In the Service Engine, data from already closed archives is written to the current, open archive capsule in the Historian.

This problem can occur:

  • By project reload.
  • If the PLC sends variable values with an external timestamp from the past. These values with a possibly very distant timestamp are saved in the current ARX file.


This problem has been fixed. Values that have already been archived and values with an external time stamp from a long time ago are no longer entered in the current ARX file.

To benefit from this fix:

  • Update your zenon Software Platform to the latest build of zenon 12 or higher.


Item ID: 269745
Version: 12.00 Build: 180966
    • Related Articles

    • zenon Changesets Excel

      Here, you can access a comprehensive list of changes across all maintained versions of the zenon Software Platform as Excel Worksheets. This includes both implemented bug-fixes and new features. Additionally, these lists are available in CSV format ...
    • zenon Changesets CSV

      Here, you can access a comprehensive list of changes across all maintained versions of the zenon Software Platform as Excel Worksheets. This includes both implemented bug-fixes and new features. Additionally, these lists are available in as Excel ...
    • FAQ: Historian configuration general recommendations

      1. Recommendation on hardware: Storage Memory CPU - SSD (Solid-State Drive). - Disk space capacity as detailed in the attached Excel sheet outputs. - RAM required to load the archive data is about 4 times greater the size of the respective ARX files. ...
    • Historian: At redundancy switch old value may be written again in new capsule

      Description In the Historian, when redundancy is triggered, values that are already contained in an archive capsule on server 1 are written again to a new archive capsule on server 2 with the same time stamps. These values should not be written to ...
    • FAQ: What is the time zone and time format used in zenon Software Platform products and what needs to be considered?

      When you ask someone what the time is, they'll usually be able to tell you. But when you ask them what date and time sunrise was yesterday in a different country on a different continent, in a different hemisphere it gets less easy. Terms like GMT ...