The system driver variable "wrong value for set value" is not always set in the runtime when entering an invalid value for a recipe variable of the Recipegroup Manager in the Recipegroup Manager screen
Summary
When entering an invalid value for a recipe variable in the Recipegroup Manager screen in the runtime using the current recipe value table, the system driver variable "wrong value for set value" is not set. When the value is changed in the legacy recipe value table, the system driver variable is set correctly.
Description
When entering an invalid value for a recipe variable in the Recipegroup Manager screen in the runtime using the current recipe value table, the system driver variable "wrong value for set value" is not set. When the value is changed in the legacy recipe value table, the system driver variable is set correctly.
Solution
An issue has been addressed in the runtime where invalid value input in the recipe value table did not trigger the "wrong value for set value" system driver variable.
Issue Number: 33343
Fixed on Date: 17.12.2015
Versions: 7.60 0 BUILD 36068
Related Articles
FAQ: When I activate the option "write synchronously" for the Recipegroup manager recipe, and I write the recipe, the recipe does not seem to be written properly and also the Service Engine does not close properly. Why is that?
When the option "write synchronously" is active at a recipe, when writing a recipe (sending values to the PLC) for each recipe variable a writing confirmation is requested to the driver. On a successfull write, the driver sends a writing confirmation ...
Recipe variables in the recipe value table in the Recipegroup Manager screen are not always correctly set invisible
Summary It can happen that Recipegroup Manager recipe variables are still displayed in the recipe value table in the Recipegroup Manager screen in the runtime, although the linked visiblity variable have an active limit with the invisible attribute ...
Under specific circumstances an incorrect value is displayed in the setvaluekbd keyboard screen in the runtime on entering a value for a Recipegroup Manager recipe variable.
Summary When entering a value for a recipe variable in the Recipegroup manager screen in the runtime using a keyboard screen, while unit switching is used, the suggested setpoint input value displayed in the keyboard screen may not be the correct ...
FAQ: It seems that sometimes not all variables are correctly written to the PLC by the RGM module, although the system driver variable states that the recipe was written successfully and the option "write synchronously" is active. How can this be?
When reading a RGM recipe immediately after writing a RGM recipe, with a driver that has the option "keep update list in memory" active, and recipe variables that have been read previously, it can happen that a read cycle is currently in progress, ...
Entering a value using a datatype specific keyboard in the Recipegroup Manager recipe value list allows direct editing of the value as well
Summary When using a datatype specific keyboard in the Recipegroup Manager screen in the runtime to set a value in the recipe list, the value can be entered in the keyboard but also directly in the recipe value list. Description When using a datatype ...