14
Trend screen diagarm Cancel button issue in zenon Service Engine
Description Clicking the Close button in the ETM screen set back the changes to the initial settings instead of closing the dialog. The issue has been fixed and the behavior is now as expected. To benefit from this fix: Update your zenon Software ...
Exception when compiling + Symbol unknown
Description Under operating system configured to use as current language the none-Unicode: Chinese (Simplified, China) issue while compiling the program. The compiler reports compilation errors. The issue has been addressed and the behavior is now as ...
straton OPCUA Client does not recover connection after stop/restart of the OPCUA Server
Description The OPC UA Client did not restore the connection after a stopping and restarting of the OPC UA Server. The issue has been addressed and the behavior is now as expected. To benefit from this fix: Update your zenon Software Platform to the ...
Python - Library import doesn't work with CP5 Python wrapper
Description Importing the Python library with C5P Phyton wrapper led to issues. The issue has been addressed and the behavior is now as expected. To benefit from this fix: Update your zenon Software Platform to the latest build of zenon 14or higher. ...
When using "Insert FB" within the vertical bar in a ST program to insert a function block, this does not lead to any action (function block will not be added to ST program)
Description The function block creation in ST program via “Insert FB” in the vertical toolbar was not successful. The issue has been addressed and the behavior is now as expected. To benefit from this fix: Update your zenon Software Platform to the ...
Soft Scope - Status Bits info displayed are not correct
Description The displayed Status Bit Information in the Soft Scope was not correct. The issue has been addressed and the behavior is now as expected. To benefit from this fix: Update your zenon Software Platform to the latest build of zenon 14or ...
FBD -> ST Conversion: bad reconstruction of "UNTIL" statement
Description The “UNTIL” condition was not correctly reconstructed in case of a FBD -> ST language conversion. The issue has been addressed and the behavior is now as expected. To benefit from this fix: Update your zenon Software Platform to the ...
SSO-token from IDS is not re-used in HTML-Screen
Description Previously, different WebView2-based components used separate folders to store their data. This resulted in multiple logins, for example, because sessions were not shared across all components. The issue has been addressed and now only ...
x5BusIec850s: do not publish GOOSe with the simulation bit
Description The IEC61850 server published GOOSE messages if the test bit was set and LPHD1.Sim.stVal has been set to TRUE. The issue has been addressed and GOOSE messages are no longer published with simulation set, when LPHD*.Sim.stVal is set to ...
ReportEngine GraphQLInterface parameter "LanguageFilter" is missing
Description The Report Engine GraphQLInterface parameter "LanguageFilter" was deleted in one of the cleaning stories from the ReadVariables. The parameter is now available again. To benefit from this fix: Update your zenon Software Platform to the ...
Wrong direction of Bargraf after Project conversion (V10->V14)
Description After a zenon project conversion (version 10 to version 14) the bar graph displayed incorrect content. The issue has been addressed and the bar graph works properly now. To benefit from this fix: Update your zenon Software Platform to the ...
Web Visualisation Extended trend when curve not visible y axis is still visible
Description If a curve has been added and removed via the curve visibility variable in the WVS Trend, the axis stayed visible. In addition, the scales were not correct. The issue has been fixed and the behavior is now as expected. To benefit from ...
IEC61850 Server - Subscribing to GOOSE messages in simulation fails if LPHD instance is not 1 (LPHD1)
Description Subscribing to GOOSE messages in simulation always failed, if LPHD instance was not 1 (LPHD1). The issue has been fixed and subscribing to GOOSE messages in simulation works, if at least one LPDHx.Sim.stVal instances is TRUE. To benefit ...
Reimporting a batch unit with a control strategy doesn't work properly
Description In case of a re-import from a batch unit with a control strategy issues with the TAG handling occurred. The issue has been addressed and the re-import works properly now as expected. To benefit from this fix: Update your zenon Software ...
In WVS Screen Move center function doesn’t behave as Service Engine (Desktop)
Description The "Screen: Move center" function opened a Wordview Screen and moved to the indicated station position in the Service Engine, but not in the WVS. The issue has been addressed and the WVS behavior is now the same as in the Service Engine. ...
No tooltip is shown in ST programming window for outputs of subprograms
Description Tooltip was not available in the ST programming window for the output of subprograms. The issue has been fixed and tooltip is now also available for subprograms. To benefit from this fix: Update your zenon Software Platform to the latest ...
Output window: incorrect warning in the output window for screen switching fuction in the RGM screentyp
Description Previously, a warning was displayed in the output windows during checks if no recipe had been defined in the screen switching function. The behavior has been changed so that a warning is no longer displayed. To benefit from this fix: ...
OPC UA client stops when server uses tags with unknown types
Description The OPC UA client stopped when the server used TAGs with unknown types. The issue has been addressed and the OPC UA client now keeps operating when the server used TAGs with unknown types. To benefit from this fix: Update your zenon ...
C FB instance as member of UNION should be an error when compiling
Description If a C function block instance is member of a UNION it did not result in an error message when build Startup Project. The issue has been fixed and the mentioned build Startup Project procedure results in an error now. To benefit from this ...
Use the DELETE_W function will leads to a segmentation fault
Description The usage of the DELETE_W function led to a segmentation fault. The issue has been fixed and the behavior is now as expected. To benefit from this fix: Update your zenon Software Platform to the latest build of zenon 14 or higher. Item ...
texte - texte file don't display correctly with utf8 encryption
Description In zenon Logic, a text file with UTF-8 encoding is not displayed correctly. After inserting the file via “Insert external item”, its text content is displayed incorrectly. This error has been fixed. UTF-8 text files are inserted and ...
eSignature does not work if user authentication via Active Directory and the ‘Change password on first login’ option is active in zenon Engineering Studio
Description eSignature did not work if user authentication via Active Directory and the “Change password on first login” option was enabled in the Engineering Studio. The issue has been fixed and the behavior is now as expected. To benefit from this ...
Dump Occurrence When Starting SE in Process Recorder Mode After Reboot the PC
Description Dump problems occurred when the Service Engine was started in process recorder mode after restarting the PC. The problem has been fixed and the Service Engine now starts or stops correctly when playback is started or stopped while the ...
Hidden input in WVS write set value dialog ignored
Description The “Hidden input” property of the dynamic text was ignored in the WVS if the "Write set value via" property was set to "Standard dialog". The issue has been fixed and the behavior is now as expected. To benefit from this fix: Update your ...
Password change at first user logon works via operating system but not via zenon SE ; no AD login possible
Description In the Edge Gateway frontend, the user password can no longer be changed in MS Active Directory, when the zenon system is not a member of the domain. Despite correctly entering the previous password and the new password including password ...
AccessOPCua PG crashes on customer when when connected to an OPC UA Client
Description The OPC UA Server Process Gateway crashed if it was connected to an OPC UA Client. The issue has been fixed and the behavior is now as expected. To benefit from this fix: Update your zenon Software Platform to the latest build of zenon 10 ...
OPCUA Server crash with higher (10 new per second) load of alarms
Description The OPCUA server crashed when a higher load alarms occurred. The issue has been fixed and the behavior is now as expected. To benefit from this fix: Update your zenon Software Platform to the latest build of zenon 14 or higher. Item ID: ...
[Edge Gateway] Missing OPC UA Client driver connection property prevents creation of the connection
Description Due to a problem with the OPCUA32 connection property (Extension Objects) the creation of the connection failed. The issue has been fixed and the behavior is now as expected. To benefit from this fix: Update your zenon Software Platform ...
[BUG] comment with Umlaut entered in UAExpert is not taken over correctly in the service engine
Description Service Engine does not receive comments with umlauts correctly from UaExpert. The issue has been fixed and the behavior is now as expected. To benefit from this fix: Update your zenon Software Platform to the latest build of zenon 14 or ...
[Edge Gateway] GET drivers API gets called many more times than necessary
Description The GET drivers API has been called unnecessarily often. The issue has been fixed and the behavior is now as expected. To benefit from this fix: Update your zenon Software Platform to the latest build of zenon 14 or higher. Item ID: ...
[Edge Gateway] Columns settings are empty at first open of EGW Frontend
Description When the Edge Gateway Frontend was opened for the first time, the columns were empty. The issue has been fixed and the behavior is now as expected. To benefit from this fix: Update your zenon Software Platform to the latest build of zenon ...
STLTimeZoneInformation returns bias with wrong sign
Description Time zone information is implemented differently on Windows and Linux based systems. Different standard bias values were returned for CET (standard bias of 3600 and a daylight bias of 7200 (current year)/standard bias of -3600 and a ...
Mend: vulnerability in curl-curl-8_2_0 / NativeLibraries - master / Direct Dependency
Description Mend reported a vulnerability in curl-curl-8_2_0 with a CVSS v3 score of 9.8. The issue has been fixed via a build version update. To benefit from this fix: Update your zenon Software Platform to the latest build of zenon 14 or higher. ...
S7TCP driver is adding the timezone difference to a value of a DATE_AND_TIME Variable
Description The S7 TCP-IP driver did not handle timezone differences regarding UTC and local system time correctly for DATE_AND_TIME variable values. The issue has been fixed and the behavior is now as expected. To benefit from this fix: Update your ...
3S_V3: when using exception handling or also when using simple WSTRING variables, the values of those variables are containing incorrect characters
Description The variable values of WSTRING variables of the 3S_V3 driver contained incorrect characters. This issue has been addressed by improving the handling of WSTRING variables. To benefit from this fix: Update your zenon Software Platform to ...
zenon logic runtime crash with C-compiled logic code
Description After compiling the project in the Engineering Studio and starting the Service Engine the Logic Service crashed when it is started. The issue has been fixed and the behavior is now as expected. To benefit from this fix: Update your zenon ...
3S_V3: In specific scenario when starting the service engine the driver instance either crashes or blocks the service engine from starting
Description Under certain circumstances the 3S_V3 driver crashed or blocked the Service Engine. This issue has been addressed by improving the exception handling mechanism of the driver. To benefit from this fix: Update your zenon Software Platform ...
STRATONNG driver sends out write command with wrong value 0 for pokes received immediately after startup
Description If STRATONNG variables have been used in the class linking and the Service Engine is closed, these counters are reset to 0 at next start. This led to incorrect information in the Service Engine. The issue has been fixed and the behavior ...
broken network backward compatibility for editing of archives
Description The network backward compatibility for editing archives has been broken. The issue has been fixed and the behavior is now as expected. All computers prior to the specified versions must also be updated. This also applies to systems that ...
TIA Driver crashes after starting communication to the PLC with a specific project
Description The TIA driver crashed, if an import has been done from a PLC project (or the project has been started in the Runtime or the Service Engine) in a build that used AGLink in version 6.0.2.0. To fix this issue the AGLink version has been ...