Variable links in RGM are lost on "Workspace save as" when using binary storage
Summary
When using RGM with binary storage and variables linked at the recipe groups from different projects, the Project links are not correctly updated after executing a "Workspace save as", or after executing "replace project links". With Access DB storage for RGM the Project links are correctly updated.
Description
When using RGM with binary storage and variables linked at the recipe groups from different projects, the Project links are not correctly updated after executing a "Workspace save as", or after executing "replace project links". With Access DB storage for RGM the Project links are correctly updated.
Solution
An issue was addressed where the Project links for variables from different Projects used at Groups in recipe Group Manager with binary storage, were not correctly updated after a "Workspace save as". Now the Project links are also correctly updated when using binary storage, when the project ID changes on "Workspace save as".
Information
available from 6.51 SP0 build 19
Issue Number: 28129
Fixed on Date: 12.11.2012
Versions: 7.00 0 BUILD 6 | 6.51 0 BUILD 19
Related Articles
FAQ: Recipes in RGM cannot be edited / RGM incompatibility of recipes between different builds in version 8.20.
There was found an incompatibility in the Recipe Group Manager (RGM) in zenon 8.20 Build 70282, 79336, 80198, 80611 and 81129. An issue was detected which causes the RGM recipes of the affected builds to be no longer compatible with recipes stored ...
VSTA code is no longer executed in the runtime in project copies created through the "Workspace save as..." function
Summary After creating a copy of the workspace and all its projects using the function "workspace save as.." the VSTA code in the project copies is no longer executed in the runtime. The VSTA code in the original projects is still executed correctly ...
FAQ: It seems that sometimes not all variables are correctly written to the PLC by the RGM module, although the system driver variable states that the recipe was written successfully and the option "write synchronously" is active. How can this be?
When reading a RGM recipe immediately after writing a RGM recipe, with a driver that has the option "keep update list in memory" active, and recipe variables that have been read previously, it can happen that a read cycle is currently in progress, ...
Checklist: Workspace/Project cannot be created, loaded or backed up
Time estimate: 30 minutes Please go through all the points in the following checklist. If necessary, confirm with IT Department any information you cannot verify before contacting your local COPA-DATA Representative. Checklist usage: #. [Quick hints] ...
FAQ: Can I change the storage type for RGM in an existing Project? What do I need to consider? What are the benefits?
Summary Solution Yes, you can change the storage type in the Recipe Groups Manager module from Access DB to binary storage, or vice versa, also in existing projects. The first two steps are only required when your runtime has priority over RGM recipe ...