The connect to modem validation mechanism of zenon sets wrong SMSC number in the SIM card settings and sending of SMS is not possible over that SIM card.
Summary
If the field:"Number of SMS center" is empty, the connect to modem validation mechanism of zenon sets a wrong number in the SIM card settings and sending of SMS is not possible over that SIM Card.
Description
If the field:"Number of SMS center" is empty, the connect to modem validation mechanism of zenon sets a wrong number in the SIM card settings and sending of SMS is not possible over that SIM Card.
Solution
If the configured SMS center number is invalid, the SMSC number stored on the SIM card is used now for connect to modem validation mechanism of zenon. The validation of recipients telephone numbers fails now if the field:"Number of SMS center" is empty.
Information
The SMSC(Short Message Service Center) of a SIM card is called "Number of SMS center" in zenon, in the modem sofware(depends on the manufacturer) the SMSC is called "Service Centre Number", "Message Service Number", etc..
Issue Number: 29989
Fixed on Date: 8.5.2013
Versions: 7.11 0 BUILD 10238