7.20
unexpected shutdown of Runtime when expanding the PFS tree
Summary When using the PFS (Production and Facility Scheduler) it may happen in rare cases that the runtime stops working unexpectedy when expanding the PFS tree on a client. Description When using the PFS (Production and Facility Scheduler) it may ...
The change of supply area name in the Load Management is not correctly handled in reload.
Summary When changing / renaming supply area name in the Load Management and reload the project, the Runtime may exits unexpectedly Description When changing / renaming supply area name in the Load Management and reload the project, the Runtime may ...
Renaming a schedule in the PFS may result in an unexpected shutdown of the Runtime
Summary The PFS (Production and Facility Scheduler) may be used to maintain schedules. You may also rename schedules. However, when doing this on a client PC it may happen in rare cases, that the runtime stops working when reloading RGM data from the ...
Releasing the property for the variable of a bargraph element in a symbol does not consider the limits
Summary When a bargraph element is used in a symbol and the variable property is released, the display limits configured at the bargraph element in the symbol are not taken over. Instead the limits of the variable are taken over. When the properties ...
When configuring a C compiler for a driver simulation project the driver stops working when starting the runtime
Summary When configuring a C compiler for a driver simulation project the driver stops working when starting the runtime When starting the runtime the driver tries to register itself and seems then to stop immediately. When configuring compiler ...
LogixODVA: It is not possible to write on large Blockarrays
Summary It is not possible to write on big blockarrays, if the PLC uses an EN2T/D communication processor. Description It is not possible to write on big blockarrays, if the PLC uses an EN2T/D communication processor. Solution Added additional ...
Elements dissappear in the runtime after a screen switch under specific circumstances
Summary Under specific circumstances when using elements drawn in GDI compatibility mode like WMF or EMF graphics, other elements may not be displayed correctly anymore after a screen switch function. Description Under specific circumstances when ...
Under specific circumstances when resolving a symbol, elements in the symbol change their position
Summary When resolving an element in a screen in the editor, under specific circumstances the elements in the element group change their position Description When resolving an element in a screen in the editor, under specific circumstances the ...
PSS32 driver is not working under WinCE 6
Summary PSS32 driver is not working under WinCE 6. The Message "Mapping GPIO is not possible" appears at the Runtime start. Description PSS32 driver is not working under WinCE 6. The Message "Mapping GPIO is not possible" appears at the Runtime ...
Input elements in the edit user screen are not considered with "set focus" functions
Summary Input elements in the screen type for editing users cannot all be reached through set focus functions in the runtime. Keyboard operation using "tab" (set focus to the right or bottom) does not work correctly Description Input elements in the ...
ALC compilation warning is not processing correctly non-existing symbols
Summary When a screen using Automatic Line Coloring contains a symbol which is no more present in the symbol library the Editor displays linked symbol as "the symbol could not found in library" . By project compilation there is a warning in output ...
Combined elements which are included in symbols cannot be used for ALC Aliases
Summary If a symbol contains a line it can be used for an ALC Alias, a combi-element – cannot (is not present on the list). DescriptionIf a symbol contains a line it can be used for an ALC Alias, a combi-element – cannot (is not present on the list). ...
text filter of the CEL may not find all expected CEL entries
Summary When applying a text filter to the CEL and deactivating the option "words do not need to be in the text completely", the filter result may not contain all CEL entries that match the filter string, when the filter string appears twice in the ...
Under specific circumstances control elements in the alarm message list filter screen are not displayed
Summary Under specific circumstances the time filter combobox element is not displayed in the alarm message list filter screen Description Under specific circumstances the time filter combobox element is not displayed in the alarm message list filter ...
When the API is used to write archive values with future timestamps, the data cannot be shown with timefilters other than "No timefilter"
Summary When the API is used to write archive values with future timestamps, the data cannot be shown with timefilters other than "No timefilter". If a specific time filter is set, no data is shown in a trend/report/archive revision screen. ...
Writing a string variable of the straton_NG driver in the zenon runtime with a length of 247 characters or more fails and prevents further writes to the string variable from the zenon runtime until after a restart of the runtime
Summary When a string variable in zenon (lenght 255) from the straton_ng driver is written in the runtime (string lenght in zenon logic 255), writing 246 characters still works OK. However writing 247 characters is not accepted (string is not updated ...
AML does not give possibility to sort by measuring unit
Summary Alarm Message List cannot be sorted by measuring unit of variable. Description Alarm Message List cannot be sorted by measuring unit of variable. Solution Issue was addressed in sorting in AML list Information Issue Number: 34429 Fixed on ...
zooming the trend in the extended trend screen using multi-touch zoom gestures does not work correctly
Summary Zooming the trend using two fingers multi-touch gestures no longer works in the runtime. Instead of zooming the trend in the extended trend screen, the trend screen itself is zoomed. Description Zooming the trend using two fingers multi-touch ...
In CEL the filter on variable name is not working correctly with option "Always include system messages"
Summary In Chronological Even List the filter on variable name displays all variables when option "always include system messages" is also active. When "always include system messages" is deactivated – the filter works correctly. DescriptionIn ...
iec850 driver in Abort procedure uses too long timeout when server does not react correctly
Summary In IEC61850 (client) driver please reduce in Abort procedure the timeout value 1s introduced by #181506 - to 100ms. Currently there are on the market popular server stacks reacting on Abort with "old-fashion", not Standard-conform, response ...
The commands screen created from template may contain a useless close red button in the editor and runtime.
Summary The energy-complete screen template adds incorrectly a red close button to the commands screen. Description The energy-complete screen template adds incorrectly a red close button to the commands screen. Solution The screen commands ...
Configurable originator in iec870 driver introduced for zenon 7.50 shall be available in 7.20 too
Summary New configuration settings "Originator address" introduced in IEC60870 (Master) driver for zenon version 7.50 should be also available in version 7.20. Description New configuration settings "Originator address" introduced in IEC60870 ...
In IEC870Slave the event buffering shall be maintained also while connected with a Master
Summary The IEC 60870 Slave - zenon Process Gateway and straton/Logic I/O driver - shall maintain event buffer while connected with a Master; and not start only when detects the loss of connection. Slave should prevent the loss of data in the period ...
IEC 61850 Client driver in Logic should have configuration settings BufTm, IntgPd, OptFlds like zenon iec850 driver has
Summary zenon version 7.20 has introduced in zenon IEC61850 (client) driver new configuration settings, but not in the Client driver in straton/Logic. The driver configuration RCB settings: Buffer Time, Integrity Period and Optional Fields should be ...
It may occur that standard users must set the password at every login in the runtime.
Summary If an administrator creates or sets the password of a standard user, that user must change its password at every login in the runtime. Description If an administrator creates or sets the password of a standard user, that user must change its ...
The HTML screen may not recognize keyboard inputs in the runtime.
Summary The keyboard inputs are not accepted by the HTML screen in the runtime when a web page delivers Silverlight content embedded. Description The keyboard inputs are not accepted by the HTML screen in the runtime when a web page delivers ...
The system driver variable "last lot selected" may not be updated in the runtime.
Summary When filtering to a lot using the time/lot screen the system driver variable "last lot selected" is not updated in the runtime. Description When filtering to a lot using the time/lot screen the system driver variable "last lot selected" is ...
It should be possible to import in the editor S7 data blocks from the TIA Portal 13 SP1 or higher versions.
Summary The import S7 project wizard in the editor could not read and import data blocks from a S7 project developed in the TIA Portal 13 SP1 or higher versions. Description The import S7 project wizard in the editor could not read and import data ...
Under specific circumstances the message control substitute person dialog does not show the users list in the webclient
Summary It may be not possible to assign a substitute person for message control when opening the dialog via the edit user screen specific function "select substitute person" as the users list is missing in the webclient. DescriptionIt may be not ...
The error message The read user information is invalid! The project <'project-name'> is not loading! appears on a multiuser environment.
Summary The error message The read user information is invalid! The project <'project-name'> is not loading! , which appears after restarting the zenon Editor is related to the istributed Engineering module (multi-user). It is only in combination ...
Distributed Engineering. It seems that the zenon Editor gets block on a multiuser project.
Summary The zenon Editor may needs few second when a multiuser client is "checking in", "checking out" or "delete modification" at the screen knot of the Project Manager. For that time the zenon Editor is not operable. Description The zenon Editor ...
Distributed Engineering. Under specific circumstance the zenon Editor is no more operable.
Summary When creating a multiuser project and drag&hover symbol from the symbol library over the node symbol library leads to a deadlock. For example the message box Element "Active project Symbol libary" is write protected! Enable changes? appears ...
Multi-Touch issue with Windows 8 and the digital keyboard.
Summary Under specific circumstance the user defined keyboard "DIALOGKBD" will not work for dialogues which are shown in a specific screen type for example "Chronological Event List" or "Recipegroup Manager". When a new zenon project was created and ...
Keywords are not translated via the language table.
Summary The string Creating list... or Liste wird erzeugt... will be shown when the CEL/AML is being populated isn't translated via the language table. Description The string Creating list... or Liste wird erzeugt... will be shown when the ...
Cross reference list did not support information of the SAP module.
Summary It was not possible to get any parameters of the SAP module at the cross reference list. For example, it was not possible to find out which variables are being used at the SAP interface with the cross reference list. Description It was not ...
The zenon Editor stops working when selecting and deleting a structured data type element.
Summary When a structured data type with associated variable was created and the variable was open in a new window via the project tree – right mouse click on the variable – and deleted afterwards the item of the structured data type, then the zenon ...
Screen – Execution - Start function. Removing a function link through the "no selection" button in the function selection dialog for a sub-project, that is not loaded, leaves a dummy link to the project.
Summary Removing a function link at e.g. the start function of a screen, through the "no selection" button in the "function selection dialog", where the function is the function of a sub project and the sub project is not loaded, leaves a dummy link ...
zenon Editor close unexpected, if open & close the monitor configuration and click on a screen in the list of screens.
Summary When opening the monitor configuration and then click on a screen in the list of the screens (project tree) the zenon Editor exit unexpected. In detail this can occur, when firstly open the properties of the zenon project and select/click on ...
New functionality implemented for the DNP3_TG driver: Subset Level 4+ master including DNP3 file transfer
Summary The DNP3_TG driver is a Subset level 2 master and does not support DNP file transfer Description The DNP3_TG driver is a Subset level 2 master and does not support DNP file transfer Solution The DNP3_TG driver has been enhanced with ...
DNP3_TG driver as DNP3 master with dual endpoint does not correctly accept unsolicited responses from an outstation initiated connection.
Summary With a DNP3_TG driver configured for use with a dual endpoint, after the master initially established a connection and closed the connection again due to inactivity after the idle timeout, an outstation can successfully connect to the ...