The action for the Recipegroup Manager recipe variable may be reset under specific circumstances on saving the recipe
Summary
When saving a Recipegroup Manager recipe in the Recipegroup Manager screen in the runtime, with a recipe table that does not display the recipe action column, the Recipegroup Manage rmay reset the configured action for recipe variables to "no action"
Description
When saving a Recipegroup Manager recipe in the Recipegroup Manager screen in the runtime, with a recipe table that does not display the recipe action column, the Recipegroup Manage rmay reset the configured action for recipe variables to "no action"
Solution
An issue has been addressed in the Recipegroup Manager in the runtime where saving a recipe could reset the recipe action for recipe variables when the action column was not displayed in the recipe table. Now the recipe action is not modified when the recipe is saved and the recipe action column was not displayed.
Information
Issue Number: 34527
Fixed on Date: 16.6.2015
Versions: 7.20 0 BUILD 20544
Related Articles
FAQ: When I activate the option "write synchronously" for the Recipegroup manager recipe, and I write the recipe, the recipe does not seem to be written properly and also the Service Engine does not close properly. Why is that?
When the option "write synchronously" is active at a recipe, when writing a recipe (sending values to the PLC) for each recipe variable a writing confirmation is requested to the driver. On a successfull write, the driver sends a writing confirmation ...
Cancelling changing the action type of a recipe variable in a Recipegroup Manager recipe in the editor does not refresh the recipe under specific circumstances.
Summary When the action type for a recipe variable in a recipe of the Recipegroup Manager is changed to "link with variable" without linking a variable, the change is not accepted on clicking OK. When cancelling the change and reopening the recipe, ...
The defined keyboard screen for editing Recipegroup Manager recipe variable values, may not open in the runtime under specific circumstances.
Summary When a keyboard screen is linked to a recipe variable at the Recipegroup Manager in the editor, this keyboard screen may not open in the runtime when the new recipe value list is used and a multi-hierarchical project structure is used. With ...
The "time of last change" field of a Recipegroup Manager recipe is not correctly updated in the runtime under specific circumstances
Summary When using the Recipegroup Manager screen in the runtime with the new recipe value table, saving the recipe after making changes, does not correctly update the "time of last change" field. In the following situations, the "time of last ...
FAQ: It seems that sometimes not all variables are correctly written to the PLC by the RGM module, although the system driver variable states that the recipe was written successfully and the option "write synchronously" is active. How can this be?
When reading a RGM recipe immediately after writing a RGM recipe, with a driver that has the option "keep update list in memory" active, and recipe variables that have been read previously, it can happen that a read cycle is currently in progress, ...