtime if the property "signature text editable" is disabled in the Editor. DescriptionThe Signature text may not be logged in the chronologic event list in the ...
It may happen that the context menu of elements properties shows empty entries in the Editor.
Summary It may happen that the context menu of element properties shows empty entries in the Editor. DescriptionIt may happen that the context menu of element properties shows empty entries in the Editor. Solution The issue has been fixed. Issue ...
The User name control element of the Login screen may not be updated in the Runtime.
Summary Although the login is successful, the User name control element of the Login screen may remain empty after a user enters the login name using the Keyboard screen in the Runtime. DescriptionAlthough the login is successful, the User name ...
IEC870 driver in serial communication (-101): when one connection is not reachable all the others do not communicate
Summary Conditions: IEC870 driver, serial communication (60870-5-101), multiple connections - to few PLCs. At the start of the Runtime, if one of the serial communication is broken (e.g. 3th), the driver cannot establish the communication with the ...
Under specific timing circumstances the OPC UA server in the process gateway does not correctly remove an online container in the runtime which may lead to a continued increase in resource consumption and finally resource exhaustion.
Summary The OPC UA server in the process gateway communicating with an OPC UA client that performs irregular and unexpected frequent requests may under specific timing conditions not succeed to successfully remove an online container in the runtime ...
An online container is created in the runtime by the OPC UA server that is not unique for its instance
Summary The OPC UA server in the process gateway dynamically creates an online container in the runtime when an OPC UA client creates a subscription in a session.The name of the subscription contains the subscription ID Multiple OPC UA clients ...
Writing a value through a .wpf element to an internal variable is not possible when authorization in the network is enabled and the system does not have the authorization token.
Summary When using a .wpf element, writing a value through the element to a local internal variable is not possible when network authorization is used and the system does not have the network token. Using other dynamic elements or using functions, ...
The OPC UA server may enter a deadlock state on closing the runtime under specific circumstances
Summary On closing the runtime with an OPC UA server running in the process gateway to which multiple OPC UA clients are communicating, the OPC UA server may enter a deadlock state while attempting to close the connections and clean up used objects. ...
The backup file of user administration may not be updated in the Runtime.
Summary The backup Password.cmp.old file of user administration may not be updated in the Runtime. DescriptionThe backup Password.cmp.old file of user administration may not be updated in the Runtime. Solution The Password.cmp.old file is now updated ...
The PROFINET controller in zenon logic shows unexpected behaviour when the length of IO and IOCS data exceeds the maximum size of 500 bytes or when either the option Do not wait until connect has been completed or Start despite disconnected slaves is checked.
Summary When using the PROFINET controller in zenon logic, the behaviour of the controller during runtime can be unexpected when the length of IO and IOCS data exceeds the maximum size of 500 bytes or when either the option Do not wait until connect ...
Variables of OPC2CLI32 driver get invalid when the OPC2CLI32 driver is started in Simulation - static mode and then switched to Hardware mode during runtime
Summary When starting the OPC2CLI32 driver in mode Simulation - static and then switching to mode Hardware during runtime, the variables of the OPC2CLI32 driver become invalid. Description When starting the OPC2CLI32 driver in mode Simulation - ...
The LON_32 driver unexpectedly stops working when opening the driver configuration of the LON_32 driver when using LonMaker 3.24
Summary When using LonMaker 3.24, the LON_32 driver unexpectedly stops working when opening the driver configuration of the LON_32 driver when using LonMaker 3.24. DescriptionWhen using LonMaker 3.24, the LON_32 driver unexpectedly stops working when ...
The Azure process gateway shall support configurable HTTP proxy credentials
Summary The Azure process gateway shall provide configurable HTTP proxy credentials. DescriptionThe Azure process gateway shall provide configurable HTTP proxy credentials. Solution This issue has been addressed by providing configurable HTTP proxy ...
With the S7TIA driver it should be possible to communicate with a PLC also without a TIA project.
Summary Solution The S7TIA driver shall communicate with a PLC also without a TIA project. Issue Number: 37563 Fixed on Date: 19.1.2017 Versions: 7.50 0 BUILD 34636
The 3S_V3 driver shall support an alternate IP address in order to provide redundant communication.
Summary In order to provide redundant communication of the 3S_V3 driver, the 3S_V3 driver shall support an alternate IP Address. DescriptionIn order to provide redundant communication of the 3S_V3 driver, the 3S_V3 driver shall support an alternate ...
A configurable initial baudrate shall be provided for the IEC62056 driver.
Summary It shall be possible to configure a initial baudrate for the IEC62056 driver. DescriptionIt shall be possible to configure a initial baudrate for the IEC62056 driver. Solution The initial baudrate has been added as a configurable parameter ...
When importing variables either from the PLC or from a XML symbol file of the 3S_V3 driver, variables with a name consisting of more than 128 characters shall not be imported.
Summary Variables of the 3S_V3 driver with a name consisting of more than 128 characters shall not be imported from a PLC or from a XML symbol file. DescriptionVariables of the 3S_V3 driver with a name consisting of more than 128 characters shall not ...
The S7TIA driver performs poorly with AGLink.dll v5.1.0.2
Summary When using AGLink.dll v5.1.0.2 the S7TIA driver performs poorly. DescriptionWhen using AGLink.dll v5.1.0.2 the S7TIA driver performs poorly. Solution This issue has been addressed by updating the AGLink.dll to v 5.1.0.9 Issue Number: 37156 ...
The selection lasso may not be drawn in the Runtime.
Summary The lasso may not be visible when selecting a screen area in the Runtime. DescriptionThe lasso may not be visible when selecting a screen area in the Runtime. Solution The issue has been resolved so that the lasso is now visible in the ...
VoIP call is not possible because of authorization issue.
Summary Some providers are not so flexible with the MC VoIP authorization management. It is possible that there are some providers which use for the "realm" not their domain name. DescriptionSome providers are not so flexible with the MC VoIP ...
Under specific circumstances the zenon runtime may unexpected closed when POP3 server did not work as expected.
Summary The issue happened when a SMTP or POP3 server did not send an opening message after opening the connection. DescriptionThe issue happened when a SMTP or POP3 server did not send an opening message after opening the connection. Solution The MC ...
Under specific circumstances user information may be lost in the Runtime.
Summary Powering off the runtime device may damage the password.cmp file and cause user information loss in the Runtime. DescriptionPowering off the runtime device may damage the password.cmp file and cause user information loss in the Runtime. ...
Extended Trend screen does not sort data in the StandBy server and Clinet runtime
Summary On StandBy and Client runtimes can't be displayed data in Extended Trend unsorted and sorted by timestamp. The option "Sort data" of the screen switch function to the Extended Trend screen is not working in the StandBy and Client runtime, so ...
Extended Trend doesn't show curves if aggregation data are evaluated in SQL database.
Summary In Extended Trens screen switch function are not show aggregation curves MIN, MAX and MW from SQL database after evaluation. DescriptionIn Extended Trens screen switch function are not show aggregation curves MIN, MAX and MW from SQL database ...