linking variables Limit min/max values are set to 0 when releasing a new versioned recipe
Description
In Batch Control, the values of the variables
linked for minimum and maximum values are set to 0
when a new version of a recipe is released.
This behavior has now been corrected. The minimum and
maximum values are preserved as expected when the new version is released
To benefit from this fix:
- Update your zenon Software Platform to the latest build of zenon 8.20 or
higher.
Item ID: 251704
Version: 8.20 Build: 99641
Related Articles
linking variables Limit min/max values are set to 0 when releasing a new versioned recipe
Summary The new version will be created correctly . Description The new version will be created correctly . Information not available Issue Number: 251704 Fixed on Date: 28.4.2022 Versions: 10 0 BUILD 98635 | 8.20 0 BUILD 99641
Linking variables Limit min/max values in an operation are set to 0 after releasing the Master recipe.
Description In Batch Control, when a Master Recipe is released, the values of the variables linked in an operation for minimum and maximum values are set to 0. However, when the operation is released, the values of the linked variables are retained ...
FAQ: When I activate the option "write synchronously" for the Recipegroup manager recipe, and I write the recipe, the recipe does not seem to be written properly and also the Service Engine does not close properly. Why is that?
When the option "write synchronously" is active at a recipe, when writing a recipe (sending values to the PLC) for each recipe variable a writing confirmation is requested to the driver. On a successfull write, the driver sends a writing confirmation ...
FAQ: It seems that sometimes not all variables are correctly written to the PLC by the RGM module, although the system driver variable states that the recipe was written successfully and the option "write synchronously" is active. How can this be?
When reading a RGM recipe immediately after writing a RGM recipe, with a driver that has the option "keep update list in memory" active, and recipe variables that have been read previously, it can happen that a read cycle is currently in progress, ...
Copy and paste of values in the value column of the recipe table for recipe values is not always accepted after saving
Summary Under circmstances the changes to recipe values made in the recipe table of the Recipe Group Manager screen in the runtime, using either the default list or a format file of the report generator are not accepted when saving the recipe if the ...