7.10
Windows CE device does not display historic data in AML
Summary Windows CE device does not display historic data in Alarm Message List, it displays "Seek failed" error message instead. Description Windows CE device does not display historic data in Alarm Message List, it displays "Seek failed" error ...
When exporting reaction matrices that have been created over the API, the editor stops responding
Summary When exporting reaction matrices that have been created over the API, the editor stops responding. Description When exporting reaction matrices that have been created over the API, the editor stops responding. Solution An issue has been ...
Recipegroup Manager Datasets for the report viewer use an incorrect datatype for some of the fields
Summary The existing dataset templates RGMRecipe1 and RGMValues1 use incorrect datatypes for some of the fields. This causes an error message when the datasets are duplicated in a report on pasting the query. Description The existing dataset ...
The VSTA multi-touch gesture "HOLD (mouse)" is not generating an event in the runtime
Summary The VSTA multi-touch gesture "HOLD (mouse)" is not generating an event in the runtime Description The VSTA multi-touch gesture "HOLD (mouse)" is not generating an event in the runtime Solution Due to an incompatibility with zenon multi-touch ...
PFS switching points get corrupted.
Summary From a certain moment on PFS switching points disappear after creation and also existing ones disappear. Description From a certain moment on PFS switching points disappear after creation and also existing ones disappear. Solution An overflow ...
Under specific circumstances some screen elements are not visible in a CE runtime.
Summary When using the backward compatibility for the runtime 6.22 SP1 the pipes and polylines screen elements may not be visible in the CE runtime. Description When using the backward compatibility for the runtime 6.22 SP1 the pipes and polylines ...
Distributed Engineering. Alarm Areas linked to an Equipment Model get lost after synchronization.
Summary At the zenon Editor (x86 & x64) with a multiuser global and standard project, alarm areas in the standard are lost after synchronization if they are linked to a global equipment group. Description At the zenon Editor (x86 & x64) with a ...
zenon Editor close when creating zenon Runtime files for 6.20 SP4.
Summary When selecting "Create files for: 6.20 SP4" at the zenon Editor and start to convert, after a couple of minutes – time depends on the project size - zenon Editor stops working and closes automatically. DescriptionWhen selecting "Create files ...
zenon Runtime close unexpected, when the property "Flash freq." was set to zero.
Summary When the project settings at the properties – "Graphical design -> Runtime general -> Flash freq. [tenth sec]" is set to "0" and the project was saved and compiled the zenon Runtime cannot be executed as await. The zenon Runtime will close ...
zenon runtime control crash under certain circumstances.
Summary If the zenon runtime control is used in an independend form like within a VBA form in Excel, it crashes. Description If the zenon runtime control is used in an independend form like within a VBA form in Excel, it crashes. Solution This issue ...
LON32 driver closes when try to change the driversettings without correct 3rd party software
Summary If the proper software (LON maker) is not installed it may happen that the driver stops unexpected when try to configure the driver settings. Description If the proper software (LON maker) is not installed it may happen that the driver stops ...
When browsing the LON database the LON32 driver stops
Summary When trying to brows the LON database in the extended variable properties for a variable based on LON32 driver, the driver stops working. Description When trying to brows the LON database in the extended variable properties for a variable ...
The change password dialog may not allow to set up a new user password in the runtime.
Summary The change password dialog does not allow setting a new user password in the runtime when it is issued by a temporary login and another user is currently logged in. This occurs as the change password dialog targets the current logged in user ...
When an element is added to a symbol by using the API, the resulting position/size of the added element is incorrectly
Summary When trying to add elements to a symbol, there is a position offset added to elements which results in a wrong position/size. Setting element positions to 0/0 before adding element to symbol does not fix the problem. This may also results in ...
iec850 driver does not set T_STD bit (bit 30) at variables with timestamp from t-attribute (T_EXTERN)
Summary IEC61850 Client driver does not set the T_STD bit at the zenon variables getting external timestamp - from t-attribute (variables with FC= ST or MX, e.g. */stVal[ST]). The driver uses correctly T_STD bit but only by T_INTERN timestamps, not ...
The 64-bit runtime may close unexpectedly when opening a screen with embedded symbols.
Summary The 64-bit the runtime may produce an unhandled exception on opening a screen having embedded symbols with dynamic X/Y positions. Description The 64-bit the runtime may produce an unhandled exception on opening a screen having embedded ...
zenon Editor AutoCAD vector graphics import fails.
Summary At the zenon Editor 32 & 64 Bit version an AutoCAD vector graphics (*.dxf) files cannot be loaded. An error message appeared on selecting the *.dxf stating "Can't load import file". DescriptionAt the zenon Editor 32 & 64 Bit version an ...
The zenon logic FTP function block does not send files if their names contain 5XX (e. g. 500,510,501).
Summary The zenon logic FTP function block does not send files with the PUT command if the file names contain 5XX (e. g. 500,510,501). As a result the FTP server creates a file with that name but with size of 0KB. The function block gives back the ...
GOOSE subscriber is not updating the timestamp received from the GOOSE publisher
Summary zenon Logic I/O driver ‘IEC 61850 Server with GOOSE’ as Subscriber is not updating timestamp - the value of t-variable – when received in GOOSE message from a Publisher. In earlier builds of 7.10 and versions was OK. Descriptionzenon Logic ...
GOOSE Publisher: missing 802.1Q field in GOOSE header when VLAN ID=0
Summary zenon Logic I/O driver ‘IEC 61850 Server with GOOSE’ as Publisher places 802.1Q field into GOOSE header only when VLAN ID > 0. Even when VID=0 the driver should include the 802.1Q, in order to set the message priority - if priority is ...
In zenon 7.11 it should be possible to enter an ip address as well as a hostname as string for the Network Connection of the S7TCP Driver instead of having four numerical fields for the ip address as before.
Summary When a hostname entered for the Network Connection of the S7TCP driver can`t be resolved, the given string will be interpreted as IPV4 address. DescriptionWhen a hostname entered for the Network Connection of the S7TCP driver can`t be ...
The logging for the KUKA Driver should be enhanced.
Summary In the diagviewer SetInfo, Cancel and OnSetInfo of the KUKA Driver will not be logged. DescriptionIn the diagviewer SetInfo, Cancel and OnSetInfo of the KUKA Driver will not be logged. Solution This issue has been addressed by adding logging ...
KUKA32 Driver. Variables of driver object type 'KUKA System Variable' do not support dynamic communication names.
Summary The usage of dynamic communication names with variables of Driver object type KUKA System Variable of the KUKA32 Driver does not work correct. Instead of the correct values chinese like characters are shown. DescriptionThe usage of dynamic ...
PHOENIX32 Driver should support variable addressing via symbolic address
Summary PHOENIX32 Driver should Support variable addressing via symbolic address in addition to addressing via variable name. DescriptionPHOENIX32 Driver should Support variable addressing via symbolic address in addition to addressing via variable ...
Performing "online change" in zenon logic after adding variables to zenon with activated option "externally visible" and reload of the zenon runtime the variables in zenon are not linked correctly to the corresponding variables in zenon logic. As a result, the added variables don`t have a value in zenon logic.
Summary When zenon runtime is active, adding variables in zenon with option "externally visible" active and having also enabled "On Line Change" in zenon logic, the values in zenon logic corresponding to the added variables in zenon do not have a ...
The option "Offset 1" should be available for the MODBUS_ENERGY driver
Summary The option "Offset 1" is already available for the MODRTU32 Driver and should also be available for the MODBUS_ENERGY Driver. DescriptionThe option "Offset 1" is already available for the MODRTU32 Driver and should also be available for the ...
The connect to modem validation mechanism of zenon sets wrong SMSC number in the SIM card settings and sending of SMS is not possible over that SIM card.
Summary If the field:"Number of SMS center" is empty, the connect to modem validation mechanism of zenon sets a wrong number in the SIM card settings and sending of SMS is not possible over that SIM Card. DescriptionIf the field:"Number of SMS ...
zenon Process Gateway ICCP (TASE.2) stops working during association with particular ICCP test client.
Summary Issue during try to associate with Iron IEC 60870-6 ICCP/Tase2 Test Tool from Triangle MicroWorks: zenon Process Gateway stops working. It happens after the Test Tool (remote ICCP client) sends frame with malformed ASN.1 stream. ...
When selecting the tab Offline MIB list of the SNMPNG32 driver without having any agents configured under tab SNMP Agents, the SNMPNG32 driver stops working.
Summary The SNMPNG32 driver stops working when selecting the tab Offline MIB list of the SNMPNG32 driver without having any agents configured under tab SNMP Agents. DescriptionThe SNMPNG32 driver stops working when selecting the tab Offline MIB list ...
OMR_FINS driver does not read/write strings correctly from all memory areas
Summary OMR_FINS driver does not read/write strings correctly from all memory Areas. Behavior is different depending on PLC type. DescriptionOMR_FINS driver does not read/write strings correctly from all memory Areas. Behavior is different depending ...
ActiveX control for zenon Runtime ends unexpectedly when inserted in a VBA form (Excel).
Summary ActiveX control for zenon Runtime ends unexpectedly when inserted in a VBA form (Excel). DescriptionActiveX control for zenon Runtime ends unexpectedly when inserted in a VBA form (Excel). Solution Issue was addressed in license check for ...
zenon Logic Workbench and Runtime parameters for Target Host and Target Port cannot be correctly modified in the Editor.
Summary It is not possible to correctly modify the Workbench/Runtime Host and Port parameters of a zenon Logic Project in the Editor. After the first modification, it is no longer possible to revert to the original settings. DescriptionIt is not ...
When using a driver in mode Simulation - programmed, in the zenon runtime an empty string of a variable of type string can`t be read when setting an empty string via the zenon logic workbench.
Summary An empty string can`t be read in the zenon runtime when using a driver in mode Simulation - programmed and setting an empty string via the zenon logic workbench. Therefore in the zenon runtime the string variable still shows the prior string ...
SNMP32 Driver no longer communicates correctly after compiling the Runtime files in zenon version 7.10 or higher to an earlier zenon version.
Summary In zenon version 7.10 or higher, compiling the Runtime files for zenon version 7.00 or lower causes a communication issue in the SNMP32 Driver. DescriptionIn zenon version 7.10 or higher, compiling the Runtime files for zenon version 7.00 or ...
Under specific circumstances the extended trend diagram window is displaced in the runtime.
Summary While zooming and scrolling in the extended trend screen, the diagram window might be translated to a wrong position and eventually move out of the screen in the runtime. DescriptionWhile zooming and scrolling in the extended trend screen, ...
When creating new straton projects or changing the communication parameters in the zenon logic runtime settings, this settings are not correctly applied to the Driver.
Summary When creating new straton projects or changing the communication parameters in the zenon logic runtime settings, this settings are not correctly applied to the driver. When opening the driver configurtion the settings are always overwritten ...
MATHDR32 Driver - It is not possible to insert more than 26 variables into the formula definition dialog.
Summary It is not possible to insert more than 26 variables into the formula definition dialog for the MATHDR32 Driver. It should however be possible to insert a maximum of 99 variables. DescriptionIt is not possible to insert more than 26 variables ...
When modifying a variable of the STRATONNG driver in zenon, the statusbits and timestamp of the corresponding variable in zenon logic will not be updated.
Summary The statusbits and timestamp of a variable of the STRATONNG driver will not be updated in zenon logic when setting a value to the corresponding variable in zenon. DescriptionThe statusbits and timestamp of a variable of the STRATONNG driver ...
Logix32 and LogixODVA driver: It is not possible to write values on large blockarrays (larger 500byte)
Summary It is not possible to write values on large blockarrays (larger 500byte) in both Logix32 and LogixODVA Driver. DescriptionIt is not possible to write values on large blockarrays (larger 500byte) in both Logix32 and LogixODVA Driver. ...
The names of the editor profiles may not change after importing an profile editor file in the Editor.
Summary When importing an editor profile file in the Editor the profiles names do not change as the profile names are not included in the export/import. DescriptionWhen importing an editor profile file in the Editor the profiles names do not change ...
Next page