7.10
Under specific circumstances the Production & Facility Scheduler screen filter does not work correctly in the runtime.
Summary It can occur that in the Production & Facility Scheduler screen the Time model group and Schedule criteria are not reflected in the Calendar although these are correctly filtered in the tree view. Description It can occur that in the ...
The runtime server closes unexpectedly after several manual redundancy switches under specific circumstances
Summary When in the runtime the function for redundancy switch is manually executed several times from a button that has the option "signature required" set, the server may close unexpectedly. Description When in the runtime the function for ...
Several functions are no longer available in the runtime for Windows CE 6.0 and higher
Summary Several functions and modules, like Recipegroup Manager, Historian Starter Edition and Extended Trend Starter Edition, are no longer available in the zenon Runtime for Windows CE, after an update to a newer build. DescriptionSeveral functions ...
Creating measurement documents via the SAP interface fails with the message 'INVALID_DATE'
Summary Storing variable values in SAP via the SAP interfaces 'measurement readings' feature does not work in some situations. When the runtime attempts to send the value to the SAP system it fails. An entry is created in the CEL, indicating that ...
Automatic keyboard not displayed for changing the description of a step in a Batch control matrix recipe
Summary When the automatic keyboard is used in a project, it will not be displayed when opening the dialog to change the description of a step inside a Batch control matrix recipe. Description When the automatic keyboard is used in a project, it will ...
Executing SAP function calls modifies the values of variables linked at import parameters when linear value adjustment is configured
Summary When a variable has linear value adjustment configured and it is linked at a SAP RFC function as IMPORT parameter, the value adjustment will be applied to the variable when executing the SAP fanction. Description When a variable has linear ...
System Information Collector does not collect error files from drivers
Summary When performing a scan with the System information Collector, error files of drivers are not stored in Scada > Versions > Version ???? > Errorfiles because these don't match the filter for files to be collected. Description When performing a ...
a project with missing mdf file is still displayed as OK in the System information Collector
Summary Even though a project's mdf file is missing (which means the database is invalid), SIC still displays the project with green background and a check mark, indicating that there is no problem. Further more it is not possible to detach the ...
opening a saved file in the System information Collector makes the application freeze under special circumstances
Summary When a saved SIC file contains an empty file (0kB) and one tries to open this SIC file in the System Information Collector, then the application will freeze wile loading the file. Description When a saved SIC file contains an empty file (0kB) ...
incorrect warning message for unattached dump files in System Information Collector
Summary When performing a full scan (dump files excluded), the dump files are displayed with the warning text "could not be attached". Actually, they are meant not to be attached, so there is no reason for the warning. Description When performing a ...
Values linked to variables are not always assigned in both directions when WPF in combination with DependencyProperties is used
Summary If a DependencyProperty is used to assign a value inside a WPF to another DependencyProperty that is linked to a variable in the SCADA, values are not written if one DependencyProperty is triggered. The value inside the WPF is changed ...
Process Gateway ICCP does not react on services DeleteNamedVariableList and GetNamedVariableListAttributes
Summary Despite ICCP Server during initialization informs that it supports mandatory services DeleteNamedVariableList and GetNamedVariableListAttributes it doesn't react on these requests from Client. Description Despite ICCP Server during ...
The number of alarm group / class / area is not included in the XML export file
Summary It is possible to manually configure the alarm group / class / area number ("Id") in the Editor, however this number is not included in the XML-file when exporting alarm groups / classes / areas Description It is possible to manually ...
Alarm areas: wrong value of status variables of linked Alarm Classes when number of alarms exceeds the size of ring buffer
Summary If the number of alarms exceeds the size of the ring buffer, the status variables of linked Classes in Alarm areas are calculated wrong. Description If the number of alarms exceeds the size of the ring buffer, the status variables of linked ...
In highly mashed grid the ALC calculation in zenon versions >=7.00 needs significantly more time as previously
Summary In some advanced project converted from older version to zenon versions >= 7.00, where the ALC grid is highly mashed, the ALC calculation takes significantly more time (~25s) as it was before. Description In some advanced project converted ...
Command Input - when you execute the "Lock" action in the Server-Standby environment the lock information appears twice in the list in the command screen.
Summary In zenon Network with Process Server and Standby Server after you execute in Command Input the action "Lock" the information appears in the list in the command screen twice. In zenon Network without Standby Server the issue doesn't occur. ...
An integration project of version 7.10 does not show historical alarms of 6.51 subproject (subproject uses different server than integration project)
Summary An integration project with subprojects where subprojects have different project servers, running with older zenon version - due to a step-by-step update to 7.10, the integration project server is on zenon 7.10 and the other servers are on ...
IEC61850 Server: wrong reaction on Abort service with user-data in OSI Session Layer.
Summary The IEC61850 Server supports Abort service - frame of type 25 on OSI Session protocol with 'user-data' including OSI Presentation and eventually OSI Association Control service. Since issue #174679 the Server is also able to react on ...
Under specific circumstances during redundancy switch-over a value received from the PLC on the standby server may be lost
Summary With a redundant runtime on server and standby server that are both under heavy load the server, the runtime on the standby server may fail to record a value from the PLC if this value is received from the PLC after the server has failed and ...
A zenon operator runtime as a client does not correctly switch over to the standby server after the server has failed.
Summary With a zenon supervisor runtime a a server and a zenon supervisor runtime as a standby server, a zenon operator runtime as a client does not switch over to the standby server when the server has failed or was shut down. Description With a ...
Restoring a project backup in the editor may fail under specific circumstances.
Summary If it is used certain Cyrillic characters in a driver identification, the respective driver configuration file name in the project backup is corrupted, containing invalid characters, preventing the project backup to be restored later in the ...
Under specific circumstances the remote project reload and the remote close runtime functions do not work as expected.
Summary In certain Windows CE platforms the editor remote transport functions "Remote: Reload project" and the "Remote: Close Runtime" are only executed in the runtime after the "Remote: Close Runtime" button has been clicked in advance. Description ...
SNMP32 driver stops when browsing an agent with the option to use snmpv2c poling active
Summary When the option to use snmpv2c polling is active, browsing an agent causes the driver to stop under specific circumstances. When snmpv2c polling is acitve it is not possible to browse all OIDs from an agent. Description When the option to use ...
SNMP32 driver closes immediately after clicking "browse" when importing variables from the driver using the name / identification for addressing
Summary When importing variables from the SNMP32 driver in the editor and selecting "browse" in the dialog, the browse dialog closes immediately, the driver does not browse and no variables can be imported. Description When importing variables from ...
Modbus Energy Driver should support 64 Bit Long Int Datatypes
Summary Modbus Energy Driver should support 64 Bit Long Int Datatypes Description Modbus Energy Driver should support 64 Bit Long Int Datatypes Solution Added LINT & ULINT data type. Issue Number: 31904 Fixed on Date: 8.5.2014 Versions: 7.11 0 BUILD ...
The webclient does not start on Internet Explorer 11.
Summary The webclient cannot start in the Internet Explorer 11 since Microsoft changed the browser user agent string. Description The webclient cannot start in the Internet Explorer 11 since Microsoft changed the browser user agent string. Solution ...
Under specific circumstances the runtime may close unexpectedly when a screen is closed.
Summary The runtime closes unexpectedly if a screen containing an element of a symbol being refreshed is closed. Description The runtime closes unexpectedly if a screen containing an element of a symbol being refreshed is closed. Solution An issue ...
Under specific circumstances the editor closes unexpectedly when editing the properties of a combined element.
Summary It may occur that the editor closes suddenly when selecting the Automatic Line Coloring function type of a combined element containing symbols. Description It may occur that the editor closes suddenly when selecting the Automatic Line ...
The runtime may show an exception warning message after creating a scheduler.
Summary After creating a scheduler in the runtime and re-opening the Production & Facility Scheduler screen it may be displayed instantly or later an exception message. Description After creating a scheduler in the runtime and re-opening the ...
The Web Server should be also available in 64 Bit version.
Summary The Web Server is only available in 32 Bit but should also be delivered a 64 Bit version. Description The Web Server is only available in 32 Bit but should also be delivered a 64 Bit version. Solution The zenWebSrv.exe has been ported to 64 ...
Server is not responding to user actions if SMS gateway method is used in a redundant system
Summary If a redundant system is used in combination with Message Controls SMS gateway dispatching method, after some time the runtime on the server is no longer responding. Description If a redundant system is used in combination with Message ...
Under specific circumstances the XML import of reaction matrices is aborted in the editor.
Summary If it is tried to XML import a reaction matrix with the same name and type of an existent in the project the import gets aborted. Description If it is tried to XML import a reaction matrix with the same name and type of an existent in the ...
A specific ARM processor is not correctly recognized by the remote transport / Update Windows CE runtime wizard in the editor.
Summary The ARM1176JZF-S-S3C6410 from Samsung Electronics is not correctly recognized by the remote transport and Update Windows CE runtime wizard in the editor. Description The ARM1176JZF-S-S3C6410 from Samsung Electronics is not correctly ...
Under specific circumstances the Import S7 project wizard does not detect correctly the current CPU in use of a S7 project.
Summary When importing variables to the editor from a S7 project where it was changed occasionally the used CPU, the Import S7 project wizard displays the original CPU not allowing completing successfully the wizard. Description When importing ...
It may occur that when copying or XML importing a screen switch function in the editor some of its properties are not transferred.
Summary When copying or XML importing in the editor a screen switch function of a Production & Facility Scheduler screen type the width value of the columns is lost. Description When copying or XML importing in the editor a screen switch function of ...
Under specific circumstances the runtime may close unexpectedly when writting values to the hardware via the variable diagnosis screen.
Summary When executing the diagnosis screen specific function all variables: write set values from the standby server with both servers running, the runtime may close suddenly if this function is executed repeatedly with different variable's ...
It may occur that the webclient setup does not register the necessary services to run the webclient.
Summary On Windows 7 64 Bits the webclient setup may fail to register the zenAdminSrv and zenLogSrv services causing the webclient ActiveX control to fail to start in the internet browser. Description On Windows 7 64 Bits the webclient setup may fail ...
Under specific circumstances the close frame function is not executed in the runtime.
Summary The close frame function may not be executed if 7.11 runtime if the runtime files were created for a previous runtime version. This issue also affects the webclient runtime when a project of an earlier version is executed in the 7.11 ...
It may occur that the Active Directory-Lightweight Directory Services (AD-LDS) configurations performed in the editor are not considered in the 7.11 runtime.
Summary If it is used the AD-LDS for the user administration, the 7.11 runtime does not use the AD-LDS user and password entered in the editor. Description If it is used the AD-LDS for the user administration, the 7.11 runtime does not use the AD-LDS ...
Copy and paste of values in the value column of the recipe table for recipe values is not always accepted after saving
Summary Under circmstances the changes to recipe values made in the recipe table of the Recipe Group Manager screen in the runtime, using either the default list or a format file of the report generator are not accepted when saving the recipe if the ...