7.20
DNP3_TG driver: network interface configured for UDP listening port / TCP Dual Endoint port, is not taken over
Summary In the driver configuration of the DNP3_TG driver the network interface that can be configured for the UDP listening port or the TCP Dual Endpoint listening port, is not correctly taken over in the runtime. Instead the driver always opens a ...
DNP3_TG driver: Setting link status request interval to "0" results in constant link status requests being sent
Summary When the link status request interval (Keep Alive) is set to "0" in the driver configuration, the DNP3_TG driver in the runtime sends continuous link status request messages, rather than disabling link status requests Description When the ...
SQL evacuation failure with double entries in archive file
Summary The SQL evacuation stops if in the archive file are two identical values. Identical means same NameID same Value same Timestamp same Status. These entries could happen if in the archive configuration the option 'save process image during ...
3S_V3 driver maximum of 10 characters possible for node name
Summary When entering manually a node name in the driver connectiobn configuration, there is a maximum of 10 characters. Node names can have mor than 10 characters, eg. the automatic given name for PC based codesys PLC is the PC Name like ...
When IEC850 driver is configured to "Use Report-ID for RCB assignment" then it uses the globally configured TrgOps instead of the TrgOps per RCB
Summary Issue when the option "Use Report-ID for RCB assignment" in IEC61850 Client driver is active: then to enable a RCB the driver uses the globally configured options (e.g. TrgOps) and not the options configured for this particular RCB. Affected ...
When in Data Model of 850-Server the BRCB.rptID is empty then the IEC850 driver is not able to "Use Report-ID for RCB assignment" and is not storing EntryID to acquire buffered events after reconnect.
Summary According the IEC61850 Standard when RptID is empty then it means that it in Reports it will be the ObjectReference to RCB, e.g. "IEDNameLDInst/LLN0$BR$brcbST01". At the communication start or online browsing of available RCBs the IEC61850 ...
The webclient may close unexpectedly when moving a keyboard screen.
Summary When dragging the keyboard DIALOGKBD in internet explorer the webclient may produce an unhandled exception. Description When dragging the keyboard DIALOGKBD in internet explorer the webclient may produce an unhandled exception. Solution The ...
The editor may replace specific characters with a '?' character.
Summary The editor displays a question mark symbol '?' to replace Unicode arrow characters in reaction matrices and combined elements states. Description The editor displays a question mark symbol '?' to replace Unicode arrow characters in reaction ...
The WPF Sankey diagram may show an incorrect outline in the runtime.
Summary The WPF Sankey diagram may show an incorrect result when one or more of its variables change their values at the same moment this is being displayed in the runtime. Description The WPF Sankey diagram may show an incorrect result when one or ...
iec850 driver when receives time accuracy N, then uses as FractionOfSecond only N bits, but shall use N+1
Summary IEC61850 Client driver truncates all non-significant bits of received time stamp (t-attribute) from a 850-server with TimeQuality.TimeAccuracy <> 31 ('unspecified'). The driver treats the Time Accuracy value N as number of significant bits in ...
The runtime may terminate unexpectedly when opening a screen containing combined elements configured with an automatic line coloring function.
Summary The runtime may produce an unhandled exception when opening a screen containing a combined element with the automatic line coloring terminator function type but no variable linked. Description The runtime may produce an unhandled exception ...
The editor may fail to create runtime files for converted projects
Summary The editor may close unexpectedly or pop up an "unexpected file format" message when creating the runtime files in converted projects. Description The editor may close unexpectedly or pop up an "unexpected file format" message when creating ...
Some specific keyboard inputs may be executed twice in the HTML screen.
Summary When a Silverlight page is open in the HTML screen the keyboard inputs are routed twice so that the pressed key is executed two times. Description When a Silverlight page is open in the HTML screen the keyboard inputs are routed twice so that ...
The notepad screen may remove the content of text files opened in the runtime.
Summary The content of text files opened in the runtime using the notepad screen may be erased if the screen typ:edit element was added manually to the screen in the editor. Description The content of text files opened in the runtime using the ...
It is not possible to edit copied submenus in the editor.
Summary If a submenu within a context or main menu is copied in the editor using copy-paste it cannot be changed afterwards. Description If a submenu within a context or main menu is copied in the editor using copy-paste it cannot be changed ...
modifying tag values is possible in the tag selection dialog for control strategies
Summary In the Batch Control module in zenon editor it is possible to linke command tags to control strategies. In the dialog where you can select the tags it is actually possible to switch to edit mode and to modify the tags' values. The so edited ...
Analyzer Export Wizard for zenon Analyzer 2.10 hangs when loading data into the wizard
Summary When loading the zenon project into the Analyzer Export Wizard, the loading bar stopps on ~2/3. The zenon editor stopps working and must be closed (windows message) DescriptionWhen loading the zenon project into the Analyzer Export Wizard, ...
Inserting a WPF element in a non-standard screen in the editor, may result in the color of screen specific control elements to be displayed incorrectly in the runtime.
Summary When a WPF element is drawn in a non-standard screen in the runtime, the back color or font color of other screen specific control elements, like a combo-box in the alarm screen, may be incorrect. DescriptionWhen a WPF element is drawn in a ...
The sorting in the recipe value table in the Recipegroup Manager screen in the runtime is reset after a recipe is saved.
Summary When sorting for a specific column in the recipe value table in the Recipegroup Manager screen in the runtime, the sorting gets reset back to the default writing order when the recipe is saved. DescriptionWhen sorting for a specific column in ...
The sorting of the recipe value table in the Recipegroup Manager screen in the runtime changes unexpectedly under specific circumstances
Summary When selecting a recipe variable in the recipe value table in the Recipegroup Manager screen in the runtime and executing e.g. the screen specific function "read selected value", then change the sorting on a different column and executing the ...
The OPCUA32 client driver does not communicate on Windows CE devices
Summary On Windows CE devices, the OPCUA32 client driver does not startup properly and does not communicate with the configured OPC UA server. The error logs in the diagnosis server contain the following error: "Failed to load client certificate" ... ...
The user that is stored as the user that created or last modified the Recipegroup Manager is not correct when the recipe is created or changed on a runtime client
Summary The user that is stored as the user that created or lastmodified a Recipegroup Manager is not the correct user from the runtime client where the recipe was modified but the user that was logged in on the runtime server at the time the recipe ...
The OPCUA32 client driver does not resume communication after short network connection loss under specific circumstances.
Summary When the network connection between the OPCUA32 client driver and the OPC UA server is lost for a specific short period where TCP retransmits may still reach the server after the connection is established and where the connection loss is long ...
The OPCUA32 client driver causes long (~40s) delays during reload of the runtime and closing of the runtime under specific circumstances
Summary When the runtime running a a project using the OPC UA client driver in combination with a specific OPC UA server is closed, the OPCUA32 client driver delays the close of the runtime. With the specific OPC UA server there may also be a long ...
It may occur that some combobox elements are not shown in the runtime.
Summary In Windows CE 6.0 x86 platforms the Time/Lot Filter screen combobox control elements may not be visible in the runtime. DescriptionIn Windows CE 6.0 x86 platforms the Time/Lot Filter screen combobox control elements may not be visible in the ...
The editor may close unexpectedly when inserting a curve in a trend element.
Summary If a trend element is inserted without any variable selected, by cancel the variable selection dialog, when adding a new curve via the Curves context menu and cancelling again the variable selection dialog, the editor may close unexpectedly ...
It may not be possible to restore a project backup in the editor.
Summary A project backup may not be restored when the project was previously converted to a newer editor version. DescriptionA project backup may not be restored when the project was previously converted to a newer editor version. Solution An issue ...
S7TIA driver cannot import projects from TIA13 Portal which were created for a S7-1512 CPU
Summary S7TIA driver cannot import projects from TIA13 Portal which were created for a S7-1512 CPU DescriptionS7TIA driver cannot import projects from TIA13 Portal which were created for a S7-1512 CPU Solution S7TIA Driver now handles the import of ...
Cyrillic characters in string variables of the stratonNG driver are not shown correctly in the zenon Logic runtime and zenon runtime
Summary Cyrillic characters in string variables of the stratonNG driver are not shown correctly in the zenon Logic runtime and zenon runtime DescriptionCyrillic characters in string variables of the stratonNG driver are not shown correctly in the ...
S7TCP32 only receives Alarm-8 during driver initialization
Summary Alarm-8 Messages are only received by zenon during the initialization of the S7TCP32 Driver (e. g. when stopping and starting the S7TCP32 driver or when starting the zenon runtime) DescriptionAlarm-8 Messages are only received by zenon during ...
At the zenon Runtime some MDI elements with scrollbars in various screen types can suppress the execution of a time function.
Summary When holding the scrollbar with the left mouse button or a gesture if a touch display is used provokes this effect. Scrolling by mouse wheel can trigger this behavior too. DescriptionWhen holding the scrollbar with the left mouse button ...
Large attachments like JPG or PDF cannot be sent with SMTP email.
Summary Emails without attachment or with small attachments can be sent, emails with large attachments cannot be sent. DescriptionEmails without attachment or with small attachments can be sent, emails with large attachments cannot be sent. Solution ...
Under specific circumstances the set value action cannot be executed using the SETVALUEKBD keyboard in the runtime.
Summary The SETVALUEKBD keyboard may block incorrectly the execution of the set value action in the runtime when the target variable uses linear value adjustment together with unit conversion. DescriptionThe SETVALUEKBD keyboard may block incorrectly ...
Under specific circumstances the XML-import of alarm areas result in a wrong class linking in the editor.
Summary It may happen that the XML-import of alarm areas between two sub projects result in a wrong alarm class linking in the editor, so that the alarm areas class linking in the target sub project are shifted to the next alarm class, previously ...
It may occur that the zoom factor is not synchronized between normal and full screen view in the editor.
Summary The zoom factor combo box in the editor may not be updated when switching between the normal and the full screen modes in the editor. DescriptionThe zoom factor combo box in the editor may not be updated when switching between the normal and ...
The screen frame title bar may display a generic application icon in the runtime.
Summary The screen frame title bar may show a generic application icon instead of the OEM runtime icon. DescriptionThe screen frame title bar may show a generic application icon instead of the OEM runtime icon. Solution It is now loaded the correct ...
Lot filter with a filter on archive does not work with a lot filter screen.
Summary When a screen switch function to an extended trend screen is configured at the zenon Runtime to show a lot filtering it is not shown all lot data. DescriptionWhen a screen switch function to an extended trend screen is configured at the ...
It could happen that the Filter Button of the screen specific function of the zenon Report Generator at the zenon Runtime just works once.
Summary At the zenon Report Generator the screen-specific function "Filter..." only works once and when trying to filter again it only refreshes the screen with the previously selected filter. DescriptionAt the zenon Report Generator the ...
It should be possible to open the DIALOGKBD screen relatively to the position of the login screen in the runtime.
Summary Unlike the SETVALUEKBD and the SETSTRINGKBD, the DIALOGKBD screen does not use relative positioning to the calling screen or element, but the coordinates of the frame linked, so that in specific circumstances the element to which is being ...
Under specific circumstances, special keyboard characters are not recognized in the runtime.
Summary It may occur that Silverlight pages with special keyboard characters are not correctly recognized in the HTML screen in the runtime. DescriptionIt may occur that Silverlight pages with special keyboard characters are not correctly recognized ...