Removing a variable at the "screen with index" function does not correctly update the dialog
Summary When for a function "screen with index" in the configuration the variable selection dialog is called and the variable is removed via the "no selection" button, the dialog still shows the previously linked variable. Description When for a ...
The zenStartupMgr service does not log an error message in the Windows Application Event Log when a process it started could not be terminated.
Summary When the zenStartupMgr service is stopped, it terminates all applications it started in the reverse order. If process is no longer running, there is no message in the Windows Event Log on stopping the service that this application could not ...
ETM: the cursor output list only shows the amount of curves which were active when switching to the ETM screen. When more curves are activated / deactivated the cursor output list does not show a proper amount of curves and wrong values.
Summary The cursor output list always shows the amount of curves which were set active in the screen switch function. When curves are activated / deactivated in the ETM screen the output list is refreshed but always shows the same amount of curves. ...
straton RT: start via console does not support "-" and "/" as parameter
Summary if stratonRT.exe is called via console, it has been possible to add parameters with "-" or "/" (e.g. -PATH="C:\..."). It is not anymore possible to use the - and / character Description if stratonRT.exe is called via console, it has been ...
The status icon of a phase in Batch Control does not update correctly when a communication error is acknowledged and the phase state is aborting.
Summary When a communication error is acknowledged in Batch Control and the phase state is aborting, the acknowledgement of the communication error is not shown correctly at the phase status icon and the tooltip. Description When a communication ...
When the formula dialog for a transition in a PFC recipe in the Batch Control module in the runtime is closed with OK, the recipe is marked as modified, even though no change was made.
Summary When editing the condition formula for a transition object in a PFC recipe in a Batch Control screen in the runtime, the PFC recipe is marked as "modified", indicated by the "*" character in the open tab, even though no changes were made in ...
The 32 bit editor stops respoding under specific circumstances on creating a Recipegroup Manager function, and may display an error "Encountered an improper argument"
Summary When creating a new function "Recipegroupmanager" and selecting the type "Change recipe state", without any further selection of recipe groups or recipes, the editor may stop responding and display an error message: "Encountered an improper ...
The description of the control strategy of a phase in the Batch Control module in the runtime is not translated via Language Change.
Summary When a keyword is used for Language Change for the description of a Control Strategy of a Phase in the Batch Control module, this description is not translated in the Runtime via the Language Change function. Instead the keyword is shown. ...
The status icon of an operation in the Batch Control module in the Runtime is displayed incorrectly in a duplicated recipe under specific circumstances.
Summary The icon for an operation in the Batch Control module in the Runtime is displayed incorrectly as "running" in a duplicated recipe, when the original running recipe was restored from an image after the runtime was closed and restarted. ...
The icon in the toolbar and the context menu in the Editor for replacing links at a parameter in the Batch Control Module is incorrect.
Summary The icon in the toolbar and the context menu in the Editor for replacing links at a parameter in the Batch Control Module is incorrect. The same icon should be used for replacing links in other modules in the zenon editor. Description The ...
An "out of memory" message may appear under specific circumstances when verifying a Batch Control recipe.
Summary Under specific circumstances an error message "out of memory" may appear when validating a Batch Control Recipe in the runtime that uses (larger) operations. Description Under specific circumstances an error message "out of memory" may appear ...
Under specific circumstance the flashing of the Glow Effect weren't displayed correctly.
Summary When a variable was created with limits and an attribute flashing was also linked to it, at the zenon Runtime the blink effect were not displayed correctly. DescriptionWhen a variable was created with limits and an attribute flashing was ...
Under specific circumstance the indicating element was not working correctly.
Summary When a shadow was set on an indicated instrument and the project was started with DirectX the indicator was not pointed at the current value. DescriptionWhen a shadow was set on an indicated instrument and the project was started with DirectX ...
Under specific circumstance removing of linked variable is not working correctly.
Summary When a project was compiled it wasn't possible to delete the variable for dynamic coloring with backspace and enter. DescriptionWhen a project was compiled it wasn't possible to delete the variable for dynamic coloring with backspace and ...
Under specific circumstance the project name change doesn't apply to VBA Editor.
Summary When at the zenon Editor a project name was changed and the project also includes VBA code, after restarted the zenon Editor few code lines of the VBA code were lost. DescriptionWhen at the zenon Editor a project name was changed and the ...
Under specific circumstance the status bit naming doesn't apply to zenon Editor Dialogues.
Summary When a user adjusts a status bit at the project.ini, the bit naming doesn't apply to the zenon Editor Dialogue for example the mask calculation of aggregated archives has not been updated. DescriptionWhen a user adjusts a status bit at the ...
Under specific circumstance the decimal places were set wrong at the value calculation of variables.
Summary In the value calculation of variables it is possible to set the amount of decimal places. When a user set amount that values negative for archive and positive for archive should have the appointed decimal places. This was not working ...
The Commands screen control elements "Value response variable" and "Value action variable" should display Limit texts.
Summary The Limit texts from response and action variables – defined via variable limits or reaction matrix states – should be displayed on "Value response variable" and "Value action variable" Commands screen control elements, respectively. ...
The function selection dialog in the editor does not respond anymore under specific circumstances.
Summary It appears as if the zenon editor has stopped responding. The buttons in the function selection dialog no longer react on mouse clicks. Right clicking in the function selection dialog displays the context menu of the detailview behind the ...
The editor closes unexpectedly under specific circumstances when changing the datatype of an array variable.
Summary When structure elements of a structure datatype are deleted and the datatype of an array variable, that was based on the structure datatype, is changed, the editor closes with an unhandled exception. Description When structure elements of a ...
Batchmanager() can not be used in VSTA on a Webclient
Summary When using VSTA on a webclient, this.batchmanager() and its properties, methods and events are not available. Description When using VSTA on a webclient, this.batchmanager() and its properties, methods and events are not available. Solution ...
In a specific case the zenon runtime may close unexpectedly when opening a Variable diagnosis screen.
Summary If a project is engineered in zenon 7.10 editor and runtime files are compiled for an earlier zenon version, the targeted zenon runtime may suddenly close when opening a Variable diagnosis screen containing variables to display. If runtime ...
A specific filter defined at the screen switch function to the RGM screen in th 64 bit zenon editor is not saved
Summary When defining a recipe filter for recipe status or recipe version in the screen switch function for the RGM screen in the 64 bit editor, the filter settings are accepted without an error message however not saved. Description When defining a ...
"Workspace save as" in the zenon editor resets values of recipe variables from other projects to "0" in all Recipegroup Manager recipes in all projects
Summary When exeuting "workspace save as" in order to create a copy of the workspace including all projects, the recipes that use recipe variables from other projects have the values for those variables set to "0" in the copied projects. Variables ...
ALC Alias gives in the selection list elements of all types instead only the same as current element.
Summary ALC Alias only works between elements of the same screen element type: Combined element to Combined element, wire (Line / Polyline / Pipe) to wire. But the selection list for Combined element shows also Line / Polyline / Pipe and vice versa. ...
In the zenon network the user name for "authorization on new computer" entry in CEL is taken from user on process Server
Summary In the zenon Network when a user logs in on a client the entry "authorization on new computer" comes into CEL. In this entry the user name is taken from the user currently logged-in on process Server and not from user logging-in on client. ...
IEC850 driver does not log any hints when is not trying to enable any configured report
Summary When IEC61850 Client is not trying to enable any configured report from 'RCB assignment' - because e.g. small mistake in hostname, there is no information in log. Thus it is very hard for user to find the reason why configured RCBs are not ...
Removing a variable from the configured points list in the DNP3 process gateway does not add back the variable to the selection list
Summary When in the DNP3 proces gateway configuration a variable is removed from the list of configured points, the variable is not shown in the list of available variables. Per definition a zenon variable ca only be used once as a point in the DNP3 ...
Point specific setting for event handling in the DNP3 process gateway is not correctly taken in account
Summary In the DNP3 process gateway, event settings can be configured for object groups. Either sequence of events (SOE) or the latest value only. Also for each point individually, event settings can be configured. Either default (taken from the ...
IEC870 driver: redundancy according to IEC60870-5-104 Edition 2 can lead to not acknowledged frames
Summary During the redundancy switch between primary and secondary IP in IEC60870 driver (Master) - according procedure introduced by Edition 2 of the IEC60870-5-104 Standard - the slave can still send some frames. But when the procedure starts - ...
Error messages "Exception in Wnd..." and "Encountered an improper argument" appear in the runtime in the Recipegroup Manager screen under specific circumstances.
Summary When in a Recipegroup Manager screen the recipe status list is displayed and no recipe stati have actually been defined, two error message appear on saving a recipe in the Recipegroup Manager screen. The recipe itself is saved correctly. The ...
wrong colors in Batch control recipes
Summary In some situations it can happen that batch control PFC recipes are displayed with wrong grid color when the grid color was modified manually. Description In some situations it can happen that batch control PFC recipes are displayed with ...
The System Information Collector dos not provide metadata of the file 'cdhelper.dll'
Summary Even though the file 'cdhelper.dll' is being displayed in files > Scada > common files > startup, no metadata do this file is provided. Description Even though the file 'cdhelper.dll' is being displayed in files > Scada > common files > ...
SIC does not show a Web Client 7.11 installation
Summary In the "Versions" section SIC lists the Webclient installations. However, a Webclient 7.11 installation is ignored and will not be displayed. Description In the "Versions" section SIC lists the Webclient installations. However, a Webclient ...
The System Information Collector's temporary folder will never be deleted
Summary The System Information Collector extracts the content of a SIC-Log into the temp folder, when the Log is opened. The extracted files remain there until they are overwritten by the System Information Collector or manually deleted. This, ...
System Information Collector provides incorrect information about Registry entries
Summary On 64 bit operating systems the System Information Collector may store incorrect information in Registry > COPA-DATA > DataDir. Description On 64 bit operating systems the System Information Collector may store incorrect information in ...
the System Information Collector can only display latin script characters
Summary The System Information Collector has the limitation that it is not capable of displaying alphabets other than Latin script. Description The System Information Collector has the limitation that it is not capable of displaying alphabets other ...
Under special circumstances System Information Collector closes unexpectedly while scanning
Summary Under special circumstances it may hapen that SIC closes unexpectedly and without any message when performing a scan. Description Under special circumstances it may hapen that SIC closes unexpectedly and without any message when performing a ...
SQL connection error descriptions are not displayed when opening a saved SIC file in the System Information Collector
Summary After a scan with the System Information Collector, it may provide detailed information about the reason for a SQL connection issue. However, after storing the SIC file and opening it again, these details are lost. Description After a scan ...
No logging for failed maintenance messages
Summary When maintenance reports are used at the SAP Interface but creating the maintenance report in SAP fails (e.g. because of incorrect configuration), the log file does not provide information about this. Description When maintenance reports are ...