Batch Control: Service Engine crashes when a "%" character is used in the name for Matrix or PFC recipe
Description In Batch Control, the character "%" is prohibited for recipe names. However, the input was not prevented. If the recipe name contained the character "%", the Service Engine crashed when the recipe was saved. This behavior has been ...
Linking variables Limit min/max values in an operation are set to 0 after releasing the Master recipe.
Description In Batch Control, when a Master Recipe is released, the values of the variables linked in an operation for minimum and maximum values are set to 0. However, when the operation is released, the values of the linked variables are retained ...
SYSDRV "[Project summary] Input set value: Current default set value" variable inconsistent values over Logic Service to Service Engine connection fieldbus
Description In zenon the system driver variable "[Project summary] Input set value: Current default set value" does not correctly transmit values that are shared with zenon Logic via shared memory. If values are changed, the previous values are still ...
CAN - incorrect scaling after export to DBC file
Description In zenon Logic, data is not exported exactly during DBC export from CAN bus. Differences are visible for factor and offset. This has been fixed. Factor and offset are exported correctly to DBC again. To benefit from this fix: Update your ...
SNMP Driver crashes when the project is closed
Summary zenon driver crashes on closing the Service Engine via exit button. This has been fixed. Description If the Service Engine is closed via the "Exit" system button, a driver may crash while the active connection is closed. This does not always ...
save after interlock assignment(change) in symbol visibility setting causes zenon editor crash
Description If a symbol whose visibility has been assigned an interlocking is saved while the Interlocking is still selected, may the Engineering Studio cause to crash. This error has been fixed. To benefit from this fix: Update your zenon Software ...
OPCUA Client Driver: Extension Objects "Switching Time" in "Schedule" do not work properly
Description In the OPCUA client driver, setting a value other than 0 for "Switching Time" in "Schedule" leads to an error. All variables become invalid. These variables can be set to 0 again with another OPCUA client. They are then spontaneous again. ...
Loaded, modified, and stored archive capsules are corrupt
Description In Historian, completed archive capsules are corrupted under Linux if they are completely re-saved. They have an incorrect file size or the archive files are not compatible with the Service Engine under Windows OS. This means that the ...
in the version 12 the connection with the S5TCP driver does not work
Description As of zenon version 12, the S5TCP driver cannot establish a connection to the PLC. The problem does not occur in versions prior to zenon 12. Connections that work in version 11 or earlier can no longer establish a connection after ...
[MSI Interface] Deleting an Alarm Event Group prevents sending of Exception Messages
Summary In the Werum MSI Interface, deleting an alarm/event group leads to an error under certain conditions. This has been fixed. Description In the MSI configuration an alarm/event group is used to define an exception message. Later, a group is ...
XMD: Bad reading of GSDML with specific comment tag
Description In zenon Logic the Profinet IO controller does not read the GSDML file correctly. A specific comment tag leads to the error message "<TEXTID NOT FOUND>". This error has been fixed. The GSDML file is read correctly again. To benefit from ...
Denial of Service vulnerability in WVS Ops-Manager
Description The WVS OPS Manager contains libraries from other software manufacturers. In one of these applications - YARP - a vulnerability was discovered that allows Denial of Service attacks. This vulnerability has been fixed. The version of YARP ...
MODBUS: should give an option to always display offsets instead of addresses for variables in the tree
Description In zenon Logic the MODBUS configuration displays absolute addresses instead of indices for a variable. This is due to a program change in zenon Logic. This problem has been fixed. A new option "Show offsets in the tree" has been ...
'XML export all' for allocations only exports the first allocation
Description For allocations, only the first allocation is exported with the "XML export all" command. This error has been fixed. With the "XML exportall" command, all existing allocations are now exported again as expected. To benefit from this fix: ...
WVS: memory leak on more than 1000 variable entries in AML/CEL
Description In the Web Visualization Service (WVS), a memory leak can occur when using more than 1000 variable entries in AML or CEL. In this case, the performance diagram shows that the load from private bytes increases steadily. The Service Engine ...
Lot filter - last lot returns first lot with cyclic archives
Description The lot filter shows the first lot when "Last lots" is set. This happened due to incorrect sorting of the lots. This error has been fixed. The lots are now sorted again from the most recent to the oldest. So the last lot is used again for ...
zenon Logic: Ethernet/IP Adapter and Ethernet/IP Scanner will not be started in Logic Service
Description In zenon Logic ServiceEthernet/IP Adapter and Ethernet/IP Scanner are not started, although they were configured correctly in Logic Studio. When starting the Logic Service they are not started as expected. Diagnosis Viewer logs indicate ...
IIoT Services API delivers the wrong report parameter data type, equipment tree nesting or time filter granularity when the report parameter name contains an underscore
Description In the Report Engine, a parameter name with an underscore is used in a report. If this report is deployed with the "Available in IIoT Services" option active, the IIoT Services API returns the wrong report parameter data type, the wrong ...
[MSI Interface] Sending an Exception Message freezes the Service Engine
Description If an exception message is triggered in the Werum MSI Interface for which an identifier is defined, the Service Engine can freeze. Identifiers enable the correct assignment of the exception message to the linked property. This error has ...
Variable identification in the Variable Diagnosis screen cannot be translated in Subproject from Integration project
Summary In the Service Engine, not all variables are translated as configured in the Variable Diagnosis screen. This has been fixed. Description In the Service Engine, with Multi Project Administration, the identification for variables from the ...
Crash when converting LD to FFLD
Description In zenon Logic a crash occurs when converting a program from Ladder Diagram (LD) to Free Form LadderDiagram (FFLD). This error has been fixed. The conversion from LD to FFLD occurs without errors as expected. To benefit from this fix: ...
Editor crashes when mutltiple files are deleted with "Yes all"
Summary The Engineering Studio crashes when deleting multiple files. This has been fixed Description If several files are selected for deletion in the EngineeringStudio and the deletion is confirmed via the "Yes all" button, the Engineering Studio ...
CEL category: CEL entries XML import of linked categories is not in correct order
Summary In the zenon Categorization exported entries are not always imported correctly. This has been fixed. Description In zenon Categorization, CEL entries that are manually linked to categories are saved in the order in which they were added. ...
Submenus in main and context menus do not work correctly (zenon 12)
Description In zenon version 12 submenus for main menus and context menus do not work correctly. It is not possible in Engineering Studio to create a second submenu in the second level. In the Service Engine, the function associated with a submenu is ...
ETM: Performance issues when displaying aggregation archive data
Description In the Extended Trend, displaying aggregated archives with refresh rate 1 needs more CPU resources than displaying the corresponding base archive with refresh rate 1 over the same time range. This behavior has been improved. The display ...
Communication Reset after one hour for the TIA driver with firmware 3.0
Description If the TIA driver is operated with firmware 3.x, the PLC performs a reset in the Service Engine after one hour of operation. Communication is interrupted and restarted. This reset always occurs again after one hour. This behavior has been ...
Language setting not considered on Smart Client V12 for standard dialogs
Description In the Smart Client, the selected language setting is not correctly applied to standard filter dialogs. These dialogs are always displayed in German, regardless of the language configured in the Startup Tool or in zenon6.ini. This error ...
Zenon logic crash - Astrazenca Project
Summary Unexpected Logic Service crash when using shared memory. This has been fixed. Description If data types are incorrectly advised during the exchange between Service Engine and Logic Service via shared memory - for example Numeric variables on ...
Broken GFX list configurations
Description In Batch Control, the width of configurable lists is not calculated correctly in the Service Engine. When configured as pixels, the defined pixels are interpreted as characters. For example, a column width of 100 pixels is displayed as ...
Engineering Studio Warning: "function '' contains invalid parameters and might not work correctly" is wrongly displayed
Description If a screen switching function to an Extended Trend screen exists in a Smart Object Template, a warning is always displayed when it is instantiated. This warning states that the function contains invalid parameters and may not work ...
Blue Screen of Death when registering lots of multicast addresses using the CDProtDrv
Description If a lot of multicast addresses are registered simultaneously via the COPA-DATA Multiple Network Protocol driver (CDProtDrv), the operating system crashes with a stop error. This error has been fixed. Registering many multicast addresses ...
ES: Linked macros and wizards settings get lost if you open settings dialog again
Summary In the Engineering Studio, links to macros and wizards are dropped when the "Linked Macros and Wizards" dialog is opened. This has been fixed. Description In the EngineeringStudio, up to 5 icons of the "Macros andWizards" toolbar can be ...
The SE reports an unhandled exception when closed while an evacuation to the Data Store is running
Summary The Service Engine reports an unhandled exception while evacuating data to Data Storage. This has been fixed. Description The Service Engine reports an unhandled exception if data is being evacuated to Data Storage while the Service Gateway ...
LSIS Driver doesn't fit the read/write address If variable create the bool type.
Description The LS Industrial Systems XGT driver (LS_XGT) does not use the correct read/write address for variables of type Bool. The driver writes to a different address than it uses for reading. This behavior depends on the configured type. This ...
CD_SVA_2023_3: CodeMeter Runtime Security Vulnerability: CodeMeter Library used for the Service Engine on Linux should be updated for version 12 and version 14
Summary Security vulnerability in CodeMeter Runtime fixed. Description The CodeMeter Runtime necessary for zenon license management contains in version 7.60b a security vulnerability for the Service Engine under Linux. For zenon versions 12 and 14 ...
SO variable mapping rule should be applied when pressing 'Apply' not only when exiting the dialog w/ OK
Description When an Smart Object variable mapping rule is applied to an existing Smart Object instance via the API, the variable mapping is not saved. It is only saved if you manually open the variable mapping dialog and click “OK”. This has been ...
Unhandled exception: SE screen Shift Management: creating new shift and switch from tab General to Breaks
Description An unhandled exception occurs in the Service Engine on the Shift Management screen. The error occurs when creating a new shift, switching from the “General” tab to the “Breaks” tab in the dialog. This error has been fixed. To benefit from ...
STRATONRT: log CPU utilization warnings and errors only when the value has exceeded the previous maximum
Description The zenon Logic Service permanently logs CPU usage warnings and errors every 5 seconds, even if the value does not modify. This behavior has been corrected. CPU utilization messages are now only logged when a new value occurs. Lost PLC ...
Exiting the RGM screen leads to a "Save changes" dialogue which is unwanted in some cases
Summary The "Save changes" dialog newly introduced with zenon 12 when exiting an RGM screen could not be suppressed. This has now been adjusted. Description With zenon 12, a modal "Save changes" dialog was introduced when exiting the RGM screen, ...
Category Collection not available in Service Engine ProjectServiceExtension
Description CategoryCollection property is not available in the Service Engine via the API, even though it is documented to be available (Read-only). This behavior has been changed. Read-only access to category mapping is now available via API in the ...