7.00
When deleting an element from a screen, editor quits unexpectedly when using the OnElementDeleted event handler
Summary When the OnElementDeleted event handler is used in the editor, it closes unexpectedly when an element is deleted from a screen. Description When the OnElementDeleted event handler is used in the editor, it closes unexpectedly when an element ...
ArchiveVariables.Item(0) contains the trigger variable of an archive instead of the first archive variable
Summary In version 6.51 SP0 Build 8 and before, the definition for ArchiveVariables.Item(0) was that this element should contain the first variable of the archive. From there on, it contains the trigger variable. This also applies to version 7.00 ...
When using Windows XP, the editor closes unexpectedly when creating a Send Message function
Summary When using Windows XP, the editor closes unexpectedly when creating a Send Message function Description When using Windows XP, the editor closes unexpectedly when creating a Send Message function Solution An issue was addressed in the ...
If the Cross Reference List Light window was displayed in the main window and the default profile is restored later, the editor closes unexpectedly
Summary If the Cross Reference List Light window was displayed in the main window and the default profile is restored after a restart of the editor, the editor closes itself with prompting for building runtime files. On the next start, the editor ...
Importing a data type via XML to merge it with an existing one results in limits being lost
Summary Importing a data type via XML to merge it with an existing one results in limits being lost. This effect can be only seen when restarting the editor – as long as the editor is open, the limits are kept in memory (no matter if project is ...
Text-To-Speech sending method ignores the "Time Between Attempts" setting
Summary Message Control messages that use Text-To-Speech as sending method are not using the "Time between attempts" setting from the Message Control node in the editor. This can cause messages after the first one not to be transmitted because ...
Runtime closes during start-up if unsent messages are in the queue
Summary If the runtime is closed with messages still not sent, the message queue is saved onto the hard disk drive. If the runtime now is restarted, it exits unexpectedly. Description If the runtime is closed with messages still not sent, the message ...
If automatic daylight saving time adjustment is turned off in Windows CE, time stamps are displayed incorrectly in the runtime
Summary If automatic daylight saving time adjustment is turned off in Windows CE, time stamps are displayed incorrectly in the runtime. Time stamps will be displayed with current hour plus the according adjustment for the timezone, but no DST time. ...
Remote Transport from version 7.00 is not working correctly if target is a CE version smaller 7.00
Summary Remote Transport from version 7.00 is not working correctly if target is a CE version smaller 7.00. The editor displays the license dialog, no matter if a license has been entered or not. After the license dialog, an error message is ...
Color palette description is not displayed correctly under Windows XP
Summary In the editor, the color palette description is not displayed correctly – e.g. too big font, text 45° rotated. DescriptionIn the editor, the color palette description is not displayed correctly – e.g. too big font, text 45° rotated. Solution ...
If a context menu is copied and pasted in the editor, behaviour on an element in the runtime is not like projected for the copy
Summary If a context menu is copied and pasted in the editor and then used on a different element, behaviour is not like expected. In the runtime, it seems like the copied element has no action at all. After the original context menu was called for ...
When a report is viewed in the runtime, there is no auto-refresh of the report after a unit switch
Summary When viewing a report in the runtime, there is no auto-refresh of the report after a unit switch occurs in the runtime. A manual refresh displays the correct values and the correct unit. When the language is switched (just for comparison), ...
The screen switch function to the Report Viewer screen does not allow "direct selection" of a .rdl file on a fixed location
Summary When projected in the editor, the screen switch function should enable the user to select from a *.rdl file that has been created in the editor before. However, when a screen switch is performed, no selection is allowed. Description When ...
System Information Collection tool closes unexpectedly during information collection
Summary System Information Collection tool closes unexpectedly during information collection. It seems to happen when it tries to collect the event log data of the operating system (but not necessarily). Description System Information Collection tool ...
Editor exits unexpectedly when two reports are opened in combination with a multi-user project environment
Summary In a multi-user environment, a client creates a report in the Report Generator. If another client creates a report and opens the report of the first client, the editor closes unexpectedly when trying to synchronize the multi-user project. ...
Sending queue for SAP function calls is not processed completely when triggered very fast
Summary In some cases, the sending queue for SAP functions is not processed completely when triggered very fast. Description In some cases, the sending queue for SAP functions is not processed completely when triggered very fast. Solution An issue ...
Memory usage of runtime increases during time when using the Extended Trend Module in combination with profiles
Summary When a profile is added for an Extended Trend screen which is repeatedly selected after reopening the Extended Trend screen, memory usage increases without being freed at any time. Description When a profile is added for an Extended Trend ...
Sending a message over SMTP is not working properly in combination with SSL/TLS
Summary Sending a message over SMTP is not working properly in combination with SSL/TLS. No message is created and in the Diagnosis Viewer, the following entry appears: "Creating SSL/TLS Method failed. Errorcode: 336236705" DescriptionSending a ...
Trying to print or export a report from Report Viewer is not working properly in certain circumstances
Summary When opening a report designed in the Report Viewer, everything is working as expected. When trying to print or export it, a message is shown that an exception occurred: "An error occurred during local report processing" . DescriptionWhen ...
When the runtime is started in fullscreen mode, the Windows taskbar is still visible
Summary If the Windows taskbar is not set to auto-hide and the runtime is being started in fullscreen mode (set in "Project" – "Graphical design" – "Runtime title" ), the taskbar is still visible. DescriptionIf the Windows taskbar is not set to ...
IEC61850 Server should limit max number of dynamic Data Sets according entries in SCL file
Summary In the zenon Logic driver IEC61850 Server configuration there are settings for dynamic Data Sets. These settings are absolutely excessive as the Standard (850-6) defines them already in SCL-file. Description In the zenon Logic driver IEC61850 ...
IEC61850 Server cannot use in GOOSE Subscriber the data type ARRAY
Summary In IEC61850 Server configuration, in GOOSE subscription configuration, the Data Attributes of ARRAY type - when picked up - are created as single variables, not arrays. GOOSE with such configuration does not start. Description In IEC61850 ...
The interlocking "Area with undefined status would increase" in some Topology does not work correctly with new ALC algorithm "Input takes priority"
Summary The topological interlocking "Area with undefined status would increase" in some Topology networks does not work correctly with new ALC algorithm "Input takes priority". Description The topological interlocking "Area with undefined status ...
Command window deactivates button for alternative value of the direction the response variable already has
Summary In the command window the button for alternative value is active only for one direction. Using command window it is not possible to set variable in alternative value same as current process value. It is possible only using context menu - ...
The context menu for command with ID_CMD_AUTO gets automatically text "Command" and then does not unwrap menu entries in the Runtime
Summary When you create a new context menu and choose as action type 'Command' then the property Text gets automatically value "Command". Even when next the property Menu ID is set to ID_CMD_AUTO then in the Runtime menu entries will not be created ...
Command window field "active action/command" should be reset after Cancel
Summary In command window the name of current action can be displayed in the field "active action/command". When you press the button "Cancel" the text in this field stays. The command window should reset the field "active action/command" when action ...
Under specific circumstances two phase instances may become active after RT restart
Summary In a batch control recipe if two phase instances of the same phase exist in a parallel, normally without an explicit force, only one phase is active at the same time. The other phase is waiting for the first phase to finish. However after a ...
runtime closes unexpectedly on starting a specific batch control recipe under specific circumstances
Summary When starting a batch control recipe in manual mode, while advanced logging in the diagnosis server is active, where the batch control recipe contains more than 8 instances of an operation, the runtime closes with an unhandled exception. ...
stratonNG driver cannot read string variables
Summary In the version 1800 of the stratonNG driver string variables cannot be read anymore. An Element from type dynamic text stays empty. In diagnosis viewer (deep debug) you can see that the driver gets the value from zenon Logic runtime, but then ...
zenonLogic Profinet IO driver (master) does not start when reconnecting special device
Summary With some profinet devices (in this case phoenix Contact Interbus / Profibus Gateway) there is a problem with the reconnect of the profinet driver. The Gateway sends a mismatch of modules to point on existing diagnosis messages. But it ...
The "lengthen curve" functionality in extended trend does not work for archive data
Summary When the property "lengthen curve" is activated for an archive data curve (on change) it does not work. The curve is not lengthened at all. If also the property "area display" is active the area is lengthened, but still the line is not. ...
Webclient and server hangs if Reports are executed
Summary When executing Reports (Module: Report Generator) in a project leads in network projects to the issues: - Server hangs if you open several pics - Webclient crashes if you open several pics Description When executing Reports (Module: Report ...
Runtime on client hangs/stops working if time filter / diagram settings in Extended Trend screen are changed
Summary If you change the time filter in an ETM screen diagram on the client, the client project stops working. Description If you change the time filter in an ETM screen diagram on the client, the client project stops working. Solution The curve ...
With the DNP3_NG driver, not all significant digits of a double float analog input are mapped to the LREAL variable in the runtime
Summary When a DNP analog input object, group 30 variation 6 or group 32 variation 6 or variation 8 is received by the DNP3_NG driver, it is correctly considered a double precision float. The value received in the runtime however did not contain all ...
The DNP3_NG driver sporadically closes with an unhandled exception on a specific system when browsing variables online in the editor
Summary When browsing variables from the outstation (class 0 poll) using the DNP3_NG driver in the editor, the driver sporadically closes with an unhandled exception, after the dialog was displayed with the variables to be imported. Description When ...
The DNP3_NG driver only sends read requests for event class data to the outstation when IIN1.1, IIN1.2 or IIN1.3 remains TRUE in the telegram header of outstation responses.
Summary An outstation can indicate with the internal indication IIN1.1, IIN1.2 or IIN1.3 that class data is available for event class 1, event class 2 or event class 3 respectively. According to the standard a DNP3 master shall immediately send a ...
Variable of the DNP3_NG driver not marked INVALID when reading a point explicitly, with an invalid point number
Summary Variables that are read explicitly, (not returned in a class poll) with a DNP point number configured at the offset which does not exist in the outstation, are not marked INVALID in the runtime. Description Variables that are read explicitly, ...
No connection timeout when browsing variables online in the editor with the DNP3_NG driver
Summary When browsing variables from the editor using the DNP3_NG driver, there is no connection timeout when the outstation is not available. Description When browsing variables from the editor using the DNP3_NG driver, there is no connection ...
The DNP3_NG driver does not start on certain systems with only certain versions of the Microsoft Visual C++ 2008 runtime installed
Summary The DNP3_NG driver does not start (driver configuration cannot be opened) on systems where only certain versions of the Visual C++ 2008 runtime are installed. The event log shows an issue with the side-by-side installation of the DNP3_NG.exe ...
DNP332 driver and DNP3_NG driver closes unexpectedly on receiving an object with a 0 timestamp on systems with a timezone greater or equal than GMT+1
Summary When the DNP332 driver or the DNP3_NG driver receives a DNP object that contains a 0 timestamp, (01.01.1970 0:00:00.000) the driver can close unexpectedly processing this timestamp value when the system is configured to use a timezone larger ...