When creating new straton projects or changing the communication parameters in the zenon logic runtime settings, this settings are not correctly applied to the Driver.

When creating new straton projects or changing the communication parameters in the zenon logic runtime settings, this settings are not correctly applied to the Driver.

Summary

When creating new straton projects or changing the communication parameters in the zenon logic runtime settings, this settings are not correctly applied to the driver. When opening the driver configurtion the settings are always overwritten with the Defaults.

Description

When creating new straton projects or changing the communication parameters in the zenon logic runtime settings, this settings are not correctly applied to the driver. When opening the driver configurtion the settings are always overwritten with the Defaults.

Solution

An issue has been addressed in the serialisation of the driver settings

Issue Number: 24054
Fixed on Date: 27.2.2013
Versions: 7.10 0 BUILD 5560
    • Related Articles

    • zenon Changesets Excel

      Here, you can access a comprehensive list of changes across all maintained versions of the zenon Software Platform as Excel Worksheets. This includes both implemented bug-fixes and new features. Additionally, these lists are available in CSV format ...
    • zenon Changesets CSV

      Here, you can access a comprehensive list of changes across all maintained versions of the zenon Software Platform as Excel Worksheets. This includes both implemented bug-fixes and new features. Additionally, these lists are available in as Excel ...
    • Checklist: Driver(s) cannot establish a reliable communication

      Time estimate: 60 minutes Please go through all the points in the following checklist. If necessary, confirm with IT Department any information you cannot verify before contacting your local COPA-DATA Representative. Checklist usage: #. [Quick hints] ...
    • Checklist: The Logic Service to Service Engine connection does not work

      Time estimate:   30 minutes Please go through all the points in the following checklist. If necessary, confirm with IT Department any information you cannot verify before contacting your local COPA-DATA Representative. Screenshot and followed ...
    • Checklist: Communication to TwinCat via BeckhoffNG driver

      Time estimate: 30 minutes Please go through all the points in the following checklist. If necessary, confirm with IT Department any information you cannot verify before contacting your local COPA-DATA Representative. TwinCAT ADS communication library ...