AccessOPCUA: Changes and enhancements in the OPC UA server of the process gateway

AccessOPCUA: Changes and enhancements in the OPC UA server of the process gateway

Summary

below is a summary of the changes: - Update of the Ansi C stack to version 1.03.341 - Adoptions to the COPA-DATA OPC UA server stack and OPC UA server implementations to acommodate the Ansi C stack update - New option to allow configuration of arbitrary variables from base archives and aggregating archives of the zenon historian, including MIN, MAX, AVG and SUM for HistoryReadRaw requests - Configured variables in the OPC UA address space use namespace index 2 - Without any explicit confiugration of variables in the OPC UA process gateway configuration, the OPC UA address space is now empty and not filled with all variables of all projects in the runtime

Description

below is a summary of the changes: - Update of the Ansi C stack to version 1.03.341 - Adoptions to the COPA-DATA OPC UA server stack and OPC UA server implementations to acommodate the Ansi C stack update - New option to allow configuration of arbitrary variables from base archives and aggregating archives of the zenon historian, including MIN, MAX, AVG and SUM for HistoryReadRaw requests - Configured variables in the OPC UA address space use namespace index 2 - Without any explicit confiugration of variables in the OPC UA process gateway configuration, the OPC UA address space is now empty and not filled with all variables of all projects in the runtime

Issue Number: 45624
Fixed on Date: 5.3.2018
Versions: 7.50 0 BUILD 45624 | 7.60 0 BUILD 45859
    • Related Articles

    • How to setup the zenon OPC UA Process Gateway with a CA-signed certificate

      This article describes how to create a certificate signed by a Certificate Authority (CA) for using it with the zenon OPC UA Process Gateway. For general information about certificate usage for OPC UA security, please refer to the article How to use ...
    • How to setup the zenon OPC UA Process Gateway with a self-signed certificate

      This article describes how to create a self-signed certificate for using it with the zenon OPC UA Process Gateway. For general information about certificate usage for OPC UA security, please refer to the article How to use certificates for OPC UA ...
    • How to use certificates for OPC UA security

      This article provides an overview of how to use X.509 certificates in order to enable OPC UA security. It links to further how-tos that explicitly describe the necessary steps to create certificates and add them to the configuration of either the OPC ...
    • FAQ: How can I browse an OPC UA Server using the zenon OPC UA Client Driver?

      Go to Drivers > New Driver Create a Driver of Type "OPC UA Client Driver" Open the Driver Configuration Go to "Connections" Create a new Connection Enter your Discovery URL Enter your Server URL manually or click the 3 dots to browse the Discovery ...
    • AccessOPCUA: Support for external OPC UA Data Model

      Summary The AccessOPCUA Process Gateway now also supports external OPC UA information models. The following enhancements have been implemented for this purpose: Reload supports customized OPC UA information models without interrupting communication ...